Phoenix Bios Post Error Beep Codes
Contents |
Eurosoft/Mylex Faraday A-Tease HP IBM Landmark Microid Research/Mr NCR Olivetti Phillips Phoenix Quadtel Supersoft Tandon Zenith Intel Motherboards: CA810E CC820 SE440BX-2 D810E2CB D810EMO D815BN D815EEA D815EPEA D820LP SE440BX SR440BX JN440BX LB440GX/L440GX N440BX/NA440BX OR840 T440BX RC440BX VC820 Phoenix ISA/MCA/EISA BIOS phoenix bios beep codes Beep Codes: The beep codes are represented in the number of beeps. E.g. 1-1-2
Asus Beep Codes
would mean 1 beep, a pause, 1 beep, a pause, and 2 beeps. With a Dell computer, a 1-2 beep code can gigabyte beep codes also indicate that a bootable add-in card is installed but no boot device is attached. For example, in you insert a Promise Ultra-66 card but do not connect a hard drive to it, you will phoenix bios continuous beep get the beep code. I verified this with a SIIG (crap -- avoid like the plague) Ultra-66 card, and then confirmed the results with Dell. Submitted by John Palmer. Beeps Error Message Description 1-1-2 CPU test failure The CPU is faulty. Replace the CPU Low 1-1-2 System board select failure The motherboard is having an undetermined fault. Replace the motherboard 1-1-3 CMOS read/write error The real time clock/CMOS is faulty. Replace
Hp Beep Codes
the CMOS if possible Low 1-1-3 Extended CMOS RAM failure The extended portion of the CMOS RAM has failed. Replace the CMOS if possible 1-1-4 BIOS ROM checksum error The BIOS ROM has failed. Replace the BIOS or upgrade if possible 1-2-1 PIT failure The programmable interrupt timer has failed. Replace if possible 1-2-2 DMA failure The DMA controller has failed. Replace the IC if possible 1-2-3 DMA read/write failure The DMA controller has failed. Replace the IC if possible 1-3-1 RAM refresh failure The RAM refresh controller has failed 1-3-2 64KB RAM failure The test of the first 64KB RAM has failed to start 1-3-3 First 64KB RAM failure The first RAM IC has failed. Replace the IC if possible 1-3-4 First 64KB logic failure The first RAM control logic has failed 1-4-1 Address line failure The address line to the first 64KB RAM has failed 1-4-2 Parity RAM failure The first RAM IC has failed. Replace if possible 1-4-3 EISA fail-safe timer test Replace the motherboard 1-4-4 EISA NMI port 462 test Replace the motherboard 2-1-1 64KB RAM failure Bit 0; This data bit on the first RAM IC has failed. Replace the IC if possible 2-1-2 64KB RAM failure Bit 1; This data bit on the first
Eurosoft/Mylex Faraday A-Tease HP IBM Landmark Microid Research/Mr NCR Olivetti Phillips Phoenix Quadtel Supersoft Tandon Zenith Intel Motherboards: CA810E CC820 SE440BX-2 D810E2CB D810EMO D815BN D815EEA D815EPEA D820LP SE440BX SR440BX JN440BX LB440GX/L440GX N440BX/NA440BX OR840 T440BX RC440BX VC820 Phoenix BIOS Text Error Messages Phoenix BIOS Post Procedures award bios beep codes Phoenix XT 2.52 PnP BIOS Post Codes Phoenix BIOS Plus or v1.0 BIOS Post Codes Phoenix phoenix bios beep codes 1-3-4-3 UMC chipset PCI BIOS Post Codes Phoenix PCI BIOS Post Codes Phoenix ISA/EISA/MCA v3.07 BIOS Post Codes Phoenix 4.0 BIOS Post Codes Phoenix 4.0
Intel Beep Codes
Release 6.0 BIOS Post Codes Phoenix BIOS Text Error Messages: Diskette drive A error Drive A: is present but fails the POST diskette tests. Check that the drive is defined with the proper diskette type in Setup and http://www.bioscentral.com/beepcodes/phoenixbeep.htm that the disk is installed correctly Extended RAM failed at offset: nnn Extended memory not working or not configured properly at offset: nnn Failing Bits: nnnn The hexadecimal number nnnn is a map of the bits at the RAM address that failed the memory test. Each 1 in the map indicates a failed bit Fixed Disk 0 Failure Fixed disk is not working or not configured properly. Check to see if fixed disk is installed properly. Run Setup http://www.bioscentral.com/postcodes/phoenixbios.htm to be sure the fixed disk type is correctly identified Fixed Disk 1 Failure Fixed disk is not working or not configured properly. Check to see if fixed disk is installed properly. Run Setup to be sure the fixed disk type is correctly identified Fixed Disk Controller Failure Fixed disk is not working or not configured properly. Check to see if fixed disk is installed properly. Run Setup to be sure the fixed disk type is correctly identified Incorrect Drive A: type - run Setup Type of diskette for drive A: not correctly identified in Setup Invalid NVRAM media type Problem with NVRAM (CMOS) access Keyboard controller error The keyboard controller failed test. Try replacing the keyboard Keyboard error Keyboard not working Keyboard error nn BIOS discovered a stuck key and displays the scan code nn for the stuck key Keyboard locked - Unlock key switch Unlock the system to proceed Monitor type does not match CMOS - Run Setup Monitor type not correctly identified in Setup Operating system not found Operating system cannot be located on either A: or C:. Enter Setup and see if fixed disk and drive A: are properly identified Parity Check 1 Parity error found in the system bus. BIOS attempts to locate the address and display it on screen. If it cannot locate the address, it displays ??? Parity Check 2 Parity error found in th