02000 Error Code
Contents |
be down. Please try the request again. Your cache administrator is webmaster. Generated Sun, 02 Oct 2016 17:27:10 GMT by s_hv996 (squid/3.5.20)
them. SQLSTATE Codes Code Condition Oracle Error 00000 successful completion ORA-00000 01000 warning 01001 cursor operation conflict 01002 disconnect error 01003 null value eliminated in set function sql server error code 01004 string data - right truncation 01005 insufficient item descriptor areas 01006
Sqlstate Mysql
privilege not revoked 01007 privilege not granted 01008 implicit zero-bit padding 01009 search condition too long for db2 sql error sqlcode=-803 info schema 0100A query expression too long for info schema 02000 no data ORA-01095 ORA-01403 07000 dynamic SQL error 07001 using clause does not match parameter specs 07002 using clause http://answers.microsoft.com/en-us/windows/forum/windows_8-winapps/error-code-002000-using-xbox/96ec9f6b-8ed3-4d79-afbf-33b1a258f6bf does not match target specs 07003 cursor specification cannot be executed 07004 using clause required for dynamic parameters 07005 prepared statement not a cursor specification 07006 restricted datatype attribute violation 07007 using clause required for result fields 07008 invalid descriptor count SQL-02126 07009 invalid descriptor index 08000 connection exception 08001 SQL client unable to establish SQL connection 08002 connection https://docs.oracle.com/cd/E15817_01/appdev.111/b31228/appd.htm name in use 08003 connection does not exist SQL-02121 08004 SQL server rejected SQL connection 08006 connection failure 08007 transaction resolution unknown 0A000 feature not supported ORA-03000 .. 03099 0A001 multiple server transactions 21000 cardinality violation ORA-01427 SQL-02112 22000 data exception 22001 string data - right truncation ORA-01401 ORA-01406 22002 null value - no indicator parameter ORA-01405 SQL-02124 22003 numeric value out of range ORA-01426 ORA-01438 ORA-01455 ORA-01457 22005 error in assignment 22007 invalid date-time format 22008 date-time field overflow ORA-01800 .. 01899 22009 invalid time zone displacement value 22011 substring error 22012 division by zero ORA-01476 22015 interval field overflow 22018 invalid character value for cast 22019 invalid escape character ORA-00911 ORA-01425 22021 character not in repertoire 22022 indicator overflow ORA-01411 22023 invalid parameter value ORA-01025 ORA-01488 ORA-04000 .. 04019 22024 unterminated C string ORA-01479 .. 01480 22025 invalid escape sequence ORA-01424 22026 string data - length mismatch 22027 trim error 23000 integrity constraint violation ORA-00001 ORA-02290 .. 02299 24000 invalid cursor state ORA-01001 .. 01003 ORA-01410 ORA-08006 SQL-02114 SQL-02117 SQL-02118 SQL-02122 25000 invalid transaction state 26000 invalid SQL statement name 27000 triggered data cha
here for a quick overview of the site Help Center Detailed answers to any questions you might have Meta Discuss the workings and policies of this http://stackoverflow.com/questions/27644411/error-code-1329-sql-state-02000-no-data-for-a-function site About Us Learn more about Stack Overflow the company Business Learn more http://forums.apc.com/spaces/5/smart-ups-symmetra-lx-rm/forums/general/11115/srt10kxli-power-sys-error-00100-and-power-sys-error-02000 about hiring developers or posting ads with us Stack Overflow Questions Jobs Documentation Tags Users Badges Ask Question x Dismiss Join the Stack Overflow Community Stack Overflow is a community of 4.7 million programmers, just like you, helping each other. Join them; it only takes a minute: Sign up Error code sql error 1329, SQL state 02000: No data - for a function up vote 1 down vote favorite I am using mysql 5.0.27. I had written the following function. DELIMITER | CREATE FUNCTION getDebit (trip1 INT UNSIGNED) RETURNS DOUBLE BEGIN DECLARE oldName DOUBLE DEFAULT 0; DECLARE done INT DEFAULT 0; SELECT SUM(COALESCE(amt,0)) INTO oldName FROM expenses where head IN(SELECT distinct name FROM head where payType='Debit') AND trip=trip1 db2 sql error GROUP BY trip; DECLARE CONTINUE HANDLER FOR NOT FOUND SET done = 1; RETURN oldName; END DELIMITER ; It gives the error Error code 1064, SQL state 42000: You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'DECLARE CONTINUE HANDLER FOR NOT FOUND SET done = 1;END' at line 11 . Please help me. mysql sql share|improve this question edited Dec 25 '14 at 6:37 xrcwrn 1,321113673 asked Dec 25 '14 at 5:21 user2601972 175 It gives error when the resultset is empty –user2601972 Dec 25 '14 at 5:58 check this out stackoverflow.com/questions/3463283/… –Prdp Dec 25 '14 at 6:00 @NoDisplayName,How to apply that solution for this function. –user2601972 Dec 25 '14 at 6:04 1 Seems worth noting that you're using an unsupported version of MySQL. The oldest active version is 5.5. You might want to upgrade. –Tieson T. Dec 25 '14 at 6:43 @Tieson T,is it works fine if i upgraded to mysql5.5 –user2601972 Dec 25 '14 at 6:49 add a comment| active oldest votes Kno
& PowerChute Software Data Center & Facility 3 Phase UPS StruxureWare for Data Centers Security & Environmental Monitoring Discussions NetBotz Hardware & Software Other Environmental Monitoring Products & Questions Other Products, Topics, & Discussions Getting Started General Questions & Suggestions Universal Transfer Switch Mobile Power Packs Server Room & Data Center Design Best Practices Support Getting Started APC Support Website APC Homepage Learning - White Papers Learning - Application Notes Software/Firmware Downloads How to contact APC outside of this community Schneider Electric Buildings Community (BMS & Pelco) Schneider Electric Homepage Knowledge Base home » spaces » Smart-UPS & Symmetra LX / RM » discussion » General » SRT10KXLI power sys error-00100 and power sys error -02000 Activity stream People Content Info Search Discussions SRT10KXLI power sys error-00100 and power sys error -02000 Discussion in Smart-UPS & Symmetra LX / RM started by Hosein , 7/26/2015 6:22 AM Subscribe to RSS Loginto follow, share, and participate in this space. Not a member?Join now Hosein Novice Hosein 7/26/2015 6:22 AM HELLO i installed an APC SRT10KXLI with 3 SRT192BP2 yesterday. after one day working the ups couldn't online . when it get load on the UPS error with this message : "power sys error-00100 " and " power sys error -02000 " the log screen on the ups says : " output relay weld " and "invertr output low ". how can i solve this problem ? has the ups hardware fault or it's software fault ? if the fault is hardware, should i replace the output relay ? thank you . 7734 Views power output relay error inverter low 00100 02000 sys weld Reply Angela Angela 7/27/2015 2:09 PM (in response to Hosein) Could you provide the full logs from this UPS (from its network management interface)? Either from the web under about->Support or individually event.txt, config.ini, and data.txt to start? This will help with a diagnosis/recommendation and is typically required if you'll be work