Home > kta pump > kta pump synchronization error

Kta Pump Synchronization Error

Contents

may have changed. The fast protein liquid chromatography (FPLC) instrument is from Pharmacia. It is comprised of pumps, switching valves, sample loop, separation column, UV detector, conductivity meter, sample

Akta Fplc Troubleshooting

collector, and plotter. The instrument is run from an internal computer. Contents 1 akta purifier troubleshooting Parts 2 General Use 2.1 Standard settings: 2.2 Chart recorder: 2.3 To wash pumps: 2.4 To wash the column:

Akta Error Codes

2.5 Trouble with columns: 2.6 Loading a sample: 2.7 Running a method: 2.8 Trouble with a program: 2.9 Fraction Collector: 2.10 When you are finished running the FPLC: 3 Types of Columns akta prime plus user manual (that we have): 3.1 Superdex 200 Size Exclusion 3.2 Superdex 75 Size Exclusion 3.3 Anion exchange, HiTrap Q Parts The pumps: The pumps can run a constant percentage of two combined buffers or a gradient between the two buffers over time. The internal computer: The instrument runs off an internal computer and can be run in manual mode or method mode. The valves: The pump p-900 user manual pumps are connected to valves which send the buffers in the desired direction: either directly to the waste, directly onto the column or directly through the sample loop and then onto the column. The sample loops: The sample loops come in a variety of sizes based on your sample size. Use the sample loop closest to the volume of your sample. We have 25 ul, 50 ul, 100 ul, 200 ul, 500 uL and 8mL sample loops. The column: The column is connected to the switching valve. Many different columns are sold for purification by different methods (ion exchange, hydrophobicity, size exclusion). We have a gel filtration column (Superose 12), a cation exchange column (Mono S) and an anion exchange (HiTrap Q). We also have some small testing columns in the drawer with the FPLC. Columns should be stored in 24% ethanol/H2O when not in use. The UV detector: The UV detector is run from a small unit above the main FPLC computer and can detect 254 nm or 280 nm. It is usually set to detect 280 nm. The conductivity meter: The conductivity meter is the small black tube

We refurbish and test every component separately to

Akta Purifier Error Codes

deliver an up-to-standard system to our customers. Our akta prime plus error 65 range of services for AKTA products include system repairs, calibrations, upgrades, preventive maintenance,

Akta Pump Error 121

service contracts, and component level repairs. AKTA Explorer repair services include but are not limited to: UV-900 lamp replacement and alignment, http://openwetware.org/wiki/Wittrup:_FPLC_general_use drying cartridge(desiccant) replacement UV-900 "lamp module failure" and "calibration failed" errors P-900 pump synchronization, motor and belt replacement P-900 seal replacement, upgrades from 10ml to 100ml and vice versa Component level repair on all AKTA modules PV-908, INV-907, IV-908, M-925, P-960, P-950, http://www.sci-support.com/items/GE-Amersham-Pharmacia-Akta-Explorer-10-FPLC-1592.htm Air-900 repairs Frac-950 alignment, "sensor error" repair AKTA Explorer 10 Specifications: • Flow rate up to 10 ml/min, pressureup to 25MPa • Complete set of motor valves. • P-900 pump, UV-900 detector, pH/C-900 pH/conductivity detector, FRAC-900 fraction collector • Wavelength 190 to 700 nm • Conductivity up to 1000 mS/cm • Optional AIR, sample pump, autosampler, and FRAC-950. Browse Category: AKTA FPLC Copyright © 2016 Scientific Support, Inc. All rights reserved All Registered Trademarks are the property of their respective owners. Home Product List Warranty Contacts Scientific Support,Inc 23449 Foley Street Hayward, CA 94545 Phone 510.783.1127 Fax 510.783.1168 info@sci-support.com Refurbished Lab and Analytical Equipment Toll Free 877 831-5580 Phone 510 783-1127 Fax 510 783-1168 info@sci-support.com Equipment Service and Repair

be down. Please try the request again. Your cache administrator is webmaster. Generated Thu, 20 Oct 2016 05:09:52 GMT by s_wx1011 (squid/3.5.20)

 

Related content

No related pages.