Adamm Mover Error Getdriveinfo
Contents |
SERVICES Services Overview Education Services Business Critical Services Consulting Services Managed Services Appliance Services CUSTOMER CENTER Customer Center Support Community MyVeritas Customer Success Licensing Programs Licensing Process ABOUT About Corporate Profile Corporate Leadership Newsroom Research Exchange
Adamm Mover Error Getdriveinfo Failure
Investor Relations Careers Legal Contact Us English 中文(简体) English Français Deutsch Italiano adamm mover error read failure 日本語 한국어 Português Español USA Site: Veritas Veritas PartnerNet Deduplication with CASO / MMS backup reports Adamm Mover Error:
Adamm Mover Error Deviceio
GetDriveInfo Failure = ERROR_INVALID_HANDLE Drive Article:000011534 Publish: Article URL:http://www.veritas.com/docs/000011534 Support / Article Sign In Remember me Forgot Password? Don't have a Veritas Account? Create a Veritas Account now! Welcome First Last 33152 adamm mover error Your Profile Logout Sign in to Subscribe Please sign in to set up your subscription. Close Sign In Print Article Products Article Languages Subscribe to this Article Manage your Subscriptions Problem The Deduplication device is either not seen or will not run process jobs, due to Adamm Mover Error Error Message Adamm Mover Error: GetDriveInfo Failure = ERROR_INVALID_HANDLE Drive Cause This error has backup exec 33152 adamm mover error been seen when there is a power interruption to the storage array that hosts the deduplication folder. Solution Often a storage array might be wholly dedicated to deduplication and as such if this were to happen it might not be readily known. A reboot of the server attached to the array corrected the issue.Applies ToBackup Exec 2010 R2 on Windows 2008 with CASO / MMS (Central Administration Server Option / Managed Media Server) configuration and the Deduplication option Terms of use for this information are found in Legal Notices.
Related Articles Article Languages x Translated Content Please note that this document is a translation from English, and may have been machine-translated. It is possible that updates have been made to the original version after this document was translated and published. Veritas does not guarantee the accuracy regarding the completeness of the translation. You may also refer to the English Version of this knowledge base article for up-to-date information. Attachment Products Subscribe to Article Search Survey Did this article answer your question or resolve your issue? No Yes Did this article save you the trouble of coSERVICES Services Overview Education Services Business Critical Services Consulting Services Managed Services Appliance Services CUSTOMER CENTER Customer Center Support Community MyVeritas Customer Success Licensing Programs Licensing Process ABOUT About Corporate Profile Corporate Leadership Newsroom Research Exchange Investor Relations Careers Legal Contact Us English 中文(简体) English Français Deutsch Italiano 日本語 한국어 Português Español USA Site: Veritas Veritas PartnerNet PVLSVR.exe service crashes on Central Admin Server(CASO) in Backup Exec 2012 Article:000018761 Publish: Article URL:http://www.veritas.com/docs/000018761 Support / Article Sign In Remember me Forgot Password? Don't have a https://www.veritas.com/support/en_US/article.000011534 Veritas Account? Create a Veritas Account now! Welcome First Last Your Profile Logout Sign in to Subscribe Please sign in to set up your subscription. Close Sign In Print Article Products Related Articles Article Languages Subscribe to this Article Manage your Subscriptions Problem I may be seen that the PVLSVR.exe service crashes on the https://www.veritas.com/support/en_US/article.000018761 Central Admin Server(CASO) during service startup in Backup Exec 2012 with SP2 installed. Error Message Errors seen in the event logs: Application Event Logs:======================================================Type : ErrorTime : 11:36:06 AMEvent : 58053Source : Backup ExecDescription:Backup Exec Alert: Storage Error(Server: "ServerName") The drive hardware is offline.Please confirm that the drive hardware is powered on and properly cabled. Type : ErrorDate : 9/17/2013Time : 11:36:03 AMEvent : 33152Source : Backup ExecCategory : (1)User : N/AComputer : Domain.ServerName.comDescription:Adamm Mover Error: GetDriveInfo Failure!Error = ERROR_INVALID_HANDLEDrive = "Tape drive 0001"{A8E56AC1-B8F6-4BAC-B5D0-150AAD535C23}Media = ""{00000000-0000-0000-0000-000000000000}Read Mode: SingleBlock(0), ScsiPass(0)Write Mode: SingleBlock(0), ScsiPass(0) Type : ErrorDate : 9/17/2013Time : 11:36:03 AMEvent : 33152Source : Backup ExecCategory : (1)User : N/AComputer : Domain.ServerName.comDescription:Adamm Mover Error: GetDriveInfo Failure!Error = ERROR_INVALID_HANDLEDrive = "Tape drive 0001"{A8E56AC1-B8F6-4BAC-B5D0-150AAD535C23}Media = ""{00000000-0000-0000-0000-000000000000}Read Mode: SingleBlock(0), ScsiPass(0)Write Mode: SingleBlock(0), ScsiPass(0) Type : InformationDate : 9/17/2013Time : 11:33:52 AMEvent : 1001Source : Windows Error ReportingCategory : NoneUser : N/AComputer : Domain.ServerName.comDescription:Fault bucket , type 0Event Name: APPCRASHResponse: Not availableCab Id: 0Problem signature:P1: pvlsvr.exeP2: 14.0.1798.1244P3: 51e07ab1P4: MSVCR100.dllP5: 10.0.30319
Question Answer Questions My Profile ShortcutsDiscussion GroupsFeature RequestsHelp and SupportHow-tosIT Service ProvidersMy QuestionsApp CenterRatings and ReviewsRecent ActivityRecent PostsScript CenterSpiceListsSpiceworks BlogVendor PagesWindows Events Event 33152 (Error) Source: Backup Exec How important is this event? (3 https://community.spiceworks.com/windows_event/show/90-backup-exec-33152 votes) 1 2 3 4 5 not important very important Description Adamm Database Error: Error = Server = "" Active Node = "" Instance = "BkupExec" Database = "" Adamm Database Error: Error = Server = "" Active Node = "" Instance = "BkupExec" Database = "" Add link Text to display: Where should this link go? Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS adamm mover ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL VB.net Vimscript XML YAML Insert Cancel Save Cancel Associated Messages message string data: Adamm Mover Error: DeviceIo: 00:00:08:00 - Retry Logic: Original settings restored on device: QUANTUM ULTRIUM 4
Jan 15, 2010 Adamm Mover Error: Write Failure! Error = ERROR_CRC Drive = "HP Ultrium" {7820F5AA-1854-49B6-A0A8-D88F3031876C} Media = "000010L3" {AD17CD33-B409-48A9-ADDA-E15C76A597E1} Read Mode: SingleBlock(0), ScsiPass(0) Write Mode: SingleBlock(1), adamm mover error ScsiPass(1) Dec 29, 2010 Adamm Mover Error: GetDriveInfo Failure! Error = ERROR_IO_DEVICE Drive = "Dell DLT" {7A0C1DBD-D245-4FA1-A01D-D9E4B3EB67DD} Media = "" {00000000-0000-0000-0000-000000000000} Read Mode: SingleBlock(0), ScsiPass(0) Write Mode: SingleBlock(1), ScsiPass(1) Nov 21, 2011 Adamm Database Error: Driver Connect Failure! Error = ERROR_DATABASE_DOES_NOT_EXIST Server = "ESTER" Active Node = "" Instance = "BKUPEXEC" Database = "BEDB" May 15, 2013 Comments Pure Capsaicin May 26, 2011 peter Non Profit, 101-250 Employees all help greatly appreciated Pimiento Jul 18, 2011 Craig1286 Manufacturing We have found with this that power cycling the tape drive resolves this issue. Probably indicating that there is a loss of comms with the SCSI device Add your comments on this Windows Event! Join the IT Network or Login. Stats Reported 7 years ago 2 Comments 7,460 Views Others from Backup Exec 34113 57755 33808 33919 58068 57476 57860 34114 See More IT's easier with help Join millions of IT pros working smarter and faster together COMMUNITY STATS 200K+ 10K+ 5M+ Product Reviews How-tos & Scripts Posts Connect with OR Join - It's Free Have an account? Login By creating an account, you're agreeing to our Terms of Use and our Privacy Policy © Copyright 2006-2016 Spiceworks Inc. About Advertising Privacy Terms Help Sitemap × Join millions of IT pros like you Log in to Spicewo