Catch Raise Application Error Oracle
Contents |
to your PL/SQL program. With many programming languages, unless you disable error checking, a run-time error such as stack overflow or division by zero stops normal processing and returns control to the operating system. raise application error oracle forms With PL/SQL, a mechanism called exception handling lets you bulletproof your program so that
Raise Application Error Oracle 11g
it can continue operating in the presence of errors. This chapter contains these topics: Overview of PL/SQL Runtime Error Handling Advantages raise application error in oracle example of PL/SQL Exceptions Summary of Predefined PL/SQL Exceptions Defining Your Own PL/SQL Exceptions How PL/SQL Exceptions Are Raised How PL/SQL Exceptions Propagate Reraising a PL/SQL Exception Handling Raised PL/SQL Exceptions Overview of PL/SQL Compile-Time
Raise Application Error In Oracle Syntax
Warnings Overview of PL/SQL Runtime Error Handling In PL/SQL, an error condition is called an exception. Exceptions can be internally defined (by the runtime system) or user defined. Examples of internally defined exceptions include division by zero and out of memory. Some common internal exceptions have predefined names, such as ZERO_DIVIDE and STORAGE_ERROR. The other internal exceptions can be given names. You can define exceptions of your own in the oracle raise exception with message declarative part of any PL/SQL block, subprogram, or package. For example, you might define an exception named insufficient_funds to flag overdrawn bank accounts. Unlike internal exceptions, user-defined exceptions must be given names. When an error occurs, an exception is raised. That is, normal execution stops and control transfers to the exception-handling part of your PL/SQL block or subprogram. Internal exceptions are raised implicitly (automatically) by the run-time system. User-defined exceptions must be raised explicitly by RAISE statements, which can also raise predefined exceptions. To handle raised exceptions, you write separate routines called exception handlers. After an exception handler runs, the current block stops executing and the enclosing block resumes with the next statement. If there is no enclosing block, control returns to the host environment. For information on managing errors when using BULK COLLECT, see "Handling FORALL Exceptions with the %BULK_EXCEPTIONS Attribute". Example 10-1 calculates a price-to-earnings ratio for a company. If the company has zero earnings, the division operation raises the predefined exception ZERO_DIVIDE, the execution of the block is interrupted, and control is transferred to the exception handlers. The optional OTHERS handler catches all exceptions that the block does not name specifically. Example 10-1 Runtime Error Handling DECLARE stock_price NUMBER := 9.73; net_earnings
program to continue to operate in the presence of errors. Topics: Overview of PL/SQL Run-Time Error Handling Guidelines for Avoiding and Handling PL/SQL Errors
Raise_application_error In Oracle
and Exceptions Advantages of PL/SQL Exceptions Predefined PL/SQL Exceptions Defining Your Own
Oracle Predefined Exceptions
PL/SQL Exceptions How PL/SQL Exceptions Are Raised How PL/SQL Exceptions Propagate Reraising a PL/SQL Exception Handling Raised PL/SQL oracle sqlerrm Exceptions Overview of PL/SQL Compile-Time Warnings Overview of PL/SQL Run-Time Error Handling In PL/SQL, an error condition is called an exception. An exception can be either internally defined (by http://docs.oracle.com/cd/B19306_01/appdev.102/b14261/errors.htm the run-time system) or user-defined. Examples of internally defined exceptions are ORA-22056 (value string is divided by zero) and ORA-27102 (out of memory). Some common internal exceptions have predefined names, such as ZERO_DIVIDE and STORAGE_ERROR. The other internal exceptions can be given names. You can define your own exceptions in the declarative part of any PL/SQL block, subprogram, or package. https://docs.oracle.com/cd/B28359_01/appdev.111/b28370/errors.htm For example, you might define an exception named insufficient_funds to flag overdrawn bank accounts. User-defined exceptions must be given names. When an error occurs, an exception is raised. That is, normal execution stops and control transfers to the exception-handling part of your PL/SQL block or subprogram. Internal exceptions are raised implicitly (automatically) by the run-time system. User-defined exceptions must be raised explicitly by RAISE statements or invocations of the procedure DBMS_STANDARD.RAISE_APPLICATION_ERROR. To handle raised exceptions, you write separate routines called exception handlers. After an exception handler runs, the current block stops executing and the enclosing block resumes with the next statement. If there is no enclosing block, control returns to the host environment. For information about managing errors when using BULK COLLECT, see Handling FORALL Exceptions (%BULK_EXCEPTIONS Attribute). Example 11-1 calculates a price-to-earnings ratio for a company. If the company has zero earnings, the division operation raises the predefined exception ZERO_DIVIDE, the execution of the block is interrupted, and control is transferred to the exception handlers. The optional OTHERS handler catches all exceptions that the blo
FunctionsRegular Expressions FunctionsStatistical FunctionsLinear Regression FunctionsPL SQL Data TypesPL SQL StatementsPL SQL OperatorsPL SQL ProgrammingCursorCollectionsFunction Procedure PackagesTriggerSQL PLUS Session EnvironmentSystem Tables Data DictionarySystem PackagesObject OrientedXMLLarge ObjectsTransactionUser http://www.java2s.com/Tutorial/Oracle/0480__PL-SQL-Programming/AcompleteexampleusingRAISEAPPLICATIONERROR.htm PrivilegeA complete example using RAISE_APPLICATION_ERROR : raise_application_error«PL SQL Programming«Oracle PL/SQL TutorialOracle PL/SQL TutorialPL SQL Programmingraise_application_errorSQL> SQL> SQL> create table company( 2 product_id https://www.experts-exchange.com/questions/24112364/catch-RAISE-APPLICATION-ERROR.html number(4) not null, 3 company_id NUMBER(8) not null, 4 company_short_name varchar2(30) not null, 5 company_long_name varchar2(60) 6 ); Table created. SQL> insert raise application into company values(1,1001,'A Inc.','Long Name A Inc.'); 1 row created. SQL> insert into company values(1,1002,'B Inc.','Long Name B Inc.'); 1 row created. SQL> insert into company values(1,1003,'C Inc.','Long Name C Inc.'); 1 row created. SQL> insert into company values(2,1004,'D Inc.','Long Name D Inc.'); raise application error 1 row created. SQL> insert into company values(2,1005,'E Inc.','Long Name E Inc.'); 1 row created. SQL> insert into company values(2,1006,'F Inc.','Long Name F Inc.'); 1 row created. SQL> SQL> SQL> SQL> SQL> CREATE OR REPLACE PROCEDURE org_proc 2 (p_flag_in VARCHAR2, 3 p_product_id NUMBER, 4 p_company_id NUMBER, 5 p_company_short_name VARCHAR2, 6 p_company_long_name VARCHAR2) 7 IS 8 v_error_code NUMBER; 9 BEGIN 10 IF (p_flag_in ='I')THEN 11 BEGIN 12 INSERT INTO company VALUES(p_product_id,p_company_id,p_company_short_name,p_company_long_name); 13 EXCEPTION WHEN OTHERS THEN 14 v_error_code :=SQLCODE; 15 IF v_error_code =-1 THEN 16 RAISE_APPLICATION_ERROR(-20000,'Organization '||TO_CHAR(p_company_id)||' already exists.'); 17 ELSIF v_error_code =-2291 THEN 18 RAISE_APPLICATION_ERROR(-20001,'Invalid Hierarchy Code '||TO_CHAR(p_product_id)||' specified.'); 19 END IF; 20 END; 21 ELSIF (p_flag_in ='C')THEN 22 BEGIN 23 UPDATE company 24 set company_short_name =p_company_short_name, 25 company_long_name =p_company_long_name 26 WHERE product_id =p_product_id 27 AND company_id =p_company_id; 28
Help Receive Real-Time Help Create a Freelance Project Hire for a Full Time Job Ways to Get Help Ask a Question Ask for Help Receive Real-Time Help Create a Freelance Project Hire for a Full Time Job Ways to Get Help Expand Search Submit Close Search Login Join Today Products BackProducts Gigs Live Careers Vendor Services Groups Website Testing Store Headlines Experts Exchange > Questions > catch RAISE_APPLICATION_ERROR Want to Advertise Here? Solved catch RAISE_APPLICATION_ERROR Posted on 2009-02-04 Oracle Database 1 Verified Solution 6 Comments 4,988 Views Last Modified: 2013-12-18 Is there a way in oracle PL/SQL to catch an RAISE_APPLICATION_ERROR ? I am calling a procedure that RAISE_APPLICATION_ERROR when there is a problem, from an other procedure. I need to catch the RAISE_APPLICATION_ERROR in PL/SQL and correcly handle the error. But I do not know how to catch RAISE_APPLICATION_ERROR. 0 Question by:fpkeegan Facebook Twitter LinkedIn Google LVL 73 Active today Best Solution bysdstuber that might look like... EXCEPTION WHEN OTHERS THEN if SQLCODE = -20001 then dbms_output.put_line('raise application error #1)' elsif SQLCODE = -20002 then dbms_output.put_line('raise Go to Solution 6 Comments LVL 23 Overall: Level 23 Oracle Database 22 Message Active today Expert Comment by:David2009-02-04 Lots of examples on EE in previously asked questions, such as http://www.experts-exchange.com/Database/Oracle/Q_22951085.html?sfQueryTermInfo=1+applic+error+rais 0 LVL 73 Overall: Level 73 Oracle Database 70 Message Active today Expert Comment by:sdstuber2009-02-04 yes, you can write an exception handler with the WHEN OTHERS then check the specific SQLCODE raised (the first parameter of RAISE_APPLICATION_ERROR) 0 LVL 73 Overall: Level 73 Oracle Database 70 Message Active today Accepted Solution by:sdstuber2009-02-04 that might look like... EXCEPTION WHEN OTHERS THEN if SQLCODE = -20001 then dbms_output.put_line('raise application error #1)' elsif SQLCODE = -20002 then dbms_output.put_line('raise application error #2)' end if; 0 LVL 16 Overall: Level 16 Oracle Database 15 Message Expert Comment by:Milleniumaire2009-02-04 In my opinion a