Application Virtualization Error The System Is Too Busy
request or is itApp-V? Is it the “System” that’s really too busy to complete the request or is itApp-V? August 3, 2011 madvirtualizer Leave a comment Go to comments Chances are, if you have deployed App-V in a large-scale TS/RDS environment, you may have come across this intermittent error message: Application Virtualization Error - The System is too busy to complete the request. If the problem persists, please report it to your system administrator Sometimes it is followed by a specific error code. Error code 1690140A-200001CD The error may even follow another error such as: The Application Virtualization client could not be started. The Application Virtualization Service is not running. Report the following error code to your System Administrator: Error Code: 4602847-0FA10612-00006003. Normally, when we get messages about the "System” being too busy to complete the request it is misleading. What is really too busy to complete the request is the App-V front end component. When The SFTTRAY command launches, if it sees another instance of itself running, it tries to pass off whatever it was supposed to do to the existing sfttray process. If it sees that other instance but the handoff times out because the other instance isn’t responsive, it will return with this message. The error message really is telling you that SFTTRAY (or another front end component such as VAPPLAUNCHER or SFTDDE) is unable to complete the request because an App-V client component is too busy to complete the request. There could be many underlying causes to this resulting from the SFTLIST.EXE (client service) being too busy or even the desktop configuration controller component (SFTDCC.EXE) not being responsive. If this is tied to a global DC refresh, or periodic DC refresh we could have a known issue with SFTDCC not releasing handles. The 6th Hotfix for 4.6.0 addresses this and is available: http://support.microsoft.com/kb/2517187 RTSPS Channels We recently also came across another cause of this issue and it is outlined here: http://blogs.technet.com/b/appv/archive/2011/07/28/clients-encounter-error-code-xxxxxx0a-200001cd-when-streaming-rtsps-in-microsoft-app-v.aspx In this case, the RTSPS protocol was the culprit. RTSPS (RTSP over SSL) is limited to 255 channels and each package takes two channels. If the total number of channels exceeds this value then the error above is generated. To resolve the issue, decrease the maximum number of channels in use at any given time
How to fix the “application took too long to be ready to interact with the user” 04-000041E error ★★★★★★★★★★★★★★★ J.C. HornbeckMay 17, 20112 0 0 0 Hi everyone, John Behneman here, I’m a Support Engineer on the System Center Virtualization team and I wanted to show you how to quickly and easily fix an issue you might see with some Java based applications when sequenced (virtualized) with Microsoft App-V. So let’s say you sequence a Java based application like Libre Office, for example. When you try to launch the application, the application does initially try to launch but you notice the https://madvirtualizer.wordpress.com/2011/08/03/is-it-the-%E2%80%9Csystem%E2%80%9D-that%E2%80%99s-really-too-busy-to-complete-the-request-or-is-it-app-v/ launch indicator shows 100% and just sits there for around 10 minutes or so: Finally after approximately 10 minutes the launch fails and the application terminates with the following error message: The Application Virtualization Client could not launch
board cookies • All times are UTC + 1 hour [ DST ] Powered by phpBB Forum Software © phpBB Group phpBB Metro Theme by PixelGoose Studio
Data Management Pega Mobility User Interface Products Accessibility Framework Autonomic Event Services (AES) Business Intelligence Exchange (BIX) Decision Strategy Manager Pega Cloud Pega Cloud Collaboration Services PegaSurvey Pega Web Mashup System Management Application (SMA) Legacy Chordiant PegaDISTRIBUTION Manager PegaWORKS Products Predictive Analytics Director for PRPC Applications Pega Customer Service Pega Field Service Pega Marketing Pega Sales Automation Applications by Industry Communications & Media Energy Financial Services Government Healthcare Insurance Life Sciences Manufacturing & High Technology Academy My Self-Study My Classroom Course Catalog New Pega 7.2 Core Curriculum Pega PASS Subscriptions My Certifications Verify Certification Learning Paths Contact Pega Academy Support Pega Support Product Support Community Pega Upgrade Center Downloads Pega 7 Personal Edition Licensed Software Pega 7 Update Software Hotfix Catalog Deployments & Upgrades Deployment Guides Pega 7 Platform Support Guide PRPC 5 & 6 Platform Support Guide Online Help Systems Large File Transfer Application Communities Customers Customer Success Program Pega Can Awards Customer Advisory Board Resources PegaTube Pega TechTalk Pega Exchange Business Architect Central Pega Sites Search form Search Sign InContact Us Sign In × Status message You must login to access this content. Email: Password: Sign In Forgot password?Don't have an account?Create one US: +1 (617) 374 9600 UK: +44(0) 118 9591150 Australia: +61 2 9581 7000 Contact Us Privacy & Security Terms of Use Trademarks ©2016 Pegasystems Inc.