Eppendorf 5810 R Error 3
Contents |
and Supplies Cosmetic Defibrillator Dental EMS/Rescue Endoscopy Exam Room Homecare/Rehab Imaging Laboratory Monitors/ICU/CCU Neonatal Neurology Ophthalmology Physical Therapy Pumps Radiation Therapy Respiratory Sterile Processing Surgical Veterinary All Others
Eppendorf 5810r Service Manual
Parts Beds, Stretchers and Furniture Cardiology Consumables and Supplies Cosmetic Defibrillator Dental eppendorf centrifuge error 16 EMS/Rescue Endoscopy Exam Room Homecare/Rehab Imaging Laboratory Monitors/ICU/CCU Neonatal Neurology Ophthalmology Physical Therapy Pumps Radiation Therapy Respiratory
Eppendorf Centrifuge Manual
Sterile Processing Surgical Veterinary All Others Service Auctions News Home Forums Careers/Training Forums EquipmentPartsPeopleCompaniesServicesEquipment GuideForumsNewsTraining SEARCH New Listings Post Listing Post Auction Advertise Current Location:Virtual Trade Show eppendorf 5804 > Forums > Service Technicians > centrifuge 5804r showing error 3
centrifuge 5804r showing error 3 I'm sorry, there is a problem with your post, please Log-In to DOTmed to continue Tweet (2) Bubacarr Sissoko centrifuge 5804r showing error 3 August 20, 2014 08:25 My Eppendorf centrifuge 5804R showing no rotor and error 3 when start is pressed. eppendorf centrifuge 5430 manual The rotor dont move at all but can hear the compressor sound when press start. Please help. Log inor Register to rate and post a comment (3) (9) David Jensen re: centrifuge 5804r showing error 3 August 21, 2014 12:51 Here is what the service manual says about error 3 Error 3 no rotor No rotor pulses during run or acceleration. Missing rotor, measuring system for rotational speed defective, drive defective. – Rotor not fastened. – No pulses after start. Device brakes for 15 s. – Pulse failure during run. Free deceleration requires 12 min! Error remains active after a power supply interruption. – Fasten rotor. Keep device switched on and start again after > 12 min. – Service program 8. – Check/replace motor cap with speed sensor, check connections. – Replace "Control/FC" PCB, check connector X10 on PCB "Control". – Check run of motor, replace motor if necessary. Log inor Register to rate and post a comment (2) Long Nguyen Kim re: re: centrifuge 5804r showing error 3 September 07, 2016 12:13 MyText mode Original mode 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
Eppendorf 5804r Manual
52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 eppendorf centrifuge 5804 r 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94
Eppendorf Swing Bucket Centrifuge
95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 Advertising 69 Centrifuge 5804/5804 R/5810/5810 R — Operating manual 8.4 https://www.dotmed.com/virtual-trade-show/category/Service-Technicians/Discussions/Forums/Centrifuge-5804r-Showing-Error-3/51336 Emergency release If the centrifuge lid cannot be opened, you can activate the emergency release manually. You need the standard rotor key supplied with the centrifuge. 1. Disconnect the power plug.2. Remove the plastic cover for the emergency release. This is located in the center on the front side of the device. 3. Insert the rotor key into the hexagonal opening behind until some resistance can be felt.4. While keeping the rotor key pressed, turn it in a counterclockwise direction. This will release the centrifuge lid. 5. http://www.manualsdir.com/manuals/551246/eppendorf-5810-r-centrifuge-5810-centrifuge-5804-r-centrifuge-5804-centrifuge.html?page=69 Open the centrifuge lid.6. Remove the rotor key and put the plastic covers back on. Error 3 Error in speed measuring system. Insert rotor and screw tight. Error 3 Error in speed measuring system. Allow the centrifuge to stand for 12 min when switched on until the open key lights up. Error 4 Lid latch sensor faulty. Switch the centrifuge off and back on again after > 20 s. Error 5 Prohibited opening of lid or lid switch is defective during a run. 1. Wait for rotor to stop.2. Open and close again the lid of the device. 3. Repeat the run. Error 6 or overload Mains voltage too low. Check the mains voltage. Error 6 or overload • Converter overloaded. • Brake faulty. Switch off centrifuge, allow to cool down for at least 5 min, and then switch on again. Error 8 • Drive fault. • Rotor loose. • Motor defective. 1. Wait for rotor to stop.2. Tighten the rotor.3. Repeat the run. Error 9 to Error 25 Electronics fault. Switch the centrifuge off and back on again after > 20 s. Symptom/message Cause Remedy WARNING! Risk of injury from rotating rotor. Wait until the rotor has come to a standstill before you operate the emergency release. The rotor can continue rotating for up to 8 min. To check, look through the inspection glass in the centrifuge lid. EN Operating manual Share Pages: 1 … 67 68 69 70 71 … 127 Download Complain wrong Brand wrong
Used Ask a Question Write a Review Share: Description Features Photos (1) Documents (1) Centrifuge 5810 / 5810 R Eppendorf Centrifuge Model 5810 / http://www.medwrench.com/?equipment.view/equipmentNo/2478/EPPENDORF/Centrifuge-5810---5810-R/ Refrigerated Model 5810 R Unparalleled versatility Featuring powerful, maintenance-free motors, these models accommodate a variety of rotors to meet your application needs. They are three centrifuges in one: a high-capacity, general-purpose centrifuge for cell harvesting; a high-speed centrifuge for separating cell lysates; and a microcentrifuge for DNA precipitations. Model 5810 and refrigerated Model 5810 R* offer maximum application versatility and popular tube capacity, accommodating up eppendorf centrifuge to 4 x 400 ml tubes or 16 microplates. These compact, benchtop centrifuges achieve remarkable throughput of up to 48 x 15 ml or 20 x 50 ml conical (Falcon®) tubes Centrifuge 5810 / 5810 R Attributes Additional Specifications Maximum power requirement: (5810) 900 W (5810 R) 1,650 W Dimensions (W x D x H): (5810) 21 x 24 x 13 eppendorf 5810 r in (5810 R) 28 x 24 x 13 in Weight:(5810) 150 lb/68 kg (5810 R) 218 lb/99 kg Features Interchangeable swingbucket and high-speed fixedangle rotors Spin up to 14,000 rpm, or 20,800 x g Low-profile 11.2 in/28 cm access height for easy sample loading Automatic rotor recognition senses rotor type to set maximum allowable speed—ensures safety Fast, simple programming of time, temperature (refrigerated models), speed/ g-force and radius value 34 user-defined programs Adjustable-speed Short Spin button Ten acceleration and braking rates Simple operation Speed, g-force and radius correction values can be entered Values can be changed during centrifugation Temperature range from –9 °C to 40°C, with Fast Temp function for rapid cooling of the centrifuge chamber Standby cooling maintains temperature when not in use Speed can be set from 200 rpm to maximum speed in increments of 10 rpm Short Spin button Selectable program memory for up to 34 individual user programs Ten acceleration and deceleration rates for sensitive sample material Photos 5810 / 5810 R Manuals and Resources Note: We appreciate the support of individuals and companies making their documents and resou
be down. Please try the request again. Your cache administrator is webmaster. Generated Sat, 08 Oct 2016 13:57:58 GMT by s_ac4 (squid/3.5.20)