Files ... Cancel cannot login to the datasource Dear All When users are trying to login in PW Explorer ,They are getting error "Cannot login to the Datasource" Last Error 32768. Pw Integration server and Explorer version - 08.09.04.50 Database - SQl 2005 on windows 2003 server Any Suggestion Plz projectwise error checking out a file of document Thank you Sultan Sultan Sadique Sun, Aug 9 2009 12:59 PM Cancel 6 Replies (Most projectwise error copying document to client Recent Reply) Michael McCarty Sun, Aug 9 2009 5:39 PM I think you will need to contact Bentley Technical Support for assistance with this projectwise login error 32768 issue. Cancel John James Mon, Aug 10 2009 7:06 PM Are you using Windows network authentication? If so,make sure the user's accounts may nave expired or their passwords may need to be reset. Cancel Jeff Burrill Tue, Aug 11 2009 projectwise error 55511 8:51 AM When all users are getting Error 32768 at login, that almost always indicates a problem with the datasource'sdatabase connection. If you cannot evenlog into PW with the logical Administrator account, thenthe database connection isthe likely the problem.Make sure you can connect to it using the user name/pass defined in the database for the datasource thatusers can't connect to, either through ODBC or using SQL Studio. Also, if the server's name and/or IP have recently changed (or of the database
Projectwise Cannot Login To The Datasource
server it on a different box) this can also lead to connectivity problems between the database and PW. Barring that, if you are using PW Authentication server foruser authentication,check if the PW Auth. server service is configured to Log On as aspecific user account on the server (such a local or domain specific service acct) rather than Local System, and make sure that that the serviceacct isn't locked out and allowed to log on as a service.Update thePW Auth service Log Onaccount passwordif it has recently changed,then re-start the PW Auth service. Also, make sure that PW user acct name/pass is up-to-date (right click Properties on Windows Synchronization area in PW Admin -can't recall the specific verbiage but I'll update this later if you need specifics). This info seems to get hosed up sometimes, so just retype the values and apply them. This particular fix usually only fixes domain synchronization issues, but it doesn't hurt to do this either and in some cases has resolved the 32768 issue for us when nothing else did. If none of these things address your issue, you really should contect Bentley support directly. Please note that I post here on a voluntary basis and am not a Bentley employee. Cancel Audrius Zimnickas Tue, Aug 11 2009 10:15 AM In reply to Jeff Burrill: I have to respond to this last comment. While remarks about database connection are valid, let's be clear about the ser
Files ... Cancel Answered Error 32768, Cannot login remotely. Hi all, For demo
Projectwise Error 55501
purpose, I recently setup a projectWise server, everything works fine, except the remote logging in. All users cannot login to the server either through Explorer or Admin client, however, if I install the two software and login locally on the server itself, it work http://communities.bentley.com/products/projectwise/content_management/f/342986/t/34740 perfectly. The network configuration on client is as follow: Name: Demo Hostname: 192.168.10.53 Port: 5800 Could this be due to wrong configuration of the Integration server? Best regards, Minh Nguyen Explorer v8i SS4 login Minh Nguyen Wed, Jan 8 2014 11:44 PM Cancel http://communities.bentley.com/products/projectwise/content_management/f/342986/t/93747 All Responses Answers Only Darius.Perminas Fri, Jan 10 2014 1:02 AM In reply to Marty.Nickel: PW Network Configuration applet must be configured with hostnames and 'Prevent UDP' checkbox hard-checked if you want to specifically point to concrete PW Integration Server. --- Minh Nguyen has registered a Service Request for this earlier yesterday and case above has been confirmed as working solution. Answer Verified By: Darius.Perminas Cancel
^ Go to first post Communities Home Getting Started Community Central Products Support Secure File Upload Feedback Support and Services Home Product Support Downloads User Management Licensing Manager Training and Learning Home About Bentley Institute My Learning History Reference Books Social Media LinkedIn Facebook Twitter YouTube RSS Feed Email © 2016 Bentley Systems, Incorporated| Contact Us| Privacy| Terms of Use| CookiesFiles ... Cancel +Content Management - Wiki +Bentley i-model Composition Server +Bentley i-model Composition Server V8i Bentley LEARN Conference - London, June 6 - 7 http://communities.bentley.com/products/projectwise/content_management/w/wiki/16997.error-58063-invalid-username-and-password-combination +Bentley Transmittal Connector for ProjectWise +Bentley Transmittal Portal +Bentley Transmittal Services http://communities.bentley.com/products/projectwise/content_management/w/wiki/9350.error-58510-your-projectwise-user-profile-requires-that-you-activate-this-projectwise-product-using-the-select-server-settings-configured-on-this-workstation +ProjectWise Caching Server +ProjectWise Change Storage Area +ProjectWise Deliverables Management +ProjectWise Design Integration Server +ProjectWise Document Publisher -ProjectWise Explorer Client 55037 Error moving document User cannot delete corrupt files A way to list users and working dirs A way to search documents in a specific projectwise error version and showing related references (references and referenced by) on search results A way to search only document versions in PW Application Error The instruction at 0x5ad71531 referenced memory at 0x00000014 Attribute Exchange tabs grayed out in Excel 2007 Attribute not showing in modify command dialog box +Audit Trail - ProjectWise Explorer Client +BS1192 Rules Engine projectwise login error - ProjectWise Explorer Client Cannot open file class not registered +Check In Dialog - ProjectWise Explorer Client Copy files with document codes Datasources not displaying in ProjectWise Explorer +Document Code - ProjectWise Explorer Client +Document Creation - ProjectWise Explorer Client +Documentation & Help - ProjectWise Explorer Client Error -11149 Cannot save instance to storage Error 50176 Cannot start application for the specified document. Check your program associations. Operating system function call failed. Error on thread and file stuck with coming in status +Export / Import Tool - ProjectWise Explorer Client Failed to get object identifier by its GUID +Folders / Subfolders - ProjectWise Explorer Client +GUI - ProjectWise Explorer Client +Installation - ProjectWise Explorer Client +Integration - AutoCAD - ProjectWise Explorer Client +Integration - DGN Platform - ProjectWise Explorer Client +Integration - MicroStation - ProjectWise Explorer Client +Integration - Office - ProjectWise Explorer Client +Integration - Revit - ProjectWise Explorer Client Invalid socket The connection to the remote host is broken Issue with Bentley Connect Edition a
Files ... Cancel +Content Management - Wiki +Bentley i-model Composition Server +Bentley i-model Composition Server V8i Bentley LEARN Conference - London, June 6 - 7 +Bentley Transmittal Connector for ProjectWise +Bentley Transmittal Portal +Bentley Transmittal Services +ProjectWise Caching Server +ProjectWise Change Storage Area +ProjectWise Deliverables Management +ProjectWise Design Integration Server +ProjectWise Document Publisher -ProjectWise Explorer Client 55037 Error moving document User cannot delete corrupt files A way to list users and working dirs A way to search documents in a specific version and showing related references (references and referenced by) on search results A way to search only document versions in PW Application Error The instruction at 0x5ad71531 referenced memory at 0x00000014 Attribute Exchange tabs grayed out in Excel 2007 Attribute not showing in modify command dialog box +Audit Trail - ProjectWise Explorer Client +BS1192 Rules Engine - ProjectWise Explorer Client Cannot open file class not registered +Check In Dialog - ProjectWise Explorer Client Copy files with document codes Datasources not displaying in ProjectWise Explorer +Document Code - ProjectWise Explorer Client +Document Creation - ProjectWise Explorer Client +Documentation & Help - ProjectWise Explorer Client Error -11149 Cannot save instance to storage Error 50176 Cannot start application for the specified document. Check your program associations. Operating system function call failed. Error on thread and file stuck with coming in status +Export / Import Tool - ProjectWise Explorer Client Failed to get object identifier by its GUID +Folders / Subfolders - ProjectWise Explorer Client +GUI - ProjectWise Explorer Client -Installation - ProjectWise Explorer Client Connecting to multiple gateway servers, not all datasources appear Document status incorrect on one PW client machine Error 114 while setting up User Synchronization Service Error 1722 uninstalling Integration server Error 41 when deleting folder Error 58510. Your ProjectWise user profile requires that you activate this ProjectWise product using the SELECT Server settings configured on this workstation. Error Could not connect to the datasource Fatal Error during Explorer installation