Automation Error Problem In Loading Vba
Contents |
down your search results by suggesting possible matches as you type. Showing results for Search instead for Do you mean Search the Community Advanced
Vba Automation Error The Interface Is Unknown
Search Forums | Ideas Browse by product Products 3ds vba automation error the object has disconnected from its client Max A360 Products Advance Steel Alias APIs and Programming ArtCAM AutoCAD AutoCAD 360
Vba Automation Error The Object Invoked Has Disconnected From Its Clients
AutoCAD Architecture AutoCAD Civil 3D AutoCAD Electrical AutoCAD for Mac AutoCAD Land Desktop AutoCAD LT AutoCAD Map 3D AutoCAD Mechanical AutoCAD MEP AutoCAD vba automation error exception occurred P&ID AutoCAD Plant 3D AutoCAD Raster Design AutoCAD Structural Detailing AutoCAD Utility Design Autodesk Media and Entertainment AutoSketch BIM 360 Building Ops Buzzsaw BXD: Synthesis CFD Configurator 360 Constructware Design Review DWG TrueView Exchange Apps Fabrication FeatureCAM Flow Design ForceEffect FormIt 360 Fusion 360 Fusion Connect vba automation error catastrophic failure Fusion Lifecycle Fusion Team Game Making Helius Composite Helius PFA Infrastructure Map Server InfraWorks 360 Insight 360 Inventor Inventor HSM & HSMWorks CAM Maya Mechanical Desktop Mockup 360 Moldflow Nastran Nastran In-CAD Navisworks Point Layout PowerInspect PowerMill PowerShape ReCap 360 ReMake Remote Revit Robot Structural Analysis Screencast & Project PRAXIS SimStudio Simulation Mechanical Smoke Structural Bridge Design Vault VRED New Users Getting Started with your Autodesk Product Suites Factory Design Utilities Product Design Suite International Forums Deutsch Español Français Português Русский Türkiye 日本語 中文 Other Forums Community Topics Autodesk Labs Archived Forums Close Visual Basic Customization Autodesk Community > AutoCAD > AutoCAD Customization > Visual Basic Customization > Initializing VBA System...; error: Automation Error. Problem in loading DVB AutoCAD: AutoCAD Customization: Visual Basic Customization: Initializing VBA System...; error: Automation Error. Problem in loading DVB: Pag
AutoCAD. Home Videos Sales Products Trial Purchase Manufacturers Academic Support Tech Support Installation Documentation Community Trainer Knowledge Base>Planting Issues>Presentation> Automation Error: Problem in Loading
Vba Automation Error Unspecified Error
Application Issue You tried to use one of the vba automation error system call failed Land F/X toolsand received the following error message: Automation error: Problem in loading application. For
Vba Automation Error Library Not Registered
example, you may have received this message while trying to use ourColor Rendertool. In this case, some of your plant categories may not be receiving http://forums.autodesk.com/t5/visual-basic-customization/initializing-vba-system-error-automation-error-problem-in/td-p/2442346 color symbols. For example, your trees may be receiving color symbols, but your shrubs, Shrub Areas, and groundcovers are not. Cause This issue can result from a corrupt CAD installation. However, simply restarting CAD can sometimes solve the problem. Solution 1 Restart CAD, then run the Land https://www.landfx.com/kb/planting-issues/presentation/item/2682-automation-error.html F/Xtool again. In some cases, this step alone can resolve the issue. 2 If restarting CAD didn't help, try rebooting your computer, opening CAD, and trying the toolagain. 3 If rebooting didn't do the trick, it's time to repair your CAD installation. 4 Once you've completed the repair steps, reboot your computer ad open CAD. You should now be able to use the Land F/X toolsuccessfully. Last modified on Monday, 28 September 2015 14:10 Contact Land F/X 3165 Broad St. #114 San Luis Obispo, CA 93401 +1 (805) 541-1003 GBR: +44 07507 418948 UAE: +971 52 974 4594 AUS: +61 0481 245 094 Our professional landscape and irrigation design plugin for AutoCAD makes specification and calculation simple, giving you the time to design. Cloud Details Planting Irrigation SketchUp F/X CAD Newsletter ArchiveRegistration Form ContactGalleries & Examples News JavaScript is currently disabled.Please enable it for a better experience of Jumi.
here for a quick overview of the site Help Center Detailed answers to any questions you might have Meta Discuss the workings and policies http://stackoverflow.com/questions/34803843/excel-vba-automation-error-due-to-jan-2016-office-update-probably-caused-by-m of this site About Us Learn more about Stack Overflow the company Business Learn more about hiring developers or posting ads with us Stack Overflow Questions Jobs Documentation Tags Users Badges http://adndevblog.typepad.com/autocad/2012/06/error-problem-in-loading-application-on-64-bit-os-when-using-getinterfaceobject.html Ask Question x Dismiss Join the Stack Overflow Community Stack Overflow is a community of 4.7 million programmers, just like you, helping each other. Join them; it only takes a minute: automation error Sign up Excel VBA “Automation Error” due to Jan 2016 Office Update, probably caused by MSCOMCTL.OCX (Microsoft Windows Common Controls 6.o (Service Pack 6)) up vote 8 down vote favorite 2 EDITED ONCE SOLUTION WAS FOUND: I have added a Treeview Active X Control to one of our spreadsheet, using Microsoft Windows Common Controls 6.0 (Service Pack 6), i.e. MSCOMCTL.OCX which lives in vba automation error c:\Windows\SysWOW64\ KB2881029 (Security Update for Microsoft Office 2010 32-Bit Edition) (MS16-004), pushed out from Microsoft on the 15/01/2016 (or thereabout), installs a new MSCOMCTL.OCX (version 6.1.98.46 which was "Created" 9/12/2015, but "Accessed" (i.e. installed on the computer) at the time of the update). This made the workbook "loose" reference to MSCOMCTL.OCX (quote marks on "loose", because the reference is still ticked but no longer works, the workbook doesn't compile because of "Compile error: Object library feature not supported" or "Automation error") It seems that the update modifies the registry key HKEY_CLASSES_ROOT\TypeLib{831FDD16-0C5C-11D2-A9FC-000F8754DA1}\ by adding a SubKey 2.0, but leaves it empty, and doesn't register the new MSCOMCTL.OCX. Fixing the problem requires 3 steps: 1) MSCOMCTL.OCX. needs to be un-registered and re-registered (Start button/search/command/right click command prompt/run as admistirator: c:\Windows\system32>Regsvr32 /u C:\Windows\SysWOW64\MSCOMCTL.OCX c:\Windows\system32>Regsvr32 C:\Windows\SysWOW64\MSCOMCTL.OCX When registering the new MSCOMCTL.OCX (Version 6.1.98.46) via REGSVR32, a new key is added in the Registry: HKEY_CLASSES_ROOT\TypeLib{831FDD16-0C5C-11D2-A9FC-000F8754DA1}\2.2 If there was a SubKey named 2.1 already existing, it enters a reference that 2.2 is now the Key for use. But it doesn't do anything to the empty 2.0 SubKey ! If there
"Problem in loading application" on 64 bit OS when using GetInterfaceObject By Adam Nagy I have an AutoCAD .NET AddIn which provides an ActiveX server that allows me to drive my AddIn from an external application. This works fine on a 32 bit OS, but on 64 bit I get a "Problem in loading application" error when using GetInterfaceObject() to access my ActiveX server. I checked and the AddIn is loaded, so I'm not sure what goes wrong. Solution When you are building your application on a 64 bit OS, then the ActiveX server inside your AddIn is registered by Visual Studio in the 32 bit hive of the registry since Visual Studio itself is 32 bit even on a 64 bit OS. So you have to register your component yourself using the 64 bit version of regasm. The easiest solution is if you just add a Build Event to your project which runs after each successful build of your project: "C:\Windows\Microsoft.NET\Framework64\v2.0.50727\regasm.exe" "$(TargetPath)" /tlb /codebase Posted at 06:48 AM in .NET, Adam Nagy, AutoCAD | Permalink Reblog (0) Comments Error "Problem in loading application" on 64 bit OS when using GetInterfaceObject By Adam Nagy I have an AutoCAD .NET AddIn which provides an ActiveX server that allows me to drive my AddIn from an external application. This works fine on a 32 bit OS, but on 64 bit I get a "Problem in loading application" error when using GetInterfaceObject() to access my ActiveX server. I checked and the AddIn is loaded, so I'm not sure what goes wrong. Solution When you are building your application on a 64 bit OS, then the ActiveX server inside your AddIn is registered by Visual Studio in the 32 bit hive of the registry since Visual Studio itself is 32 bit even on a 64 bit OS. So you have to register your component yourself using the 64 bit version of regasm. The easiest solution is if you just add a Build Event to your project which runs after each successful build of your project: "C:\Windows\Microsoft.NET\Framework64\v2.0.50727\regasm.exe" "$(TargetPath)" /tlb /codebase View the entire comment thread. Please enable JavaScript if you would like to comment on this blog. Search Submit AutoCAD DevBlogge