Powercenter Database Driver Error
Contents |
WizardInformatica Cloud for Amazon AWSComplex Event ProcessingProactive Healthcare Decision ManagementProactive MonitoringReal-Time Alert ManagerRule PointData IntegrationB2B Data ExchangeB2B Data TransformationData Integration HubData ReplicationData ServicesData Validation OptionFast CloneInformatica PlatformMetadata database driver error in informatica cmn_1022 ManagerPowerCenterPowerCenter ExpressPowerExchangePowerExchange AdaptersData QualityAddress DoctorAddress Doctor CloudData as a cmn_1022 database driver error sql server ServiceData ExplorerData QualityData Quality Services (Strike Iron)Data Security Group (Formerly ILM)Data ArchiveData Centric SecuritySecure@SourceSecure TestingMaster cmn_1022 database driver error informatica sql server Data ManagementIdentity ResolutionMDM Big Data Relationship ManagementMDM Multidomain EditionMDM Registry EditionProcess AutomationActiveVOSCloud ExtendProduct Information ManagementInformatica ProcurementProduct Information ManagementUltra MessagingUltra Messaging OptionsUltra Messaging Persistence
Cmn_1022 Database Driver Error... Informatica To Teradata
EditionUltra Messaging Queuing EditionUltra Messaging Streaming EditionVibe Data StreamDocumentationKnowledge BaseResourcesPAM (Product Availability Matrices)Support TVInformatica Expert AssistantVelocity (Best Practices)Mapping TemplatesDebugging ToolsUser Groupsglobal.search.communityLog inSign Up Informatica Network > Complex Event Processing > Proactive Monitoring > PowerCenter Operations > Discussions Please enter a title. You cannot post a blank message. cmn_1022 database driver informatica Please enter your message and try again. 4 Replies Latest reply: Apr 25, 2014 1:04 AM by Subhrangshu Mondal CMN_1022[Database driver error...] :--Error while connecting to source Subhrangshu Mondal Apr 24, 2014 6:24 AM Hi,I'm facing a problem in connectivity as below : -- 1.When i'm importing table metadata in source analyzer(Designer),using Datasource name & server_name(service name as specified in tns file),i'm able to do so. 2.when i'm connecting to the source database using Toad,SQLPLUS in cmd using the service name,i'm able to do so. 3.But i'm not able to ping to the source server from my local env. 4.But,the main problem is when i'm creating a relational connection in workflow manager(relational connection browser) giving giving connect string : --- Source_IP:port/service_name & assigning it as source connection in connection value,it's throwig error : --Severity Timestamp Node Thread Message Code Me
here for a quick overview of the site Help Center Detailed answers to any questions you might have Meta Discuss the workings and policies of this site cmn_1022 database driver event...error occurred loading library About Us Learn more about Stack Overflow the company Business Learn more about
Database Driver Error... Function Name Execute
hiring developers or posting ads with us Stack Overflow Questions Jobs Documentation Tags Users Badges Ask Question x Dismiss Join
Cmn_1022 Database Driver Error Oracle
the Stack Overflow Community Stack Overflow is a community of 6.2 million programmers, just like you, helping each other. Join them; it only takes a minute: Sign up Database driver error when loading https://network.informatica.com/thread/18011 data with Informatica into Oracle XE 10 g up vote 1 down vote favorite I'm trying to load within an Oracle XE 10g database. When I run an Informatica PowerCenter Workflow, I get a following error: CMN_1022 Database driver error... CMN_1022 [Database driver event...Error occurred loading library [pmora8.dll]. System error encountered is 193. Error text is %1 is not a valid Win32 application. .] Any http://stackoverflow.com/questions/15637513/database-driver-error-when-loading-data-with-informatica-into-oracle-xe-10-g ideas what might be causing this error? My environment is as follows: Windows Server 2008 R2 Informatica PowerCenter 9.5 Oracle XE 10 G Powercenter repository is on SQL Server 2012. oracle driver informatica-powercenter informatica share|improve this question asked Mar 26 '13 at 12:50 JEdward 23114 Are your PATH and LIBRARY_PATH environment variables set up correctly? Is the library pmora8.dll where it should be? –ophintor Mar 26 '13 at 13:08 I have e.g Oracle in my PATH variable: C:\oraclexe\app\oracle\product\10.2.0\server\bin;. But I cannot find LIBRARY_PATH variable, what should be its value? Where pmora8.dll should reside? –JEdward Mar 26 '13 at 13:15 Set it to %ORACLE_HOME%/lib. Not sure about pmora8.dll, but I suppose somewhere in the Informatica directory (I've never used Informatica) –ophintor Mar 26 '13 at 13:19 I did that but it did not help. I have several pmora8.dll in my Informatica folders, I think it is fine. –JEdward Mar 26 '13 at 13:35 " %1 is not a valid Win32 application" maybe it's somehow pointing at the 64 bit DLL incorrectly. –Nick.McDermaid Nov 13 '15 at 2:50 add a comment| 2 Answers 2 active oldest vot
new comments by email My Email You can cancel email alerts at anytime. Comments (7) boppana81 http://www.indeed.com/forum/job/informatica-developer/Database-error-while-running-workflow/t59279 in Arlington Heights, Illinois 101 months ago Hi Iam running a http://dwbitechguru.blogspot.com/2014/07/troubleshooting-common-informatica.html seesion.Iam unable to run Workflow.When i run Debug it shows me the data loaded into target. It shows me the following Error message in Session log WRITER_1_*_1> WRT_8229 Database errors occurred: ORA-26002: Table TGT.T_SG_21 has index defined upon it. Database driver error... Function Name : Prepare database driver DPL SQL Stmt : INSERT INTO t_SG_21(Primarykey,EMPLOYEE_ID,FIRST_NAME,LAST_NAME ,EMAIL,PHONE_NUMBER,HIRE_DATE,JOB_ID,SALARY,COMMIS SI ON_PCT,DEPARTMENT_ID) VALUES ( ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?) Oracle Fatal Error Database driver error... Function Name : Execute Multiple SQL Stmt : INSERT INTO t_SG_21(Primarykey,EMPLOYEE_ID,FIRST_NAME,LAST_NAME ,EMAIL,PHONE_NUMBER,HIRE_DATE,JOB_ID,SALARY,COMMIS SI ON_PCT,DEPARTMENT_ID) VALUES ( ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?) Oracle database driver error Fatal Error WRITER_1_*_1> Fri Jun 13 15:39:44 2008 WRITER_1_*_1> WRT_8076 Writer run terminated. [Commit Error] WRITER_1_*_1> WRT_8333 Rolling back all the targets due to fatal session error. WRITER_1_*_1> WRT_8325 Final rollback executed for the target [t_SG_22, t_SG_21] at end of load WRITER_1_*_1> Fri Jun 13 15:39:44 2008 WRITER_1_*_1> WRT_8081 Writer run terminated. [Error in loading data to target table [t_SG_21]] WRITER_1_*_1> WRT_8168 End loading table [t_SG_22] at: Fri Jun 13 15:39:44 2008 WRITER_1_*_1> WRT_8168 End loading table [t_SG_21] at: Fri Jun 13 15:39:44 2008 WRITER_1_*_1> WRT_8035 Load complete time: Fri Jun 13 15:39:44 2008 - Was this comment helpful? Yes (2) / No Reply - Report abuse hemantabishi in Bombay, India 101 months ago I think,it's kind of constraint violation.Primary key will be violating duplicates to enter. So it fires the error. correct me if i am wrong. - Was this comment helpful? Yes (4) / No (3) Reply - Report abuse wish in Honolulu, Hawaii 98 months ago Try to load it normal rather than Bulk. U
Informatica Error Messages and the resolution Tweet Pin It Common Informatica Error Messages and the resolution: 1) ERROR 7/21/2014 5:16:25 PM READER_1_1_1 HIER_28056 XML Reader: Error [ExpectedCommentOrPI] occurred while parsing:[FATAL: Error at (file /data/pmrootfolder/test.xml, line 1, char 28236 ): Expected comment or processing instruction.]; line number [1]; column number [28236] Database Error: Failed to connect to database using user [TESTDB] and connection string [TOREST].]. ERROR 7/16/2014 10:40:18 AM READER_1_1_1 BLKR_16001 Error connecting to database... RESOLUTION: Check connectivity to database. If not able to connect to database, please contact the dba to resolve the issue with database. For XML writer issues check also: http://dwbitechguru.blogspot.ca/2014/11/xml-customizations-in-informatica_88.html 2) Error message for the failure : ERROR : (8806 | TRANSF_1_1_1) : (IS | ETL_IS) : : pmsql_50065 : [ERROR] ODL error: FnName: Execute -- Communication link failure. RESOLUTION: Check connectivity to integration server or database. Error connecting to database [ [IBM][CLI Driver] SQL30081N A communication error has been detected. Communication protocol being used: "TCP/IP". Communication API being used: "SOCKETS". Location where the error was detected: "172.168.10.1". Communication function detecting the error: "connect". Protocol specific error code(s): "146", "*", "*". SQLSTATE=08001 RESOLUTION: Check connectivity to database. 3) FATAL 9/9/2013 9:31:28 AM *********** FATAL ERROR : An unexpected condition occurred in file [/pmroot/pc9x_root/910HF/build/powrmart/server/cmnutils/soutstream.cpp] line [214]. Aborting the DTM process. Contact Informatica Global Customer Support. *********** RESOLUTION: This is bug with informatica 9 version. Please recover the session and it should work properly. 4) ERROR 9/13/2013 6:20:08 AM DIRECTOR REP_12400 Repository Error ( ORA-30032: the suspended (resumable) statement has timed out ORA-01536: space quota exceeded for tablespace 'TEST_DATA' RESOLUTION: Problem with oracle tablespace.Fix the table space issue. 5) ERROR 4/5/2013 4:21:40 AM WR