An Internal Recognizer Error Has Occurred Dragon Naturallyspeaking
Speaking / An internal recognizer error has occurredProblemIn Dragon Naturally Speaking, on startup you get the message:"An internal recognizer error has occurred. NaturallySpeaking may be in an unstable state, so you should save your work immediately and then close and restart the program."SolutionFix the corrupt Dragon profile.Share this:PrintEmailFacebookRedditTwitterGoogle13 Responses to An internal recognizer error has occurred Reply Anonymous June 18, 2010 at 12:41 excellent, they way explained. well done Reply Anonymous July 14, 2010 at 16:19 This was unbelievably helpful! I have Dragon Naturally Speaking 10.1, and even calls to tech support didn't solve the problem. These instructions were fantastic… Thanks so much! Reply Two Peas in a pod! September 7, 2010 at 20:23 Fantastic! that worked 🙂 Reply Anonymous January 21, 2011 at 15:54 Technical issues of any kind throw me, but your instructions were clear enough (even) for me to follow and it worked! I can't thank you enough! Reply Anonymous January 25, 2011 at 18:18 This worked for me! Using Dragon Medical v10.00. Thank you!!! Reply Freddie February 5, 2011 at 19:47 This was the best support I have ever received. thank you it worked like a charm keep up the good work. Reply bruno del priore August 1, 2011 at 08:42 whot about mackeeper Reply Carl Norton August 1, 2011 at 09:04 If you are looking to remove MacKeeper, please use this link: Uninstall MacKeeper - [Fix-KB] Reply Anonymous January 17, 2012 at 17:44 Thanks! Reply Kevin October 5, 2012 at 16:37 Worked like a charm. Thanks Carl Reply Anonymous May 11, 2013 at 15:26 Awesome instructions.. Worked perfectly. Thanks for posting! Reply Felix November 4, 2014 at 16:02 Awesome worked great. The only thing i would put in there is you click on Dragon and click on manage users from there. But everything else was easy. Reply Robin April 22, 2015 at 21:49 I actually tried recovering the user profile several times but the prob
product, category, keywords, or phrases. Advanced Search Search terms Screen Reader users press enter to Limit by product. Limit by product This button does not work with screen readers. Please use the previous link instead. Select a product Screen Reader users press enter to Limit by category. Limit by category This button does not work with screen readers. Please use the previous link instead. Select a category Sort by Default Summary New or http://www.fixkb.com/2010/05/internal-recognizer-error-has-occurred.html Updated Description Date Updated Direction Ascending Descending Search Tips Find the answer to your question Search filters applied "An internal recognizer error has occurred" error message may appear when performing "Special" training or creating a digital recorder user Answer ID 5661 | Published 08/15/2008 12:00 AM | Updated 04/16/2010 04:34 PM "An internal http://nuance.custhelp.com/app/answers/detail/a_id/5661/~/an-internal-recognizer-error-has-occurred-error-message-may-appear-when recognizer error has occurred" error message may appear when performing "Special" training or creating a digital recorder user Problem: When performing "Special" training or creating a digital recorder user, Dragon may return the following error message: An internal recognizer error has occurred. NaturallySpeaking may be in an unstable state, so you should save your work immediately and then close and restart the program. Cause: When using the new "Special" training selection or when creating a digital recorder user, a temporary file is created which is used for adapting the user profile . An error may be returned if the Windows user is unable to write this location. Note: It is common that restricted users are not able to write to this location. Solution: In order for users to be able to perform "Special" training or create a digital recorder user, they must have Read/Write permissions to the location listed below. Windows 2000/XP/2003: C:\Documents and Settings\All Users\Application Data\Nuance\NaturallySpeakin
product, category, keywords, or phrases. Advanced Search Search terms Screen Reader users press enter to Limit by product. Limit by product This button does not work with screen readers. Please use the previous link instead. Select a product Screen Reader users press enter http://nuance.custhelp.com/app/answers/detail/a_id/2544/~/unable-to-open-a-user-in-dragon-naturallyspeaking to Limit by category. Limit by category This button does not work with screen readers. https://isupportcontent.nuance.com/healthcare/16500/16543/DragonERRORmatrix.html Please use the previous link instead. Select a category Sort by Default Summary New or Updated Description Date Updated Direction Ascending Descending Search Tips Find the answer to your question Search filters applied Unable to open a user in Dragon NaturallySpeaking Answer ID 2544 | Published 07/09/2002 12:00 AM | Updated 08/17/2011 03:30 PM Unable to open a user in Dragon an internal NaturallySpeaking Problem: When opening a user in Dragon NaturallySpeaking, the selected user may not open or one of the following error messages may appear: "SDAPI Error" "Signal Processing Error" "The vocabulary you have chosen General - Large is incompatible or invalid" "Internal Recognizer Error" "E_Fail" Restoring a good copy of the user's speech files will often resolve this issue. Cause: The user cannot load due to Speech File corruption. The Speech File corruption can be caused by an internal recognizer a number of things, including aggressive anti-virus software settings, power surges occurring as Dragon saves the speech files or low memory resources. Solution: Restoring the user files often resolves this issue: If the automatic restoreprocess fails witihin Dragon NaturallySpeaking, pleasefollow the steps forthe manual restore listed below. If the user profile is still experiencing problems after attempting a manual restore, please create a new user as the user profile and its back-up are corrupted. If the automatic restoreprocess works but the user profile still cannot be opened, it is not necessary to attempt a manual restore. Please create a new user as the user profile and its back-up are corrupted. Please follow the steps below to automatically restore the user file for version 7, 8,9, 10, 11: (without Roaming enabled) Launch Dragon NaturallySpeaking. From the Dragon Bar click "NaturallySpeaking > Manage Users" (in Dragon 11, click "Profile > Manage User Profiles"). Select the user file giving the error so it is highlighted. Click the "Advanced" button. Click on "Restore". A user named "(USER-NAME) Restored1" will be created. Close out of Manage Users. From the Dragon Bar click "NaturallySpeaking > Open Users" (in Dragon 11, click "Profile > Open User Profile"). Select the restored user. Click on "Open". The User should now load successfully. Please follow the steps below to manually restore the user file for v
ERROR Matrix below. Currently, there are two (2) expandable tables: General ERRORS - contains errors that are not related to profile corruption or recognition accuracy issues Profile Corruption ERRORS Search for ERRORS To search for specific errors within the ERROR Matrix, either click the table links above to jump directly to an individual table and manually review the content...or, simply use your browser's Find function to search this page for specific ERROR strings. Additional errors will be continually added. The existing ERRORS presented in the individual tables below will be updated to include workarounds and solutions as they become available. Please revisit this solution periodically to check for changes to these ERRORS. Expandable Tables The tables within this solution have rows containing four (4) sections per row: ERROR Description STATUS WORKAROUND Three (3) of the sections for each row are expandable as indicated above. Each expandable section can be expanded and collapsed to display selected detail for specific topics or ERRORs. IMPORTANT: Click the section's plus buttons to expand and display additional information about a topic within each row. Click the section's minus buttons to collapse the information. In addition, at the top-right of each table, click the Expand All link to expand all details for all tables on this page, and click the Collapse All link to minimize all of the details. The following table describes the columns and their expandable sections presented in the error tables within this document: Column Section (expandable) Disposition Function ERROR and Description ERROR Provides the searchable ERROR syntax. Description Brief Description of the associated issue. Product(s) Version(s) Affected Provides the known, affected Dragon Medical Products and their versions. Status / Workaround STATUS SOLVED Information is provided that permanently solves this issue. SOLUTION PENDING A permanent solution is not currently available. WORKAROUND Yes Workarounds are available . No No workarounds will be issued. Not Currently A workaround is not currently available. Notes: Topics with table links to iSupport solutions marked "Internal" will need to be addressed by Tec