Home > the task > error 11135 sccm

Error 11135 Sccm

Contents

OSD, R3, sccm, SCCM 2007, SCCM 2007 R2, SCCM 2007 R3, SCCM 2007 SP2, sccm2007 by Kenny Buntinx [MVP] A customers the task sequence manager could not successfully complete execution of the task sequence demanded for local support staff to have a simple feature

The Task Sequence Execution Engine Failed Execution Of A Task Sequence

in ConfigMgr 2007 . This feature would be that when operating system deployment has been launched in the task sequence execution engine failed execution of a task sequence 11141 production , the Local Support staff would receive a simple email to say that their deployment was succeeded or not without touching any ConfigMgr console. Out of the box , this was not feasible . A colleague of mine ( Merlijn Vanwaeyenberghe) at that particular customer found a rather simple but effective solution . The steps to reproduce this solution are mentioned below : 1. Go to the Status filer Rules in the following section : 2. Create two status filter rules as shown below . 3.Configure the Status filter Rules as shown below. Create a Status Filter Rule with the following properties: · To notify when a specific TS has succeeded: Source: ConfigMgr Client Site Code: site code Message ID: 11143 Property: Package ID Property Value: Package ID for the OSD Task Sequence to be monitored · To notify when a specific TS has failed: Source: ConfigMgr Client Site Code: site code Component: Task Sequence Engine Severity: Error Property: Package ID Property Value: Package ID for the OSD Task Sequence to be monitored · Actions for both cases: Create 2 Powershell scripts on your local drive. In my case D:\scripts\TSSucceeded_Email_Notification.PS1 and D:\scripts\TSFailed_Email_Notification.PS1 with the following code snippets that are listed below. **********Code Snippet – FAILED *********** param([string]$strComputerName) $erroractionpreference = "SilentlyContinue" $strSMTP = "Your SMTP server " $strSubject = $strComputerName+": OS Deployment FAILED" $strBody = @" The OSD Task Sequence "The name of your tasksequence" has * FAILED * op $strComputerName http://yourSCCMServer/SMSReporting_XXX/Report.asp?ReportID=143&AdvertID=90020066&ComputerName=$st

SMSTS.LOG Empty location for package: _SMSTSP01000F1ApplyOperatingSystem Installation of image 1 in package P01000F1 failed to complete.. The system cannot find the file specified. (Error: 80070002; Source: Windows)ApplyOperatingSystem The resolution was to change the deployment properties on the Task Sequence from "Access content directly from a distribution Point" to "Download content locally". I Believe that changing the operating system package properties under Data Access to "Copy the content in this package to a package share on distribution Points"would have been the other solution to this problem. Posted by Henrik Antin http://scug.be/sccm/2010/10/01/configmgr-osd-task-sequence-success-or-failure-notification/ at 10:30 AM Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest 2 comments: sebusJanuary 22, 2016 at 6:40 PMVery strange, as I get the very error if I DO have "download locally". Error does not appear if I enable "Access content directly from a distribution Point"And it is not the OS package that fails, but MDT custom settings packageReplyDeleteHenrik AntinJanuary 26, 2016 at 9:06 PMThis http://configurationmanager2012.blogspot.com/2013/02/task-sequence-problem-after-migration.html error occured in a migrated task sequence (MDT steps where not possible to migrate using the built in migration jobs) It's recommended to recreate the task sequences in the new environment using the MDT version and templates from the new environment. And then coypy/recreate your custom steps in the new task sequence. Have you tried that?ReplyDeleteAdd commentLoad more... Newer Post Older Post Home Subscribe to: Post Comments (Atom) Blog Archive ► 2016 (3) ► September (2) ► April (1) ► 2015 (10) ► December (1) ► November (2) ► September (2) ► June (1) ► May (1) ► February (3) ► 2014 (4) ► June (1) ► May (1) ► April (1) ► January (1) ▼ 2013 (13) ► December (1) ► November (2) ► October (2) ► May (1) ► April (2) ► March (1) ▼ February (3) SMS_DISTRIBUTION_MANAGER Error Message ID: 2302 Task Sequence problem after SCCM 2007 to SCCM 2012... How to change SQL collation ► January (1) ► 2012 (17) ► December (2) ► November (1) ► September (1) ► July (1) ► June (1) ► May (3) ► April (2) ► March (3) ► January (3) About Me Hen

for Help Receive Real-Time Help Create a Freelance Project Hire for a Full Time Job Ways to Get Help Ask a Question Ask for Help Receive Real-Time Help Create a Freelance Project Hire for a Full Time Job Ways to Get Help Expand Search Submit https://www.experts-exchange.com/articles/1259/SCCM-OSD-Basic-troubleshooting.html Close Search Login Join Today Products BackProducts Gigs Live Careers Vendor Services Groups Website Testing http://www.networksteve.com/enterprise/topic.php/%22Apply_Operating_System%22_because_folder_ends_with_whitespace/?TopicId=32979&Posts=4 Store Headlines Experts Exchange > Articles > SCCM OSD Basic troubleshooting Article Comments6 About the Author More Resources Print Link Facebook Twitter LinkedIn Google Want to Advertise Here? SCCM OSD Basic troubleshooting Awarded Article by HayesJupe On 2011-04-14 Views: 101,277 115,477 Points SCCM 2007 OSD is a fantastic way to deploy operating systems, however, like most things SCCM issues can the task sometimes be difficult to resolve due to the sheer volume of logs to sift through and the dispersed nature of the blog posts that deal with some of these issues. This article will help SCCM OSD newbies with some of these issues. [b]Integrating SCCM and MDT 2008[/b] For our deployments, we always install MDT 2008 on our SCCM server and select Configure ConfigMgr Integrationfrom the MDT area on the start menu. This gives us: Templated task the task sequence sequences we can import into SCCM Additional TS Variables for use in our task sequences Additional options and flexibility around computer backup, USMT etc. For beginners, the template task sequences are a very quick way to get up and running while being guided through the process, while for more advanced users the additional functionality comes in handy when your task sequences become more complex. [b]Setting yourself up[/b] In order to have any chance at troubleshooting SCCM OSD issues, you need to do the following: 1 Install trace32.exe which is part of the SMS 2003 Toolkit 2 (download from Here) 2 Enable command line support within your boot images: a. Go to the properties of your boot image(s) (right click and choose Properties) b. Go to the Windows PE tab and tick the Enable command support (testing only) option. c. When prompted, click on Yes to update your distribution points. d. From within your boot image (Windows PE) environment, you can now press F8 to open up a command window -- very useful for troubleshooting 3 Be familiar with your OS setup log files (e.g. WindowsXP has setupapi.log, netsetup.log etc.)[b]Log files[/b] The root of all Task Sequence troubleshooting is called smsts.log -- and this log is always the first step to troubleshooting any TS issue -- if you have an issue, look

is present during a Refresh installation from Windows XP to Windows 7. We have experienced that the wipe process of "Apply Operating System" fails if there exists folders thats ends with whitespace. We are aware that folders cant be created with a whitespace (or a period) at the end. We suspect the application "Football Manager 2011" (or something) somehow has managed to create this folder. We have experienced the same issue with files that ends with a period. This is the three lines of error from the computer that had folder ending with whitespace: Severity Type Site code Date / Time System Component Message ID Description Error Milestone CM2 02.03.2011 21:39:33 Task Sequence Manager 11170 The task sequence manager could not successfully complete execution of the task sequence. A failure exit code of 16389 was returned. The operating system reported error 156: The recipient process has refused the signal. Error Milestone CM2 02.03.2011 21:24:20 Task Sequence Engine 11141 The task sequence execution engine failed execution of a task sequence. The operating system reported error 2147942545: The directory is not empty. Error Milestone CM2 02.03.2011 21:24:20 Task Sequence Engine 11135 The task sequence execution engine failed executing the action (Apply Operating System) in the group (Install Operating System) with the error code 2147942545 Action output: \client\osdeployment\applyos\installimage.cpp,676) ApplyImage(), HRESULT=80070091 (e:\nts_sms_fre\sms\client\osdeployment\applyos\installimage.cpp,1416) Apply(), HRESULT=80070091 (e:\nts_sms_fre\sms\client\osdeployment\applyos\installimage.cpp,1456) installer.install(), HRESULT=80070091 (e:\nts_sms_fre\sms\client\osdeployment\applyos\installimage.cpp,1527) Closing image file \\\SMSPKGE$\CM2000A5\win7sp1x64.wim Entering ReleaseSource() for \\\SMSPKGE$\CM2000A5reference count 1 for the source \\\SMSPKGE$\CM2000A5\ before releasing Released the resolved source \\\SMSPKGE$\CM2000A5InstallImage( g_InstallPackageID, g_ImageIndex, targetVolume, ImageType_OS, g_ConfigPackageID, g_ConfigFileName, bOEMMedia ), HRESULT=80070091 (e:\nts_sms_fre\sms\client\osdeployment\applyos\applyos.cpp,373) Installation of image 2 in package CM2000A5 failed to complete.. The directory is not empty. (Error: 80070091; So

 

Related content

new task error

New Task Error table id toc tbody tr td div id toctitle Contents div ul li a href The Task Definition Uses A Deprecated Feature Windows a li li a href The Task Definition Uses A Deprecated Feature Send Email a li ul td tr tbody table p Support' started by the task definition uses a deprecated feature email Lasareath Aug Lasareath New Member Hello I just task scheduler send an email deprecated upgraded from to I started re-creating my tasks and I found an error windows task scheduler display a message I added to my task list a task