Precision Error Measuring Cylinder
Contents |
error'). Experimental uncertainty arises because of: Limits in the how exact the measuring apparatus is. This is the precision of the apparatus. Imperfections in experimental procedures. Judgements made uncertainty of measuring cylinder by the operator. When can my results be said to be precise? If
Percentage Error Of Burette
you repeat a measurement several times and obtain values that are close together, your results are said to be precise. If
Percentage Error Of Equipment
the same person obtains these close values, then the experimental procedure is repeatable. If a number of different people carry out the same measuring procedure and the values are close the procedure is reproducible.
Uncertainty Of Measuring Cylinder 100ml
What is a systematic error? A systematic error is one that is repeated in each measurement taken. If this is realised after the experimental work is done, it can be taken into account in any calculations. What are random errors? Even the most careful and experienced operator cannot avoid random errors. However, their effect can be reduced by carrying out a measurement many times (if the opportunity exists) and percentage error of measuring cylinder working out an average value. Let's look in more detail at 'built-in' uncertainty of some laboratory equipment... Some measurement uncertainties are given below: EquipmentMeasurement to the nearest: Balance (1 decimal place)0.08 g Balance (2 decimal place)0.008 g Balance (3 decimal place)0.0008 g Measuring Cylinder (25 cm3)0.5 cm3 Graduated Pipette (25 cm3, Grade B)0.04 cm3 Burette (50 cm3, Grade B)0.08 cm3 Volumetric Flask (250 cm3, Grade B)0.2 cm3 Stopwatch (digital)0.01 s Calculating the percentage uncertainty (often called percentage error) ... Now try calculating the following percentage uncertainties... 1.00 g on a 2 decimal place balance 10.00 g on a 2 decimal place balance 1.00 g on a 3 decimal place balance 10 cm3 in a 25 cm3 measuring cylinder 25 cm3 in a 25 cm3 measuring cylinder 25 cm3 in a 25 cm3 graduated pipette (Grade B) 25 cm3 in a 50 cm3 burette (Grade B) 250 cm3 in a 250 cm3 volumetric flask (Grade B) 50 s on a digital stopwatch 8% 0.8% 0.08% 5% 2% 0.16% 0.32% 0.08% 0.02% Comparing uncertainties like those calculated above 'might' help you to decide which stage in an experimental procedure is likely to contribute most to the overall experimental uncertainty. How about thermometers...? Spirit filled thermometers are regularly
ERROR - Pawan Posted by Pawan on Dec 14, 2011 in Physical Chemistry | 1 comment Apparatus Errors Every time you make a measurement percentage error of 25cm3 pipette with a piece of apparatus, there is a small margin of error 100 cm3 measuring cylinder uncertainty in that measurement due to the apparatus itself. For example, no balance can measure an exact mass measuring cylinder error but a very expensive and precise balance may be able to measure a mass to the nearest 0.0001 g, while a cheaper, less precise balance may only measure http://www.avogadro.co.uk/miscellany/errors.htm it to the nearest 0.1 g. Errors such as this are known as apparatus error and cannot be avoided, although they can be reduced by using the most precise equipment available. For example, when measuring out 25 cm3 of a solution, a pipette is much more precise than a measuring cylinder. When you do quantitative experiments (those http://www.alevelhelp.com/2011/12/apparatus-error-experimental-error/ that require you to measure a quantity), you will have to calculate the total apparatus error from the sum of the apparatus error for each piece of equipment you use to make a measurement. Apparatus error for each piece of equipment = 100 x (margin of error)/(quantity measured) For example, imagine a pupil doing an experiment where she measured out 1.245 g of a base, make it up to 250 cm3 of solution in a volumetric flask, pipetted 25 cm3 of that solution into a conical flask, and then found that it reacted with 23.30 cm3 of acid in a titration using a burette. Balance (± 0.001 g) 100 x (0.001/1.245) = 0.08% Pipette (± 0.1 cm3) 100 x (0.1/25) = 0.40% Volumetric flask (± 0.1 cm3) 100 x (0.1/250) = 0.04% Burette (± 0.15 cm3) 100 x (0.15/23.30) = 0.64% Total apparatus error = 1.16% This means that the result of the experiment should be within 1.16% of the correct value. When you design experiments