Home > error e obj 102 016 > error e-obj-102-016 language command from

Error E-obj-102-016 Language Command From

EVENTS wth " Not enough space" error message. Subscribe You can track all active APARs for this component. APAR status Closed as unreproducible. Error description During testing in the JPMC certification environment, the event count was increased to 60,000 events in both the Primary and Aggregate Object Servers. The Primary Object Server was stopped. When clients failed over to the Backup Object Server, the Backup Object Server core dumped during a resync from a Collection to Aggregation Object Server gateway. Object Server log shows the following errors: 11/21/09 13:11:43: Error: E-OBJ-102-019: Failed to execute parsed language command. (12:Not enough space) 11/21/09 13:11:43: Error: E-OBJ-102-017: Language command from Impact@dss0s383 failed. Not enough space on line 1 of statement 'select * from alerts.status where StateChange >= 1258153124 AND Class != 10500 AND (Class = 40090 or Class = 40091) and Severity >=0 and ProcessReq=322 and Region = 4 and ShareFlag=2 order by StateChange ;' 11/21/09 13:11:44: Error: E-OBJ-102-016: Language command from GateWay@dss0s377 failed. Not enough space on line 344 of statement 'UPDATE alerts.status VIA ['TEC-COLUMBUS-CERT111258675041'] SET AckRequired=0,AckTime=1258675047,Acknowledged=0,Agent='/usr/loca l/Tivoli /tec_columbus.conf',AlertDetails='',AlertFlag=0,AlertGroup='ITM_ ManagedS ystem',AlertKey='111258675041',AlertTeam='',A...' at or near ''Job:@FTPRQSB2 on BMPT: CPF9999 received' The Backup Object Server was automatically restarted by Process Control, and core dumped again with similar errors. On the third restart of the Backup Object Server, the resync completed without issue and the Backup Object Server continued to run without any problems. No remedial action was taken to reduce event counts - the issue resolved itself after the third restart. "Not enough space" errors like the error above typically have been seen when the Object Server exceeds the hard limit. However, the Object Server database size on disk was much smaller than the 500 MB limit. And, that does not explain why the resync was successful on the third try or why the Primary Object Server continued to run without problems. The customer's Object Server log from one crash has been uploaded to the PMR in /ecurep/pmr/8/4/84493,082,000/mail20091

Manager Auth Source Change Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] The SAF files contain events that may have come in during the shutdown, or during the transition that weren't fully processed. If there are any changes to the structure of the database from 3.6 to 7.1 they may attempt to insert invalid data into the Object Server database as the SAF is processed by it's associated part, and http://www.ibm.com/support/docview.wss?uid=swg1IZ68985 generate errors. Errors cause the SAF file to be skipped until the next restart, and the process repeats. Bill Beasley Airversent, Inc. Owings Mills, MD bbeasley at airversent.com -----Original Message----- From: users-bounces at netcoolusers.org [mailto:users-bounces at netcoolusers.org] On Behalf Of Bharathi, Mohan Sent: Friday, September 21, 2007 8:44 AM To: users at netcoolusers.org https://netcoolusers.org/archives/users/2007-September/039119.html Subject: Re: [INUG-Users] E-OBJ-102-016: Language command from .... Thanks all for your suggestions. Surprisingly the same 3.6 probes were working fine in our other environment( that is OMNI 7.1) .But we bumped in to this on other environment. Along with the probes, we even faced the same error with ISM monitors.. Restarted helped for few though...But why shld we delete these SAF and def files...? Thanks, Bharathi -----Original Message----- From: users-bounces at netcoolusers.org [mailto:users-bounces at netcoolusers.org] On Behalf Of Wiemers, Ulrich Sent: Friday, September 21, 2007 6:54 AM To: users at netcoolusers.org Subject: Re: [INUG-Users] E-OBJ-102-016: Language command from .... sometimes it was in addition necessary to delete some files in $OMNIHOME/var like store&foreward (don't have the exact name) or like the NCOMS.def. my 2ct. Ulli ________________________________ Von: users-bounces at netcoolusers.org im Auftrag von Michael Troitzsch Gesendet: Do 20.09.2007 22:54 An: users at netcoolusers.org Betreff: Re: [INUG-Users] E-OBJ-102-016: Language command from .... Barathi, looks like you have c

IONIX Splunk IBM Tivoli Forums Polls About Us Our Services Search form Search Share this page User login Username * http://www.guardianms.com/content/fixed-language-command-gatewayncoms-failed-nomodify-constraint-violation-line-1 Password * Create new account Request new password Log in Related https://docs.djangoproject.com/en/1.10/ref/checks/ Posts How to enable SSL\HTTPS and disable HTTP on ITM 6.2.2 TEPS Bulk Filter Creation on Netcool WebGUI Creating large maps in Netcool WebGUI the fast way... Clickable map links to open Active Event List filters in another portlet. Splunk Rules for Netcool Tutorials IBM error e-obj-102-016 Tivoli FIXED: Language command from gateway@NCOMS failed. NOMODIFY constraint violation on line 1 FIXED: Language command from gateway@NCOMS failed. NOMODIFY constraint violation on line 1 Recently upgraded to OMNIbus 7.3.1 FixPack 7 and decided to test our failover capability.  When the Gateway on the backup server was retarted, the following errors appeared in the NCOMSB.log: 2013-09-16T10:52:48: error e-obj-102-016 language Error: E-OBX-102-018: Failed to resolve parsed language command. (-901:NOMODIFY constraint violation) 2013-09-16T10:52:48: Error: E-OBX-102-016: Language command from gateway@NCOMSB failed. NOMODIFY constraint violation on line 1 of statement 'UPDATE transfer.security_restrictions VIA [0,4,'Sync_Events'] SET RestrictionName='Sync_Events',DatabaseName='alerts',TableName='status';' at or near 'RestrictionName' I edited the NCOMS_GATE.map to show "ON INSERT ONLY" for @RestrictionName as this is a NOMODIFY field.  Fields that are set to NOMODIFY cannot be updated through the gateway.  The following shows the changes made to NCOMS_GATE.map: online bad credit loans     CREATE MAPPING SecurityRestrictionFiltersMap      (             'GranteeType'           =       '@GranteeType'  ON INSERT ONLY,             'GranteeID'             =       '@GranteeID'    ON INSERT ONLY,             'RestrictionName'       =       '@RestrictionName' ON INSERT ONLY,    #Added ON INSERT ONLY             'DatabaseName'          =       '@DatabaseName',             'TableName'             =       '@TableName'      );   Category:IBM TivoliShare: —GuardianMS Guarding your IT Experience! Tags:NOMODIFYGatewayFailoverOMNIbus Fixpacks Add new comment Your name Subject Comment * Switch to plain text editor More information about text formatsFiltered HTMLPlain text Home page By submitting this form, you accept the Mollom privacy

framework¶ The system check framework is a set of static checks for validating Django projects. It detects common problems and provides hints for how to fix them. The framework is extensible so you can easily add your own checks. For details on how to add your own checks and integrate them with Django's system checks, see the System check topic guide. API Reference¶ CheckMessage¶ class CheckMessage(level, msg, hint=None, obj=None, id=None)[source]¶ The warnings and errors raised by system checks must be instances of CheckMessage. An instance encapsulates a single reportable error or warning. It also provides context and hints applicable to the message, and a unique identifier that is used for filtering purposes. Constructor arguments are: level The severity of the message. Use one of the predefined values: DEBUG, INFO, WARNING, ERROR, CRITICAL. If the level is greater or equal to ERROR, then Django will prevent management commands from executing. Messages with level lower than ERROR (i.e. warnings) are reported to the console, but can be silenced. msg A short (less than 80 characters) string describing the problem. The string should not contain newlines. hint A single-line string providing a hint for fixing the problem. If no hint can be provided, or the hint is self-evident from the error message, the hint can be omitted, or a value of None can be used. obj Optional. An object providing context for the message (for example, the model where the problem was discovered). The object should be a model, field, or manager or any other object that def

 

Related content

No related pages.