Adaptec Scsi Controller Configuration Error 03
log in with your existing support account. Username Password Forgot your username or password? Support Home Answers Ask a Question Your Account Account Overview Support History Account Settings Notifications "SCSI Controller Configuration Error 02" message appears at POST Answer ID 3922 | Published 07/18/2002 03:30 PM | Updated 02/04/2010 07:04 AM When the Adaptec SCSI Select Utility loads, the following message appears on the screen : SCSI Controller Configuration Error 02 This information applies to the following Operating System(s): - This information is not Operating System specific Basically, the card detected a configuration error, most likely on the SCSI bus. It is possible that the termination on the SCSI bus or the cable itself might have gotten defective. For test, please try to disconnect all SCSI devices on the card. Boot the system and see if you still get the error. Most of the times, this error message will appear when connecting an HVD (High Voltage Differential) SCSI device to the Low Voltage Differential (LVD) SCSI card. Ultra160 SCSI cards only support the use of Low Voltage Differential (LVD) and Single-Ended (SE) devices. CAUTION! Connecting HVD devices to a non-HVD SCSI controller may damage both the device and the SCSI controller. Determine if your device(s) being attached is a HVD device. Check for any markings on the device, typically near the SCSI connector that may indicate HVD or LVD/SE. However do not trust these marking completely, double check the type of device inside the unit. Although the external case may be marked as LVD, it is still possible the internal device may still be an HVD device. The manufacuter of the device(s) should be contacted, if reviewing the documentation or visiting the manufacturers web shed light on the interface style the device is using. Note: When using a HVD (High Voltage Differential) device, a HVD SCSI card must be used. The correct Adaptec HVD SCSI product, would be an AHA-2944UW. This HVD SCSI card, designed specifically to work with HVD SCSI devices only. Was this answer helpful? Yes No Your rating has been submitted, please tell us how we can make this answer more useful. Email *Required Your Feedback *Required Answers others
to default, but still have the same error on POST. Can it be a problem with the B channel? Answer http://ask.adaptec.com/app/answers/detail/a_id/3922/~/scsi-controller-configuration-error-02-message-appears-at-post There is no issue with the on-board SCSI B channel. For some reason, the on-board Adaptec SCSI Host Controller termination is disabled, please check and make sure jumper JPA2 https://www.supermicro.com/support/faqs/faq.cfm?faq=3891 is open to enable termination. Was this FAQ helpful? YES NO Enter Comments Below:Note: Your comments/feedback should be limited to this FAQ only. For technical support, please send an email to support@supermicro.com. Enter your email address below if you'd like a technical support staff to reply: Please type what you see: FAQ Stats FAQ ID Related Category / Keyword Date Posted Code 3891 BIOS: - AMI BIOS- Award BIOS- Phoenix BIOS Storage: - Adaptec AIC-7902 U320 SCSI- U320 SCSI Controllers 10/29/05 DL Print Answer
Start here for a quick overview of the site Help Center Detailed answers to any questions you might have Meta Discuss the http://serverfault.com/questions/195682/how-to-resolve-dell-poweredge-2850-boot-error workings and policies of this site About Us Learn more about Stack Overflow the company Business Learn more about hiring developers or posting ads with us Server Fault Questions Tags Users Badges Unanswered Ask Question _ Server Fault is a question and answer site for system and network administrators. Join them; it only takes a minute: Sign up Here's adaptec scsi how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the top How to resolve Dell Poweredge 2850 boot error up vote 0 down vote favorite In the POST sequence I get the error message 29160 at slot 2 0A:03:00 scsi controller config error. 02 I removed the CDrom drive, adaptec scsi controller could this be the cause? Where do I look to find out whats going on? dell-poweredge share|improve this question asked Oct 28 '10 at 7:20 Saul 1792816 add a comment| 1 Answer 1 active oldest votes up vote 1 down vote accepted From Adaptec, hope it helps; SCSI Controller Configuration Error 02 This applies to the following Product(s): Adaptec SCSI Card 39160, Adaptec SCSI Card 29160, Adaptec SCSI Card 29160LP, Adaptec SCSI Card 29160N, Adaptec SCSI Card 19160 Answer This error message will appear when connecting an HVD (High Voltage Differential) SCSI device to the Low Voltage Differential (LVD) SCSI card. Ultra 160 SCSI cards only support the use of Low Voltage Differential (LVD) and Single-Ended (SE) devices. CAUTION! Connecting HVD devices to a non-HVD SCSI controller may damage both the device and the SCSI controller. Determine if your device(s) being attached is a HVD device. Check for any markings on the device, typically near the SCSI connector that may indicate HVD or LVD/SE. However do not trust these marking completely, double check the type of
be down. Please try the request again. Your cache administrator is webmaster. Generated Fri, 30 Sep 2016 02:24:34 GMT by s_hv977 (squid/3.5.20)