Adapter Error With Id 3074feb7
Technology and Trends Enterprise Architecture and EAI ERP Hardware IT Management and Strategy Java Knowledge Management Linux Networking Oracle PeopleSoft Project and Portfolio Management SAP SCM Security Siebel Storage UNIX Visual Basic Web Design and Development Windows < Back CHOOSE A DISCUSSION GROUP Research Directory TOPICS Database Hardware Networking SAP Security Web Design MEMBERS Paul_Pedant MarkDeVries DACREE Inside-ERP MacProTX VoIP_News Inside-CRM I_am_the_dragon PCMag maxwellarnold Michael Meyers-Jouan TerryCurran Chris_Day Andrew.S.Baker Richard JoeTorre bracke Ramnath.Awate DukeGanote Locutus Nikki Klein Dennis Stevenson AbhaiTripathi Craig Borysowich Clinton Jones bluesguyAZ59 iudithm mircea_luca Adrian_Grigoriu blrvenkat COMPANIES ZOHO Corporation Imation RSA Conference Apperian View All Topics View All Members View All Companies Toolbox for IT Topics UNIX Groups Ask a New Question IBM AIX The IBM AIX group is your premier resource for objective technical discussion and peer-to-peer support on IBM AIX. Home | Invite Peers | More UNIX Groups Your account is ready. You're now being signed in. Solve problems - It's Free Create your account in seconds E-mail address is taken If this is your account,sign in here Email address Username Between 5 and 30 characters. No spaces please The Profile Name is already in use Password Notify me of new activity in this group: Real Time Daily Never Keep me informed of the latest: White Papers Newsletter Jobs By clicking "Join Now", you agree to Toolbox for Technology terms of use, and have read and understand our privacy policy. 3074FEB7 ADAPTER ERROR Ayman Zoheiry asked Nov 20, 2012 | Replies (6) Dears, I have one node in a hacmp environment and got this error in errpt 3074FEB7 3074FEB7 1120102512 T H fscsi0 ADAPTER ERROR 3074FEB7 1120102512 T H fscsi0 ADAPTER ERROR 3074FEB7 1120102512 T H fscsi1 ADAPTER ERROR 3074FEB7 1120102512 T H fscsi1 ADAPTER ERROR 3074FEB7 1120102512 T H fscsi1 ADAPTER ERROR 3074FEB7 1120102512 T H fscsi1 ADAPTER ERROR 3074FEB7 1120102512 T H fscsi1 ADAPTER ERROR What I don't understand that it outputs lot lot lot lot of error like every 2 seconds and every a minute it gave: D1E21BA3 1120102312 I S errdemon LOG FILE EXPANDED TO REQUESTED SIZE And this is for sure because of the big errors he got!! Please advice!! What is the problem as I searched and didn't find any solution!! it's a cr
few RS/6000s that have been humming along problem free for a while. They are HACMP clusters with two 6228 cards each (fcs0 and fcs01) attached to an EMC Symetrix storage array. Recently the storage group asked us to install the Emc ECC software on our boxes so they can monitor EMC stats. Since that time these boxes have been generating generic errors: 3074FEB7 1102020003 T H fscsi0 ADAPTER ERROR LABEL: FSCSI_ERR4 IDENTIFIER: 3074FEB7 Date/Time: Sun Nov 2 02:00:59 Sequence Number: 6978 http://unix.ittoolbox.com/groups/technical-functional/ibm-aix-l/3074feb7-adapter-error-5012812 Machine Id: 000914314C00 Class: H Type: TEMP Resource Name: fscsi0 Resource Class: driver Resource Type: efscsi ... Thread Tools Show Printable Version Email this Page… Subscribe to this Thread… Display Linear Mode Switch to Hybrid Mode Switch to Threaded Mode November 17th,03:44 PM #1 IBM 6228 Fiber Cards generating errors I have a few RS/6000s that have been humming along http://www.justskins.com/forums/ibm-6228-fiber-cards-185794.html problem free for a while. They are HACMP clusters with two 6228 cards each (fcs0 and fcs01) attached to an EMC Symetrix storage array. Recently the storage group asked us to install the Emc ECC software on our boxes so they can monitor EMC stats. Since that time these boxes have been generating generic errors: 3074FEB7 1102020003 T H fscsi0 ADAPTER ERROR LABEL: FSCSI_ERR4 IDENTIFIER: 3074FEB7 Date/Time: Sun Nov 2 02:00:59 Sequence Number: 6978 Machine Id: 000914314C00 Class: H Type: TEMP Resource Name: fscsi0 Resource Class: driver Resource Type: efscsi Location: 20-58-01 Description ADAPTER ERROR Probable Causes ADAPTER HARDWARE OR CABLE ADAPTER MICROCODE FIBRE CHANNEL SWITCH OR FC-AL HUB Failure Causes ADAPTER CABLES AND CONNECTIONS DEVICE Recommended Actions PERFORM PROBLEM DETERMINATION PROCEDURES CHECK CABLES AND THEIR CONNECTIONS VERIFY DEVICE CONFIGURATION Detail Data SENSE DATA 0000 0000 0000 002A 0000 0000 0200 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0063 0813 0000 0000 0063 2313 7D7B 02A6 0000 0000 0000 0000 0000 0000 4814 4D
from GoogleSign inHidden fieldsBooksbooks.google.com - This IBM® Redbooks® publication describes the new IBM i Midrange External Storage solutions available for IBM https://books.google.com/books?id=Fb26AgAAQBAJ&pg=PA394&lpg=PA394&dq=adapter+error+with+id+3074feb7&source=bl&ots=cvZIj4Fh5m&sig=Nwd-s7d7NBk7LcGgFyiroo_duf0&hl=en&sa=X&ved=0ahUKEwjc9Zj9iKrPAhVJ-mMKHWa-CS8Q6AEISDAF POWERTM Systems POWER6TM servers with IBM i being a client of IBM Virtual I/O Server (VIOS). It introduces the VIOS http://www.dbforums.com/showthread.php?1215445-AIX-error-log virtualization concepts and IBM DS Midrange External Storage Systems architecture...https://books.google.com/books/about/IBM_i_and_Midrange_External_Storage.html?id=Fb26AgAAQBAJ&utm_source=gb-gplus-shareIBM i and Midrange External StorageMy libraryHelpAdvanced Book SearchBuy eBook - adapter error $0.00Get this book in printAmazon.com - $56.25Barnes&Noble.comBooks-A-MillionIndieBoundFind in a libraryAll sellers»IBM i and Midrange External StorageHernando Bedoya, Ingo Dimmer, Jana Jamsek, Thomas Penzkofer, IBM RedbooksIBM Redbooks, Jul 7, 2009 - Computers - 456 pages 0 Reviewshttps://books.google.com/books/about/IBM_i_and_Midrange_External_Storage.html?id=Fb26AgAAQBAJThis IBM® Redbooks® publication describes the adapter error with new IBM i Midrange External Storage solutions available for IBM POWERTM Systems POWER6TM servers with IBM i being a client of IBM Virtual I/O Server (VIOS). It introduces the VIOS virtualization concepts and IBM DS Midrange External Storage Systems architecture of the supported models DS3400, DS4700, DS4800, and DS5000, discusses planning and sizing for IBM i Midrange External Storage, and provides detailed implementation procedures including IBM DS Midrange Storage Copy Services. Finally, it provides monitoring, maintenance, and troubleshooting hints for the triumvirate of IBM i, VIOS, and IBM DS Midrange External Storage.The information provided by this book will help customers, business partners, and IBM service professionals with planning and implementing IBM i Midrange External Storage solutions. Preview this book &r
visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. Results 1 to 6 of 6 Thread: AIX error log Tweet Thread Tools Show Printable Version Subscribe to this Thread… Search Thread Advanced Search Display Linear Mode Switch to Hybrid Mode Switch to Threaded Mode 04-12-06,11:41 #1 okdalst View Profile View Forum Posts Registered User Join Date Mar 2006 Posts 6 Unanswered: AIX error log Hi, I need help to get a script to extract the permanent hardware errors from the error log in AIX and then ignore ones that are more than 30 days old. I am redirecting errpt to a file called error_file and then doing awk -f test_script error_file. where test_script contains: #!/bin/ksh $4 ~ /H/ { print $1, $2, $3, $4, $5, $6, $7, $8, $9, $10 } so I get a summary of the hardware errors.But how can I get only ones newer than 30 days old? thanks in advance for help... Reply With Quote 04-26-06,13:20 #2 okdalst View Profile View Forum Posts Registered User Join Date Mar 2006 Posts 6 Let me rephrase all this. Does anybody know how I could extract the permanent hardware errors in the error log that are less than a week, or say a month old??? Reply With Quote 04-26-06,14:34 #3 LKBrwn_DBA View Profile View Forum Posts Registered User Join Date Jun 2003 Location West Palm Beach, FL Posts 2,713 Post and example of the output from your script. The person who says it can't be done should not interrupt the person doing it. -- Chinese proverb Reply With Quote 04-26-06,14:40 #4 okdalst View Profile View Forum Posts Registered User Join Date Mar 2006 Posts 6 Here is what I get from my script: The following hardware errors are in the error log today ************************************************** ****** 0D09B489 0227123906 P H hdisk2 POLLED STATUS FAILURE 3074FEB7 0227123906 T H fscsi1 ADAPTER ERROR 3074FEB7 0227123906 T H fscsi1 ADAPTER ERROR 3074FEB7 0227123906 T H fscsi1 ADAPTER ERROR 3074FEB7 0227123906 T H fscsi1 ADAPTER ERROR B8113DD1 0227123706 T H fcs1 LINK ERROR but these are all old errors that have been there for a while. Is there a way to take apart that date field and just show new errors or nothing, like a comment saying no new errors today etc? Reply With Quote 05-03-06,08:04 #5 pdreyer View Profile View Forum Posts Re