Automation Error Not Enough Storage
Contents |
One games Xbox 360 games PC automation error library not registered games Windows games Windows phone games Entertainment All automation error vba Entertainment Movies & TV Music Business & Education Business Students & automation error vb6 educators Developers Sale Sale Find a store Gift cards Products Software & services Windows Office Free downloads & security
Automation Error The Object Invoked Disconnected From Its Clients
Internet Explorer Microsoft Edge Skype OneNote OneDrive Microsoft Health MSN Bing Microsoft Groove Microsoft Movies & TV Devices & Xbox All Microsoft devices Microsoft Surface All Windows PCs & tablets PC accessories Xbox & games Microsoft Band Microsoft automation error the specified module cannot be found Lumia All Windows phones Microsoft HoloLens For business Cloud Platform Microsoft Azure Microsoft Dynamics Windows for business Office for business Skype for business Surface for business Enterprise solutions Small business solutions Find a solutions provider Volume Licensing For developers & IT pros Develop Windows apps Microsoft Azure MSDN TechNet Visual Studio For students & educators Office for students OneNote in classroom Shop PCs & tablets perfect for students Microsoft in Education Support Sign in Cart Cart Javascript is disabled Please enable javascript and refresh the page Cookies are disabled Please enable cookies and refresh the page CV: {{ getCv() }} English (United States) Terms of use Privacy & cookies Trademarks © 2016 Microsoft
12, 200912 0 0 0 I have come across a few issues whereI have seen the above error. Below are two scenarios of the issue and the symptoms thatI've noticed during that run-time error '-2147 automation error time. · Domain Workstations going into
Runtime Error 440 Automation Error
a state where they are unable to access resources over the network. · Member Servers unable to access network resources
Automation Error The System Cannot Find The File Specified
and stop allowing domain users to login. **In both the above scenarios, the issue seemed to get fixed for some time if the computer was Rebooted. Further investigations show a common set https://support.microsoft.com/en-us/kb/106167 of errors being reported on these problem computers. 5719 NETLOGONThis computer was not able to set up a secure session with a domaincontroller in domain %Domainname% due to the following: Not enough storage is available to process this command. This may lead to authentication problems. Make sure that thiscomputer is connected to the network. 40960 LSASRVThe Security System detected an authentication error for theserver cifs/hostname.domain,com. The https://blogs.technet.microsoft.com/abizerh/2009/07/12/troubleshooting-the-error-not-enough-storage-is-available-to-complete-this-operation/ failure code from authentication protocol Kerberoswas "There are currently no logon servers available to service the logon request. (0xc000005e)". 1053 UserenvWindows cannot determine the user or computer name. (Not enough storage is available to complete this operation. ). Group Policy processing aborted. Though this errors clearly says "Not enough storage.." you may still see enough available RAM and good amount of free space on the hard drive, on that problemcomputer. So why does it still say "Not enough storage is available to complete this operation"? What I understood from this error was that a RESTRICTED amount of MEMORY allocated for particular type of OS RESOURCE, has got EXHAUSTED. In both the cases above, the resource type that was getting exhausted or causing other resources to be exhausted was a HANDLE. A Handle is an OS object used to get a reference of another object (like File, registry, port etc.). It’s using these handles that a process will work with open files, read registry keys or work with a network port. In both the above scenarios, we saw a process (Non-Microsoft) consuming large amount of Handles. You can view the handles owned by different processes
Pack Deployment Linux Patch Management Software Deployment Windows software Deployment Mac software Deployment Self Service Portal Mobile Device Management Mobile App Management BYOD IT Asset Management Software https://www.manageengine.com/products/desktop-central/agent_installation_failure_storage.html Metering Software License Compliance Prohibited Software Block Application Remote Control USB Device http://stackoverflow.com/questions/548971/win32exception-not-enough-storage-is-available-to-process-this-command Management Power Management Custom Script Configurations Windows Configurations Mac Configurations Windows Tools Reports Active Directory Reports User Logon Reports Role Based Administration Two Factor Authentication Supported Platforms Windows Mac Linux Mobile App Related Products »Desktop Central MSP »Mobile Device Manager Plus »Patch Connect Plus »OS Deployer »Free automation error Windows Tools Awards "Not enough storage available to process this command" Problem You see the error message, 'Not enough storage available to process this command' on the screen, when the following operations fail: Agent/Distribution server installation Patch and asset scanning Remote control Cause You see this error if the IRPStackSize registry entry on the client computer is set too automation error the low. Resolution You can resolve this issue by increasing the IRPStackSize registry in the client computer in which the error occured. To increase the IRPStackSize registry, follow the steps given below: Click start>Run Enter regedit Click OK Expand HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\lanmanserver\parameters Double-click parameters Right-click on the IRPStackSize and click Modify Note: If the IRPStackSize entry is not present in this subkey, follow the steps given below to create it: Click Edit Point to New Click DWORD Value Enter a name for the IRPStackSize value Press Enter Note: Enter a name for the IRPStackSize value exactly as it appears. The value name is case sensitive. In the Value data field, enter a value larger than the original value Click OK For more details, see Description of the IRPStackSize parameter in Windows 2000, in Windows XP, and in Windows Server 2003 Applies to: Agent/Distribution server Installation Failure, Desktop Central Agent/Distribution server Installation, Patch Scan Failure, Asset Scan Failure, Remote Control Failure Keywords: Agent/Distribution server Installation, Desktop Central Agent/Distribution server Installation Failure, Installation Failure, Asset Scan Fails, Patch Scan Fails, R
here for a quick overview of the site Help Center Detailed answers to any questions you might have Meta Discuss the workings and policies of this site About Us Learn more about Stack Overflow the company Business Learn more about hiring developers or posting ads with us Stack Overflow Questions Jobs Documentation Tags Users Badges Ask Question x Dismiss Join the Stack Overflow Community Stack Overflow is a community of 4.7 million programmers, just like you, helping each other. Join them; it only takes a minute: Sign up Win32Exception Not enough storage is available to process this command up vote 9 down vote favorite 8 Through my automated crash collection for MaxTo I got the following crash report: V8.12.0.0 - System.ComponentModel.Win32Exception - :Void UpdateLayered():0 Version: MaxTo8.12.0.0 Exception: System.ComponentModel.Win32Exception Error message: Not enough storage is available to process this command Stack trace: at System.Windows.Forms.Form.UpdateLayered() at System.Windows.Forms.Form.OnHandleCreated(EventArgs e) at System.Windows.Forms.Control.WmCreate(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ScrollableControl.WndProc(Message& m) at System.Windows.Forms.ContainerControl.WndProc(Message& m) at System.Windows.Forms.Form.WmCreate(Message& m) at System.Windows.Forms.Form.WndProc(Message& m) at MaxTo.MainForm.WndProc(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) Another stacktrace: Version: MaxTo2009.9.0.0 Exception: System.ComponentModel.Win32Exception Error message: Not enough storage is available to process this command Stack trace: at System.Windows.Forms.Form.UpdateLayered() at System.Windows.Forms.Form.OnHandleCreated(EventArgs e) at System.Windows.Forms.Control.WmCreate(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ScrollableControl.WndProc(Message& m) at System.Windows.Forms.ContainerControl.WndProc(Message& m) at System.Windows.Forms.Form.WmCreate(Message& m) at System.Windows.Forms.Form.WndProc(Message& m) at System.Windows.Forms