Home > foreign configuration > new media error found on controller

New Media Error Found On Controller

Contents

MM0001: Shared tape library is not detected by Windows Server 2003 MediaAgents MM0002: Barcodes change foreign configuration found on adapter after firmware upgrade or restart MM0003: Block size errors occur during

Foreign Configuration Found On Adapter Press Any Key To Continue Or C

backup job or auxiliary copy operations MM0004: "End-of-Data Marker" and "No More Data is on there are offline or missing virtual drives with preserved cache the Tape" errors MM0005: There is no media in the drive MM0006: Tape block size is not recognized while media label is read MM0007: There is

Dell Raid Foreign Configuration Found

no active controller for the library MM0008: Performing a read test with TapeToolGui utility MM0009: I/O errors occur with HP drives MM0010: Error Code 32:406 All device streams configured to this Storage Policy including their multiplexing factor are in use MM0018: Mount error occurs on Fujitsu ETERNUS CS High End Device import foreign configuration dell perc after media migration MM0020: Command line does not return to the prompt during an export operation Export Media Process Timed Out with "No response from Media Manager service. Server=[Server_Name]" Error MM0022: Barcode labels are no longer valid MM0021: Error Code 25:31 Tape Volume Block Size Encountered is Different from This Product's Standard MM0023: Error Code 32:23 Failed to Mount Media MM0037: Error Code 62:90: Failure During Delete Operation on CommServe Database MM0050: No Library Controller is Active MM0052: Library is Marked Offline After Turning Off then On MM0053: Library Reading Barcodes Differently MM0001: Tape library is not detected by Windows Server 2003 MediaAgents Symptom When certain Windows updates and service packs are installed on Windows Server 2003 MediaAgents, tape libraries might not be detected. Resolution Apply the Windows hot fix as described in the following Microsoft Knowledge Base article: "Error returned by the IOCTL_SCSI_GET_INQUIRY_DATA operation on a Windows Server 2003-based computer: 'STATUS_INVALID_DEVICE_REQUEST'", http:

Svenska Türkçe 简体中文 How to Troubleshoot Hard Drives and RAID Controller Errors on Dell PowerEdge 12G This article provides information on how to troubleshoot hard drive and RAID Controller

Multi Bit Ecc Errors Were Detected On The Raid Controller Dell

errors on Dell PowerEdge™ 12G Servers. Show all | Hide

There Are Offline Or Missing Virtual Drives With Preserved Cache Ibm

all Issue 1: Post Error Messages Message Meaning There are X enclosures connected to connector Y, but media elements definition only maximum of 4 enclosures can be connected to a single SAS connector. Please remove the extra enclosures then restart your system. When the BIOS detects more https://documentation.commvault.com/commvault/v10/article?p=features/tape_library/troubleshooting.htm than 4 enclosures connected to a single SAS connector, it displays this message. You must remove all additional enclosures and restart your system. Cache data was lost, but the controller has recovered. This could be due to the fact that your controller had protected cache after an unexpected power loss and your system was without http://www.dell.com/support/article/us/en/04/SLN129432/en power longer than the battery backup time. Press any key to continue or 'C' to load the configuration utility. This message displays under the following conditions: The adapter detects that the cache in the controller cache has not yet been written to the disk subsystem. The controller detects an Error- Correcting Code (ECC) error while performing its cache checking routine during initialization. The controller discards the cache rather than sending it to the disk subsystem because the data integrity cannot be guaranteed. To resolve this problem, allow the battery to charge fully. If the problem persists, the battery or adapter DIMM might be faulty. The following virtual disks have missing disks: (x). If you proceed (or load the configuration utility), these virtual disks will be marked OFFLINE and will be inaccessible. Please check your cables and ensure all disks are present. Press any key to continue, or 'C' to load the configuration utility. The message indicates that some configured disks were removed