Db2 Sql Error 601
Contents |
THE OBJECT TYPE C A RENAME DB S T CREATE ALTER RENAME N P E I IDCAMS DELETE CREATE R C DB SQL R DB One sql error 501 of the following situations has been detected: v A CREATE statement tried
Db2 Sqlerror
to create an object name of type obj-type, but an object of that type with the same name is already com.ibm.db2.jcc.am.sqlsyntaxerrorexception: db2 sql error: sqlcode=-601, sqlstate=42710 defined in the DB2 subsystem. – If obj-type is CONSTRAINT, the name was specified in the FOREIGN KEY clause, CHECK clause, PRIMARY KEY clause, or UNIQUE clause of either a CREATE http://www.ibm.com/support/knowledgecenter/SSEPEK_10.0.0/codes/src/tpc/n601.html or ALTER TABLE statement. All referential integrity, check constraint, primary key, and unique key constraint names defined on a table must be unique. – If obj-type is TABLE or VIEW, and a CREATE ALIAS statement failed, then the alias-name specified in the CREATE ALIAS statement is identical to the table name or view name specified. The TABLE or VIEW might not exist in the http://www.sqlerror.de/db2_sql_error_-601_sqlstate_42710.html DB2 subsystem. – If obj-type is DISTINCT TYPE, and a CREATE DISTINCT TYPE statement failed, then there is already a user-defined type existing with the same name as the distinct type name specified in the CREATE DISTINCT TYPE statement. – If obj-type is FUNCTION or PROCEDURE, and a CREATE FUNCTION or CREATE PROCEDURE statement failed, then there is already a routine existing with the same name as the name specified in the CREATE FUNCTION or CREATE PROCEDURE statement. – If obj-type is PROCEDURE, and a CREATE PROCEDURE statement for an SQL procedure failed, then there may already be an SQL procedure that has the same name as the external name that was implicitly or explicitly specified. – If obj-type is FUNCTION, and a CREATE DISTINCT TYPE statement failed, then there is already a user-defined function function existing with the same name as the distinct type that is specified in the CREATE DISTINCT TYPE statement. – If obj-type is SEQUENCE, and a CREATE SEQUENCE statement failed, then there is already a sequence existing with the same name as the sequence name that was specified in the CREATE SEQUENCE statement. <- BACK
SET SCHEMA InstanceName Executing file: /opt/IBM/WebSphere/CommerceServer70/components/foundation/schema/fep1/db2/wcs.schema.foundation.sql Failed to execute: CREATE TABLE fileprocrel ( uploadfile_id BIGINT NOT http://ramaswamykarrawcshub.blogspot.com/2016/02/db2-sql-error-sqlcode-601-sqlstate42710.html NULL, processfile_id BIGINT NOT NULL, optcounter SMALLINT NOT NULL DEFAULT 0 ) IN USERSPACE1 https://www.mssqltips.com/sqlservertip/3289/error-601-could-not-continue-scan-with-nolock-due-to-sql-server-data-movement/ INDEX IN USERSPACE1 BUILD FAILED /opt/IBM/WebSphere/CommerceServer70/components/common/xml/enableFeature.xml:89: The following error occurred while executing this line: /opt/IBM/WebSphere/CommerceServer70/components/common/xml/enableFeature.xml:165: The following error occurred while executing this line: sql error /opt/IBM/WebSphere/CommerceServer70/components/common/xml/databaseTasks.xml:20: The following error occurred while executing this line: /opt/IBM/WebSphere/CommerceServer70/components/common/xml/databaseTasks.xml:97: The following error occurred while executing this line: /opt/IBM/WebSphere/CommerceServer70/components/common/xml/commonEnablementTasks.xml:43: com.ibm.db2.jcc.am.SqlSyntaxErrorException: DB2 SQL Error: SQLCODE=-601, SQLSTATE=42710, SQLERRMC=InstanceName.FILEPROCREL;TABLE, DRIVER=4.14.113 at org.apache.tools.ant.ProjectHelper.addLocationToBuildException(ProjectHelper.java:539) at org.apache.tools.ant.taskdefs.Ant.execute(Ant.java:384) at org.apache.tools.ant.taskdefs.CallTarget.execute(CallTarget.java:107) at org.apache.tools.ant.UnknownElement.execute(UnknownElement.java:275) Problem : fileprocrel table has data (This is occured when db2 sql error we run Foundation Enable Command Second Time) SQLCODE=-601 means the table already exists in your DB and the script is trying to create it and DB2 did not allow that Solution : 1. Drop the FILEPROCREL table OR 2. Restore the DB backup Before start the Feature Enable Process Then Start the Feature Enable Process. Refference : https://www-01.ibm.com/support/knowledgecenter/SSZLC2_7.0.0/com.ibm.commerce.component-services.doc/tasks/twvenablefoundation.htm Posted by Ramaswamy Karra at 06:25 Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest No comments: Post a Comment Newer Post Older Post Home Subscribe to: Post Comments (Atom) About Me Ramaswamy Karra View my complete profile Blog Archive ▼ 2016 (9) ► July (1) ► June (1) ► March (1) ▼ February (6) ERRORCODE=-4472, SQLSTATE=null WCS Instance Creat... DB2 SQL Error: SQLCODE=-601, SQLSTATE=42710, SQLER... DB2 Normal Backup, Online Backup and Restore Co
Read Comments (4) | Related Tips: More > Database Consistency Checks DBCCs Problem When we are querying SQL Server tables with/without the NOLOCK hint we may get a page corruption error like this: "Could not continue scan with NOLOCK due to data movement". Today we will learn how to deal with this issue. Solution In my particular case the error was raised in the Distribution database and was during the execution of a SELECT operation with a NOLOCK hint and then I verified the same error without NOLOCK as well, this error is because one or more data pages are missing at the current position of the scanning with/without NOLOCK locking hint so we can say we have corruption issue in the database. The root cause of this error is because pages were deleted or moved by page splits caused by DML statements so that SQL Server is not able to continue scan operation. In order to verify that it is a page corruption issue you can run the DBCC CHECKDB command with PHYSICAL_ONLY option. DBCC CHECKDB(MY_DATABASE) WITH PHYSICAL_ONLY As a result, you may see many errors: Msg 8909, Level 16, State 1, Line 1 Table error: Object ID 0, index ID -1, partition ID 0, alloc unit ID 0 (type Unknown), page ID (1:219356) contains an incorrect page ID in its page header. The PageId in the page header = (0:0). Msg 8909, Level 16, State 1, Line 1 Table error: Object ID 0, index ID -1, partition ID 0, alloc unit ID 144115188075921408 (type Unknown), page ID (1:219368) contains an incorrect page ID in its page header. The PageId in the page header = (5385:-1048674823). Msg 8939, Level 16, State 98, Line 1 Table error: Object ID 0, index ID -1, partition ID 0, alloc unit ID 6989691077213028352 (type Unknown), page (29184:1694528512). Test (IS_OFF (BUF_IOERR, pBUF->bstat)) failed. Values are 133129 and -14. Msg 8909, Level 16, State 1, Line 1 From the output above we can validate for example that the allocation unit 144115188075921408 does not exist so this is the reason why “data pages are missing” and “(type Unknown)” appear in each message. Well, at this point we know it is a critical issue and now I will show more messages returned by the DBCC command: Msg 8928, Level 16, State 1, Line 1 Object ID 501576825, index ID 1, partition ID 72057594040549376, alloc unit ID 72057594044940288 (type In-row data): Page (1:1408252) could not be processed. Msg 8928, Level 16, State 1, Line 1 Object ID 501576825, index ID 1, partition ID 72057594040549376, alloc unit ID 72057594044940288 (type In-row data): Page (1:1408253) could not be processed. Msg 8928, L