replies Latest Post - 2013-04-30T17:05:48Z by matthewpmattson Display:ConversationsBy Date 1-3 of 3 Previous Next matthewpmattson 2700067GGT 2 Posts Pinned topic Tracing SC_DISK_ERR4 2013-04-29T20:42:45Z | Tags: aix disk operation error Answered question This question has been answered. Unanswered question This question
Sc_disk_err4
has not been answered yet. Hi all, I have some AIX hosts connected via SAN to a de3b8540 3PAR storage array and while running I/O on the disks I am seeing some TEMP errors in my errpt. See below for full details: from the errpt -c sc_disk_err7 command DCB47997 0429144313 T H hdisk1 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk11 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk11 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk20 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk4 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk15 DISK OPERATION ERROR DCB47997 0429144313 T H hdisk15 DISK OPERATION ERROR
Sc_disk_err9
DCB47997 0429144313 T H hdisk5 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk2 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk2 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk13 DISK OPERATION ERROR DCB47997 0429144413 T H hdisk13 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk17 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk17 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk16 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk5 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk5 DISK OPERATION ERROR DCB47997 0429144513 T H hdisk2 DISK OPERATION ERROR DCB47997 0429144613 T H hdisk1 DISK OPERATION ERROR detail of the error: --------------------------------------------------------------------------- LABEL: SC_DISK_ERR4 IDENTIFIER: DCB47997 Date/Time: Sun Apr 28 22:14:51 CDT 2013 Sequence Number: 33081 Machine Id: 00F7A89E4C00 Node Id: blue7 Class: H Type: TEMP WPAR: Global Resource Name: hdisk18 Resource Class: disk Resource Type: 3PAR_VV_MPIO Location: U8231.E1C.06A89ER-V1-C35-T1-W20210002AC0185E0-L12000000000000 VPD: Manufacturer................3PARdata Machine Type and Model......VV Serial Number...............C000009900000000 Description DISK OPERATION ERROR Probable Causes MEDIA DASD DEVICE User Causes MEDIA DEFECTIVE Recommended Actions FOR REMOVAB
CenterInternet of Things News and EventsConnectDeveloper NetworkPartner CommunitiesGlobal Accounts and GSI CustomersMember DirectoryMy CommunityMy GroupsSpaces I FollowContentBookmarksLog in0SearchSearchSearchCancelError: You don't have JavaScript enabled. aix fcp_err4 This tool uses JavaScript and much of it will not aix sc_disk_err9 work correctly without it enabled. Please turn JavaScript back on and reload this page. Please enter a title. You can not post a blank message. Please type your message and try again. More discussions in Solution and Product Forums Where https://www.ibm.com/developerworks/community/forums/html/topic?id=43abe789-d952-4458-bb99-cdf562ebc5a3 is this place located?HDS CommunityAll PlacesSolution and Product Forums 1 Reply Latest reply on Jun 7, 2013 8:33 PM by Legacy HDS Forums Temp disk errors in AIX cause oracle to hang and dlm commands to hang Legacy HDS Forums Jun 7, 2009 6:23 AM Originally posted by: PP BIJU KRISHNANI https://community.hds.com/thread/2065 have been having sleepless nights for the past few months due to the following issuesCommon System specsAIX 5.3 TL06 and TL08HDLM 5.81.2.1USP-VSAN - Brocade 4100/4900/48K - FOS 6.1.0c--------------------------------------------------------------------------------------------------------------The foll type of AIX errors cause oracle to hangDCB47997 0605201809 T H hdisk42 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk31 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk38 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk37 DISK OPERATION ERROR DCB47997 0605201809 T H hdisk13 DISK OPERATION ERROR DCB47997 0604070809 T H hdisk125 DISK OPERATION ERROR LABEL: SC_DISK_ERR4IDENTIFIER: DCB47997Date/Time: Thu Jun 4 07:08:17 CUT 2009Sequence Number: 1095955Machine Id: 00CE6CDE4C00Node Id: pat2047Class: HType: TEMPResource Name: hdisk250Resource Class: diskResource Type: HitachiLocation: U7311.D20.6555C3B-P1-C03-T1-W50060E800545321A-L4A000000000000VPD: Manufacturer................HITACHI Machine Type and Model......OPEN-V Part Number................. ROS Level and ID............36303033 Serial Number...............50 04532 EC Level.................... FRU Number.................. Device Specific.(Z0)........00000332CF000002 Device Specific.(Z1)........3D14 2L .... Device Specific.(Z2).........0== Device Specific.(Z3)......... Device Specific.(Z4).........Z.. Device Specific.(Z5)........ Device Specific.(Z6)........DescriptionDISK OPERATION ERRORProbable CausesMEDIADASD DEVICEUser CausesMEDIA DEFECTIVE Recommended Actions FO
system that meets the demands of applications that businesses rely upon in today's marketplace. Search Forums Show Threads Show Posts Tag Search Advanced Search Unanswered Threads Find All Thanked Posts Go to Page... learn http://www.unix.com/aix/62848-disk-operation-error.html linux and unix commands - unix shell scripting Disk operation Error AIX Tags aix, unix https://community.emc.com/thread/174632?start=0&tstart=0 Thread Tools Search this Thread Display Modes #1 04-27-2008 cabloy Registered User Join Date: Apr 2008 Last Activity: 2 April 2009, 6:51 AM EDT Posts: 2 Thanks: 0 Thanked 0 Times in 0 Posts Disk operation Error Hi to all, Hope you can help me to figure out this disk operation problem that I have with one of our servers. I get disk errors but I cannot explain the reason why it is happening. Below is the error: Thanks in advance. By the way were using NETAPPS data storage and using 5.3 O.S version. LABEL: SC_DISK_ERR4 IDENTIFIER: DCB47997 Date/Time: Sun Apr 27 17:03:06 TAIST 2008 Sequence Number: 91540 Machine Id: 00C8E11B4C00 Node Id: IBMTEST2 Class: H Type: TEMP Resource Name: hdisk47 Resource Class: disk Resource disk operation error Type: NetAppMPIO Location: U5791.001.99B075F-P2-C09-T1-W500A098197A93A68-LF000000000000 VPD: Manufacturer................NETAPP Machine Type and Model......LUN ROS Level and ID............0.2 Serial Number...............HnScTJACY12y Device Specific.(Z0)........FAS3070 Description DISK OPERATION ERROR Probable Causes MEDIA DASD DEVICE User Causes MEDIA DEFECTIVE Recommended Actions FOR REMOVABLE MEDIA, CHANGE MEDIA AND RETRY PERFORM PROBLEM DETERMINATION PROCEDURES Failure Causes MEDIA DISK DRIVE Recommended Actions FOR REMOVABLE MEDIA, CHANGE MEDIA AND RETRY PERFORM PROBLEM DETERMINATION PROCEDURES Detail Data PATH ID 0 SENSE DATA 0A00 2800 0A6B 2F60 0000 2004 0000 0000 0000 0000 0000 0000 0200 0300 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0039 2D8D 0002 52C0 0000 0010 0000 0000 0000 0000 0000 0083 0000 0000 0035 001D --------------------------------------------------------------------------- LABEL: SC_DISK_ERR4 IDENTIFIER: DCB47997 Date/Time: Sun Apr 27 16:27:17 TAIST 2008 Sequence Number: 91539 Machine Id: 00C8E11B4C00 Node Id: IBMTEST2 Class: H Type: TEMP Resource Name: hdisk51 Resource Class: disk Resource Type: NetAppMPIO Location: U5791.001.99B075F-P2-C09-T1-W500A098197A93A68-L18000000000000
Management Converged Platforms Data Protection Infrastructure Management Platform Solutions Security Storage Dell Products for Work Network Servers Education Partners Programs Highlighted Communities Support » Connect » Developers » Partners » Downloads » 日本語コミュニティ EMC Community Dell Community A AppSync Application Xtender Atmos Avamar C Captiva Celerra Centera CLARiiON Cloud Tiering Appliance Connectrix D Data Domain Data Protection Advisor Disk Library DiskXtender Documentum E ECS eRoom G Greenplum H Host Systems I InfoArchive Isilon ISIS Document Imaging L Leap N NetWorker P PowerPath Prosphere R RecoverPoint Replication RSA S ScaleIO Secure Remote Smarts SourceOne & EmailXtender EMC Storage Analytics Symmetrix U Unity V ViPR Controller Product Communities > VMAX > Discussions Please enter a title. You can not post a blank message. Please type your message and try again. 3 Replies Latest reply: May 9, 2013 4:00 AM by Sreekanth K SC_DISK_ERR4 on AIX azhar4uf May 8, 2013 3:46 PM On AIX machine it reported the following error and it reported errors for some disks coming from fscsi2. can we ignore this error messages ?LABEL: SC_DISK_ERR4IDENTIFIER: DCB47997Date/Time: Tue May 7 21:50:42 PDT 2013Sequence Number: 636Machine Id: 00F80D684C00Node Id: hhssvdr246204Class: HType: TEMPWPAR: GlobalResource Name: hdisk61Resource Class: diskResource Type: SYMM_VRAIDLocation: U5802.001.RCHE058-P1-C1-T1-W500009720855A95C-L9000000000000VPD: Manufacturer................EMC Machine Type and Model......SYMMETRIX ROS Level and ID............5876 Serial Number...............82279000 Part Number.................000000000000400957000192 EC Level....................605482 LIC Node VPD...........