and Supplies Cosmetic Defibrillator Dental EMS/Rescue Endoscopy Exam Room Homecare/Rehab Imaging Laboratory Monitors/ICU/CCU Neonatal Neurology Ophthalmology Physical Therapy Pumps Radiation Therapy Respiratory Sterile Processing Surgical Veterinary All Others Parts Beds, Stretchers and Furniture Cardiology Consumables and Supplies Cosmetic Defibrillator Dental EMS/Rescue Endoscopy
Eppendorf Centrifuge 5424 R Error 6
Exam Room Homecare/Rehab Imaging Laboratory Monitors/ICU/CCU Neonatal Neurology Ophthalmology Physical Therapy Pumps Radiation Therapy 5804r eppendorf centrifuge manual Respiratory Sterile Processing Surgical Veterinary All Others Service Auctions News Home Forums Careers/Training Forums EquipmentPartsPeopleCompaniesServicesEquipment GuideForumsNewsTraining SEARCH New Listings Post Listing 5810r centrifuge manual Post Auction Advertise Current Location:Virtual Trade Show > Forums > Service Technicians > centrifuge 5804r showing error 3
centrifuge 5804r showing error 3 I'm sorry, there is a problem with your post, please Log-InEppendorf Centrifuge 5804r Rpm To G
to DOTmed to continue Tweet (2) Bubacarr Sissoko centrifuge 5804r showing error 3 August 20, 2014 08:25 My Eppendorf centrifuge 5804R showing no rotor and error 3 when start is pressed. The rotor dont move at all but can hear the compressor sound when press start. Please help. Log inor Register to rate and post a comment (3) (9) David Jensen re: centrifuge 5804r showing error 3 August 21, 2014 12:51 Here is
Eppendorf 5804 Manual
what the service manual says about error 3 Error 3 no rotor No rotor pulses during run or acceleration. Missing rotor, measuring system for rotational speed defective, drive defective. – Rotor not fastened. – No pulses after start. Device brakes for 15 s. – Pulse failure during run. Free deceleration requires 12 min! Error remains active after a power supply interruption. – Fasten rotor. Keep device switched on and start again after > 12 min. – Service program 8. – Check/replace motor cap with speed sensor, check connections. – Replace "Control/FC" PCB, check connector X10 on PCB "Control". – Check run of motor, replace motor if necessary. Log inor Register to rate and post a comment (2) Long Nguyen Kim re: re: centrifuge 5804r showing error 3 September 07, 2016 12:13 My Eppendorf centrifuge 5415R showing Error 3 and can not control anything when I turned the switched on. Please help me fix this error! Thanks! Log inor Register to rate and post a comment (3) (9) David Jensen re: centrifuge 5804r showing error 3 August 21, 2014 12:51 Error 3 Cause no rotor No rotor pulses during run or acceleration. Missing rotor, measuring system for rotational speed defective, drive defective. – Rotor not fastened. – No pulses after start. Device brakes for 15 s. – Pu
Text mode Original mode 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 eppendorf centrifuge 5810r rotor radius 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67
Eppendorf Centrifuge 5810r Rotor A-4-62
68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 eppendorf centrifuge 5810 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 Advertising 69 Centrifuge 5804/5804 R/5810/5810 R — Operating manual https://www.dotmed.com/virtual-trade-show/category/Service-Technicians/Discussions/Forums/Centrifuge-5804r-Showing-Error-3/51336 8.4 Emergency release If the centrifuge lid cannot be opened, you can activate the emergency release manually. You need the standard rotor key supplied with the centrifuge. 1. Disconnect the power plug.2. Remove the plastic cover for the emergency release. This is located in the center on the front side of the device. 3. Insert the rotor key into the hexagonal opening behind until some resistance can be felt.4. While keeping the rotor key pressed, turn it in a counterclockwise direction. This will release the http://www.manualsdir.com/manuals/551246/eppendorf-5810-r-centrifuge-5810-centrifuge-5804-r-centrifuge-5804-centrifuge.html?page=69 centrifuge lid. 5. Open the centrifuge lid.6. Remove the rotor key and put the plastic covers back on. Error 3 Error in speed measuring system. Insert rotor and screw tight. Error 3 Error in speed measuring system. Allow the centrifuge to stand for 12 min when switched on until the open key lights up. Error 4 Lid latch sensor faulty. Switch the centrifuge off and back on again after > 20 s. Error 5 Prohibited opening of lid or lid switch is defective during a run. 1. Wait for rotor to stop.2. Open and close again the lid of the device. 3. Repeat the run. Error 6 or overload Mains voltage too low. Check the mains voltage. Error 6 or overload • Converter overloaded. • Brake faulty. Switch off centrifuge, allow to cool down for at least 5 min, and then switch on again. Error 8 • Drive fault. • Rotor loose. • Motor defective. 1. Wait for rotor to stop.2. Tighten the rotor.3. Repeat the run. Error 9 to Error 25 Electronics fault. Switch the centrifuge off and back on again after > 20 s. Symptom/message Cause Remedy WARNING! Risk of injury from rotating rotor. Wait until the rotor has come to a standstill before you operate the emergency release. The rotor can continue rotating for up to 8 min. To check, look through the inspection glass in the centrifuge lid. EN Operating manual Share Pages: 1 … 67 68 69 70 71 … 127
Active Topics FAQ Topic Options Rate This Topic #66717 - 28/01/14 03:07 PM Eppendorf 5810R Error 6 Warwick22 Newbie Registered: 28/01/14 http://www.ebme.co.uk/forums/ubbthreads.php/topics/66729/Re:_Eppendorf_5810R_Error_6 Posts: 1 Loc: Staffordshire UK I am a 'volunteer' technician and regularly repair/service Lab equipment for a charitably-funded reasearch fund.I need to find a service manual for an Eppendorf 5810R (older model) or someone who knows what the fix is for an "Error 6"-Eppendorf won't help (no longer supported)Can anyone out there assist?Please? Top #66726 - 28/01/14 eppendorf centrifuge 08:30 PM Re: Eppendorf 5810R Error 6 [Re: Warwick22] Geoff Hannis Super Hero Registered: 12/02/04 Posts: 12741 Loc: the path less trodden Welcome to the forum, Warwick. Try a Google search ... Error 6 for this centrifuge gets a fair few mentions. Top #66729 - 29/01/14 05:06 PM Re: Eppendorf 5810R Error 6 [Re: Warwick22] Pierre-Luc Dreamer Registered: eppendorf centrifuge 5810 02/05/13 Posts: 22 Loc: Quebec, Canada overloadorError 6Converter overloaded.Brake defective.Voltage supply too low.Rotor becomes loose.Allow to cool. Restart device after 5 min.Check voltage supply.Tighten rotor. Top Previous Topic Index Next Topic Preview Hop to: website ------EBME WebsiteSite NewsEventsGallerymanagement ------Modernisation (formerly... Controls Assurance)Equipment librariesSales - Wanted - ExchangesMedical Equipment ManagementTraining IssuesLost and Foundmaintenance ------Test EquipmentSpare partsService ManualsGeneral assistanceTechnical assistanceService InfoBiomed databasessponsors ------Innovation & You.free discussion ------Free discussionOut of HoursAgenda For ChangeProfessional IssuesTechnologyNursing Issuesrecruitment ------VacanciesAvailable for work Moderator: DaveC in Oz, KM, RoJo Print Topic Switch to Threaded Mode View profileSend a PMAdd to your Watched UsersView postsView profileSend a PMAdd to your Watched UsersView postsView profileSend a PMAdd to your Watched UsersView posts Who's Online 2 registered (Huw, hrsoltani), 6 Guests and 0 Spiders online. Key: Admin, Global Mod, Mod Events October M Tu W Th F Sa Su 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Forum St
be down. Please try the request again. Your cache administrator is webmaster. Generated Mon, 10 Oct 2016 02:03:57 GMT by s_ac15 (squid/3.5.20)