Things Small and Medium Business Service Providers All Solutions Services Advise, Transform and Manage Financing and Flexible Capacity IT Support Services Education and Training Services All Services Products Integrated Systems Composable Systems Converged Systems Hyper Converged Systems Blade Systems Infrastructure Management Software Application Lifecycle Management Application Delivery Management Big Data Analytics DevOps Enterprise Security Hybrid and Private Cloud Information Governance Information Management IT Service Management Operations Management Server Management Software as a Service (SaaS) Software-Defined Data Center Storage Management All Software Servers Rack Servers Tower Servers Blade Servers Density Optimized Mission Critical Servers Servers for Cloud Server Management All Servers Storage All-flash and Hybrid Storage Midrange and Enterprise Storage Entry Storage Systems Data Availability, Protection and Retention Software Defined Storage Management and Orchestration Storage Networking All Storage Networking Switches Routers Access Points and Controllers Wireless LAN Campus and Branch Networking Data Center Networking Wide Area Network Software Defined Networking Network Functions Virtualization Network Management All Networking About UsSupportClearType to search2086159Solutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small and Medium Business Service Providers All Solutions Services Advise, Transform and Manage Financing and Flexible Capacity IT Support Services Education and Training Services All Services Products Integrated Systems Composable Systems Converged Systems Hyper Converged Systems Blade Systems Infrastructure Management Software Application Lifecycle Management Application Delivery Management Big Data Analytics DevOps Enterprise Security Hybrid and Private Cloud Information Governance Information Management IT Service Management Operations Management Server Management Software as a Service (SaaS) Software-Defined Data Center Storage Management All Software Servers Rack Servers Tower Servers Blade Servers Density Optimized Mission Criti
Server Build Tight Budget: SBS + Hyper-V + Vyatta (SDN) + Asterisk (VoIP) + Terminal Server Home Test Lab Setup a home lab for testing and learning purposes. New STEM School Building Outfitting a brand new school building with state of the art educational technology with an emphasis on STEM curriculum. TECHNOLOGY IN THIS DISCUSSION Join the Community! Creating your account only takes a few minutes. Join Now Hello - Today, I noticed there was an amber light on disk 6 of my 8 disk chassis for an HP DL380 https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/POST-Error-1792-Drive-Array-Reports-Valid-Data-Found-in-Array/td-p/4651365 G5 server. All the other lights are green solid or green blinking except for disk 6. This server has VMware ESXi 3.5 installed with two datastores both in separate RAID configurations. Disk 6 is a part of the second datastore and I know that the VMware VI Client cannot see the individual disks I opened the iLO2 through the web console and found the status IML message https://community.spiceworks.com/topic/105176-post-error-1792-drive-array-reports-valid-data-found-in-array-accelerator "POST Error: 1792-Drive Array Reports Valid Data Found in Array Accelerator" Posted on 3/24/2010. The host server has been restarted multiple times since then and it was shutdown gracefully. I have no idea if this is related to the amber light on the disk. Anyone know what could cause this? Or how to resolve it? Reply Subscribe View Best Answer RELATED TOPICS: Large drive array HP DL380 G5 Drive / Array Issue array accelerator status is "not configured"   19 Replies Pure Capsaicin OP Scott Alan Miller Jul 20, 2010 at 3:42 UTC Niagara Technology Group (NTG) is an IT service provider. That light means that your drive has failed. You need to get a replacement and swap it out right away. 0 Serrano OP Justin2100 Jul 20, 2010 at 3:53 UTC I having bad luck with drives lately. So that is the most likely case? What would happen if I restarted the host server? Could it be an outdated array controller driver? 0 Pure Capsaicin OP Scott Alan Miller Jul 20, 2010 at 4:08 UTC Niagara Technology Group (NTG) is an IT service provider. Do not restart that b
for Help Receive Real-Time Help Create a Freelance Project Hire for a Full Time Job Ways to Get Help Ask a Question Ask for Help Receive Real-Time Help Create a Freelance Project Hire for a Full Time Job Ways to Get Help Expand Search Submit Close https://www.experts-exchange.com/questions/26700542/POST-Error-1792-Drive-Array-Reports-Valid-Data-Found-in-Array-Accelerator.html Search Login Join Today Products BackProducts Gigs Live Careers Vendor Services Groups Website Testing Store Headlines Experts Exchange > Questions > POST Error: 1792-Drive Array Reports Valid Data Found in Array Accelerator Want to Advertise Here? Solved http://blu3yytech.blogspot.com/2010/11/hp-proliant-post-error-1792-drive-array.html POST Error: 1792-Drive Array Reports Valid Data Found in Array Accelerator Posted on 2010-12-24 Server Hardware 1 Verified Solution 3 Comments 4,886 Views Last Modified: 2012-05-10 Please advice me how to rectify the below error in HP ProLiant post error ML370 G2 POST Error: 1792-Drive Array Reports Valid Data Found in Array Accelerator 0 Question by:badamramesh Facebook Twitter LinkedIn Google LVL 3 Best Solution bySUSQ It could quite possibly be due to an unexpected shutdown. Also, if it is consistantly occuring even during a clean reboot; you should check the firmware and driver of the array controller and apply updates Go to Solution 3 Comments LVL 5 Overall: Level 5 Message Expert Comment by:terrygreensill2010-12-24 post error 1792-drive this usually appears after an unexpected shutdown, has the server had a power outage? This message means that data is the in memory of your raid card waiting to be writen to disk. 0 LVL 3 Overall: Level 3 Message Accepted Solution by:SUSQ2010-12-24 It could quite possibly be due to an unexpected shutdown. Also, if it is consistantly occuring even during a clean reboot; you should check the firmware and driver of the array controller and apply updates as needed. 0 Message Author Closing Comment by:badamramesh2010-12-29 I have updated array controller firmware and issue resolved 0 Write Comment First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone. Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. Featured Post Find Ransomware Secrets With All-Source Analysis Promoted by Recorded Future Ransomware has become a major concern for organizations; its prevalence has grown due to past successes achieved by threat actors. While each ransomware variant is different, we’ve seen some common tactics and trends used among the authors of the malware. CONTINUE READING Suggested Solutions Title # Comments Views Activity Server 2008 (TS) Freezing with Printer Redirection 3 29 126d Dell enterprise HDDs in an HP server. 5 46 75d exchange, storage, vmware 19 81 60d Del
Reports Valid Data Found in Array Accelerator... ...Data will automatically be written to drive array.Possible Cause: Power was interrupted while data was in the array accelerator memory. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.Action: No action is required. No data has been lost. Perform orderly system shutdowns to avoid leaving data in the array accelerator.1792 Error Message Error Message: 1792-Drive Array Reports Valid Data Found in Array Accelerator......Data will automatically be written to drive array.Audible Beeps: NonePossible Cause: Audible Beeps: None Possible Cause:Power was interrupted while data was in the array accelerator memory. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.Action: No action is required. No data has been lost. Perform orderly system shutdowns to avoid leaving data in the array accelerator. Posted by Blu3yy at 10:11 Reactions: Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest No comments: Post a Comment Newer Post Older Post Home Subscribe to: Post Comments (Atom) Blog Archive ► 2014 (16) ► June (1) ► May (3) ► April (7) ► March (5) ► 2013 (34) ► December (6) ► October (2) ► September (2) ► August (2) ► July (6) ► June (1) ► May (3) ► April (6) ► March (4) ► February (2) ► 2012 (10) ► November (1) ► April (1) ► March (6) ► February (2) ► 2011 (43) ► November (6) ► October (5) ► August (1) ► July (8) ► June (4) ► May (3) ► April (3) ► March (12) ► January (1) ▼ 2010 (114) ▼ November (9) Trusted Connection Setup - SQL Server 2008 Sophos Enterprise Console - Updating License Detai... Ubuntu Netbook Remix 10.10 & Calibre Ebook Manage... Printer Migrator Terminal 2008 Server - Install mode Microsoft Dynamics GP - Add-on Software Blackberry Torch - Enterprise Activation HP Proliant - Post Error: 1792 Drive Array Reports... HP Proliant Server Troubleshooting Guide ► October (29) ► September (22) ► August (8) ► July (1) ► June (8) ► May (4) ► April (7) ► March (7) ► February (7) ► January (12) ► 2009 (129) ► December (8) ► November (7) ► October (4) ► September (14) ► August (6) ► July (37) ► June (46) ► May (1) ► March (1) ► February (5) Awesome Inc. template. Powered by Blogger.