script outputs the product breadcrumb required for edocs documentation. > Message Index (by Number) (by Subsystem) > BEA-Reporting Subsystem Messages BEA-Reporting Subsystem Messages The BEA-Reporting catalog contains messages hayward aqua logic troubleshooting in the range BEA473500 - BEA473599. Messages in this catalog are part of goldline controls aqua logic the com.bea.wli.reporting.jmsprovider Internationalization package and the com.bea.wli.reporting.jmsprovider Localization package. BEA-473500 Error: JMS Reporting Data Manager failed to deploy during aqua logic configuration menu locked server start up ex Description The JMS Reporting Data Manager failed to deploy during server start up. This could be caused by insufficient Security privileges, missing Reporting Tables, or a lost Database
Goldline Aqua Logic Circuit Board
Connection. Cause JMS Reporting Data Manager failed to deploy successfully. Action Please verify the users Security privileges and the existence of Reporting Tables and/or a Database Connection If there are no Reporting Tables, please run the JMS Reporting Provider Database Script. BEA-473501 Error: The JMS Reporting Data Manager failed to undeploy ex Description There was a problem with undeployment: all of the messages goldline aqua logic reset were already processed. Cause The JMS Reporting Data Manager failed to undeploy. Action Please contact BEA Support with your log details. BEA-473502 Error: Message reports are not persisted in the Reporting Table for MSG_GUID = messageId ex Description Message Reports are not persisting in the Reporting Table. Cause An unexpected error occurred when creating insert statement for message reports. There should be an error message that points to cause of the problem. Action Please contact BEA Support with your log details. BEA-473503 Error: A SQL Exception occurred during Message Reporting. Persistence with the SQL State is sqlState and the Error Code is ErrorCode ex Description A SQL Exception occurred while Message Reports were being inserted into the Message table. Cause The Exception was caused by a Database failure. Action Please refer to the log for the source of the failure or contact BEA Support. BEA-473504 Error: The JMS Report Data Handler failed to send the message to the JMS Queue : message ex Description The JMS Report Data Handler failed to send a message to the JMS Queue. Cause There may be no JMS Connection Factory or the
longer working. This website details the steps involved in correcting this error.When the error first appeared I did a quick Google aqua logic check system light search and found a thread of messages on GardenWeb.com with several other Hayward
Aqua Logic No Cell Power
Aqualogic owners reporting the same problem.The problem appeared to be the main board and was going to cost between $500-$900
Aqua Logic Low Salt Reading
to repair -- until navyet posted his findings. Navyet reported that he removed the main board and found a melted solder joint on the back of K1. He resoldered the joint and it https://docs.oracle.com/cd/E13171_01/alsb/docs30/messages/alsb/modules/reporting/l10n/JmsReportingProvider.html worked like a charm.Since then several users, including me, have reported similar success.These are the steps I took to resolve the error. It may not work for you. Following these instructions could lead to expensive pool repairs, electrocution, and death. Use at your own risk.You can contact me at nocellpower at dahlkids dot com.UpdateRead a letter from a Hayward/Goldline Warranty station!If you have success (or http://nocellpower.blogspot.com/2009/05/no-cell-power-on-hayward-aqualogic.html failure) leave a comment to this post. Have comments, tips, or additional information about this step? Leave a comment and share your knowledge. 73 comments: adsMay 14, 2009 at 6:12 PMThank you, Thank you, Thank you! Same exact problem. Called Aqualogic, they told me to check the 20A fuse. When I confirmed the fuse wasn't blown they told me to contact my pool company since they were an approved warranty provider for Aqualogic. Decided to Google this first and found this link. Took the board off, and found the same burned out connection under the relay. Soldered it back and Presto, works like new!Thanks,MichaelReplyDeleteRepliesGiulio LanciaMay 12, 2013 at 1:52 PMHave same problem thi morning after lot trouble shutting I find the solar valve motore was wet and corrode short out 20amp fuse is to protect all valve 24 volt Easy way to look for problem by 4 new fuse disconnect all valve and replace the fuseDeleteReplyLaura WMay 22, 2009 at 2:58 PMBless you! Bless you! Bless you! As a single mom of two kids...the $800 it was going to cost to "fix and replace" this issue had been causing me stress since my "no