Dvw-500 Error Codes
Contents |
slack of the tape is detected during threading or unthreading, and then tape
Sony Dvw A500
protection is done. Detected when the ratio of the FG frequency at a supply reel, take-up reel and threading motor
Dvw A500p
is less than the specified value. 02 REEL TROUBLE-2 The slack or breaking of the tape is detected in search, fast forward, or rewind mode, and then tape protection is done. Detected when
Dvw-a500 Maintenance Manual
the ratio of the FG frequency at a supply reel and take-up reel is less than the specified value. 03 REEL TROUBLE-3 The slack or breaking of the tape is detected in playback mode, or either of the lock of the supply or take-up reel is detected, and then tape protection is done. Detected when the FG frequency at a supply or take-up reel is zero (0), or sony dvw-a500 manual when the tension detected from a tension sensor is less than 15g 04 REEL TROUBLE-4 It is detected that the tape does not run at the speed of designation in fast forward or rewind mode, and then tape protection is done. Depends on the comparison between the tape speed using the FG frequency at supply and take-up reels and the designated speed. 05 REEL TROUBLE-5 It is detected that the supply or take-up reel cannot stop with a cassette is not inserted, or detected that over current has been flowing to supply and take-up reels. Detected using the FG frequency or current at supply and/or take-up reels. 06 TAPE TENSION ERROR When excessive tension is detected, tape protection is done. Detected when the tension detected from a tension sensor is more than 55g. 07 CAPSTAN TROUBLE It is detected that the tape does not run at the speed of designation in play or search modem and tape protection is done. Detected at the tape speed detected from the FG frequency at a capstan motor. 08 DRUM TROUBLE It is detected that drum motor rotation I not normal, and then tape protection is done. Detected when the drum speed obtained fr
Return to posts index • Read entire thread Error 03 on DVW-A500by Ken Swanson on Jan 3, 2008 at 11:06:27 pm Hi, folks. I came across this forum earlier today, and it appears to be quite active dvw-500 and helpful. So here's my question... My organization has a Sony DVW-A500 Digital Betacam. Up sony dvw 500 until just before the holidays it was working just fine. But now when I put in a tape and push play, it dvw 500p displays the Error 03 on the front panel. I have the Maintenance Manual (1st Ed., Rev. 6) which indicates a "Reel Trouble 3" problem and suggests that cause is a slack tape or the supply or take-up http://www.matrixav.com/reference/dvw_error_codes.htm lock is detected. At this point, the only way to take the tape out that (I can see) seems to be turning off the unit, taking off the top panel, then alternately rotating the threading motor block and shifting the ME lever, thence followed by turning the yellow pulley to manually eject the tape. If I don't try pushing the play button--just put the tape in and then eject--it seems to behave itself. In https://forums.creativecow.net/readpost/21/856901 all cases, it appears to be threading the tape around the drum okay. I just went through the different Servo/DT checks, as outlined in the maintenance manual. Everything passed, and the unit seem to function normally as specified in the test procedures. I'm still somewhat in a learning mode, although I've had other hardware/software experience. And we have a lot of pretty skilled tech-types who do a lot of work on different kinds of instruments. I'm pretty certain that if we could somehow pinpoint where the trouble was coming from or why it was happening, we could fix it; however, at the moment all I've got is symptoms and no cause. Have others seen this? Is it just in need of a good cleaning, or is there something else going on? (It's happened with several tapes, by the way.) Is there some indicator--such as a board light--or sensor that I can check, or some test to try, or some measurement to take that would help identify the issue? Thanks in advance for any advice. -Ken Swanson Posts IndexRead ThreadReport Post Current Message Thread: Error 03 on DVW-A500 by Ken Swanson on Jan 3, 2008 at 11:06:27 pmRe: Error 03 on DVW-A500 by Bob Zelin on Jan 4, 2008 at 6:36:11 pm LOGIN TO REPLY © 2016 CreativeCOW.net All Rights Reserved[TOP]