replies Latest Post - 2013-04-30T17:05:48Z by matthewpmattson Display:ConversationsBy Date 1-3 of 3 Previous Next matthewpmattson 2700067GGT 2 Posts Pinned topic Tracing aix disk operation error SC_DISK_ERR4 2013-04-29T20:42:45Z | Tags: Answered question This question has been answered.
Aix Fcp_err4
Unanswered question This question has not been answered yet. Hi all, I have some AIX hosts sc disk err4 aix connected via SAN to a 3PAR storage array and while running I/O on the disks I am seeing some TEMP errors in my errpt. See below
Sc_disk_err7
for full details: from the errpt -c command DCB47997 0429144313 T H hdisk1 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk11 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk11 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk20 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk4 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk15 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk15 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk5 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk2 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk2 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk13 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk13 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk17 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk17 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk16 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk5 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk5 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk2 DISK OPERATION ERROR DCB47997 0429144613 T H hdisk1 DISK OPERATION ERROR detail of the error: --------------------------------------------------------------------------- LABEL: SC_DISK_ERR4 IDENTIFIER: DCB47997 Date/Time: Sun Apr 28 22:14:51 CDT 2013 Sequence Number: 33081 Machine Id: 00F7A89E4C00 Node Id: blue7 Class: H Type: TEMP WPAR: Global Resource Name: hdisk18 Resource Class: disk Resource Type: 3PAR_VV_MPIO Location: U8231.E1C.06A89ER-V1-C35-T1-W20210002AC0185E0-L12000000000000 VPD: Manufacturer................3PARdata Machine Type and Model......VV S
CenterInternet of Things News and EventsConnectDeveloper NetworkPartner CommunitiesGlobal Accounts and GSI CustomersMember DirectoryMy CommunityMy GroupsSpaces I FollowContentBookmarksLog in0SearchSearchSearchCancelError: You don't have JavaScript enabled. This tool uses JavaScript and much of it will not work correctly without it enabled. Please turn JavaScript back on and reload this page. Please enter a title. You can not post a blank message. Please type your message and try again. More discussions in Solution and Product Forums Where is this place located?HDS https://www.ibm.com/developerworks/community/forums/html/topic?id=43abe789-d952-4458-bb99-cdf562ebc5a3 CommunityAll PlacesSolution and Product Forums 1 Reply Latest reply on Jun 7, 2013 8:33 PM by Legacy HDS Forums Temp disk errors in AIX cause oracle to hang and dlm commands to hang Legacy HDS Forums Jun 7, 2009 6:23 AM Originally posted by: PP BIJU KRISHNANI have been having sleepless nights https://community.hds.com/thread/2065 for the past few months due to the following issuesCommon System specsAIX 5.3 TL06 and TL08HDLM 5.81.2.1USP-VSAN - Brocade 4100/4900/48K - FOS 6.1.0c--------------------------------------------------------------------------------------------------------------The foll type of AIX errors cause oracle to hangDCB47997 0605201809 T H hdisk42 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk31 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk38 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk37 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk13 DISK OPERATION ERROR DCB47997 0604070809 T H hdisk125 DISK OPERATION ERROR LABEL: SC_DISK_ERR4IDENTIFIER: DCB47997Date/Time: Thu Jun 4 07:08:17 CUT 2009Sequence Number: 1095955Machine Id: 00CE6CDE4C00Node Id: pat2047Class: HType: TEMPResource Name: hdisk250Resource Class: diskResource Type: HitachiLocation: U7311.D20.6555C3B-P1-C03-T1-W50060E800545321A-L4A000000000000VPD: Manufacturer................HITACHI Machine Type and Model......OPEN-V Part Number................. ROS Level and ID............36303033 Serial Number...............50 04532 EC Level.................... FRU Number.................. Device Specific.(Z0)........00000332CF000002 Device Specific.(Z1)........3D14 2L .... Device Specific.(Z2).........0== Device Specific.(Z3)......... Device Specific.(Z4).........Z.. Device Specific.(Z5)........ Device Specific.(Z6)........DescriptionDISK OPERATION ERRORProbable CausesMEDIADASD DEVICEUser CausesMEDIA DEFECTIVE Recommended Actions FOR REMOVABLE MEDIA, CHANGE MEDIA AND RETRY PERFORM PROBLEM DETERMINATION PROCEDURESFailur
SERVICES Services Overview Education Services Business Critical Services Consulting Services Managed Services Appliance Services CUSTOMER CENTER Customer Center Support https://www.veritas.com/support/en_US/article.000008439 Community MyVeritas Customer Success Licensing Programs Licensing Process ABOUT About Corporate Profile Corporate Leadership Newsroom Research Exchange Investor Relations Careers Legal Contact Us English http://www.aixusergroup.com/cgi-bin/aixuser/YaBB.pl?num=1401966555/0 中文(简体) English Français Deutsch Italiano 日本語 한국어 Português Español USA Site: Veritas Veritas PartnerNet DCB47997 disk operation error in errpt Article:000008439 Publish: Article disk operation URL:http://www.veritas.com/docs/000008439 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a Veritas Account now! Welcome First Last Your Profile Logout Sign in to Subscribe Please sign in to set up your subscription. Close Sign In Print Article Products Article disk operation error Languages Subscribe to this Article Manage your Subscriptions Problem Multiple "DISK OPERATION ERROR" message during restart of system. Error Message DCB47997 0506172404 T H hdisk13 DISK OPERATION ERRORDCB47997 0506172404 T H hdisk13 DISK OPERATION ERRORDCB47997 0506172404 T H hdisk17 DISK OPERATION ERROR Cause When the system is restarted after installation of the product and configure I/O fencing, following error messages may be noted in errpt. This can be safely ignored...DCB47997 0506172404 T H hdisk13 DISK OPERATION ERRORDCB47997 0506172404 T H hdisk13 DISK OPERATION ERRORDCB47997 0506172404 T H hdisk17 DISK OPERATION ERROR...# /etc/vxfen -startup# /sbin/init.d/vxfen start# service vxfen start# /etc/init.d/vxfen start This will also be seen during every restart of the system and starting I/O fencing. Solution These messages can be safely ignored.Applies ToAIX 5.3; SFRAC 5.0mp1, 2 nodes Terms of use for this information are found in Legal Notices.
Related Articles ADCB47997 DISK OPERATION ERROR (Read 1 times) SAn846 Freshman AIX User Group Rocks! Posts: 1 DCB47997 DISK OPERATION ERROR Jun 5th, 2014, 6:09am Hello all,i am facing some issue in one of p740 server and AIX7.1 System Model: IBM,8233-E8BMachine Serial Number: 0603F8VProcessor Type: PowerPC_POWER7Processor Implementation Mode: POWER 7Processor Version: PV_7_CompatNumber Of Processors: 12Processor Clock Speed: 3724 MHzCPU Type: 64-bitKernel Type: 64-bitLPAR Info: 1 06-03F8VMemory Size: 31744 MBGood Memory Size: 31744 MBPlatform Firmware level: AL730_122Firmware Version: IBM,AL730_122Console Login: enableAuto Restart: trueFull Core: falseNX Crypto Acceleration: Not Capablei am getting error DCB47997 0605050014 T H hdisk16 DISK OPERATION ERROR4B436A3D 0605050014 T H fscsi3 LINK ERRORDCB47997 0605050014 T H hdisk16 DISK OPERATION ERROR4B436A3D 0605050014 T H fscsi3 LINK ERRORDCB47997 0605050014 T H hdisk16 DISK OPERATION ERROR4B436A3D 0605050014 T H fscsi3 LINK ERRORDCB47997 0605050014 T H hdisk6 DISK OPERATION ERRORDCB47997 0605050014 T H hdisk8 DISK OPERATION ERROR4B436A3D 0605050014 T H fscsi3 LINK ERROR4B436A3D 0605050014 T H fscsi1 LINK ERRORDCB47997 0605050014 T H hdisk8 DISK OPERATION ERROR4B436A3D 0605050014 T H fscsi3 LINK ERROR[/b][/b] Back to top IP Logged Pages: 1 AIX User Group Forum › General Discusion › General Board ‹ Previous topic | Next topic › Sponsored by Datatrend Technologies AIX & IBM are registered trademarks of International Business Machines. AIX User Group Forum » Powered by YaBB 2.2! YaBB © 2000-2007. All Rights Reserved.