License Error 26 Proe
& Derivatives Electrical Engineering Algebra & Geometry Math Homework Mechanical Engineering Civil Engineering Statistics & Data Analysis Chemical Engineering Puzzles & Games Physics Windchill CAD Integration Customization FlexPLM Integrity Arbortext Servigistics PTC Academic Program Schools Program University Program FIRST Robotics Real World Design Challenge Academic Support LiveWorx 2016 Browse Content Communities Groups People All Places > Creo > Discussions Please enter a title. You can not post a blank message. Please type your message and try again. 1 Reply Latest reply: Jan 29, 2008 1:19 AM by PaulGriffiths Getting "Unknown Licensing Error :26" ptc-1438319 Jan 28, 2008 12:45 AM Hi All, I am unable to start ProE although the FlexLM license server is correctly installed. I can go through PTCSetup without any problems, but when I try to start ProE, I get 'Unknown Lincensing Error: 26'. Tech support has verified that the licensing settings are correct (The call is still open). I have even trying reinstalling ProE. Has anyone experienced this before? 2471Views Tags: none (add) This content has been marked as final. Show 1 reply Licensing Error 26 PaulGriffiths Jan 29, 2008 1:19 AM (in response to ptc-1438319) Hi Rajeev, Funnily enough, yes! I had exactly the same problem yesterday morning which cost me half a days lost work. I had the same problem, everything looked correctly configured but the LM Server wouldn't start. I logged a call with Tech Supp and they advised me to start PTC Setup again and go through the motions of reinstalling the License Server. Delete the existing License Server and add a new one. Go through the next couple of screens until you get to the last one which has the option of "Additional License Configurations", tick this and add a new License Configuration, mine came up with License Type "Pro/Engineer" and a configuration description of "proe1" which is a batch file that you need to start Pro/E with (make sure your start up Icon points to this batch file). Mine worked fine after this. Paul Like Show 0
FORUMSFOR ENGINEERING PROFESSIONALS Log In Come Join Us! Are you anEngineering professional?Join Eng-Tips Forums! Talk With Other Members Be Notified Of ResponsesTo Your Posts Keyword Search One-Click Access To YourFavorite Forums Automated SignaturesOn Your Posts Best Of All, It's Free! Join Us! *Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Eng-Tips Posting Policies Jobs Link To This Forum! Add Stickiness To Your Site By Linking To This Professionally Managed Technical Forum.Just copy and paste the BBCode HTML Markdown MediaWiki reStructuredText code below into your https://www.ptcusercommunity.com/thread/2846 site. PTC: Creo Parametric (Pro/ENGINEER) Forum at Eng-Tips HomeForumsEngineering Computer ProgramsEngineering ProgramsPTC: Creo Parametric (Pro/ENGINEER) Forum License Request Failed for Function: 26 ???? thread554-227010 Forum Search FAQs Links MVPs License Request Failed for Function: 26 ???? License Request Failed for Function: 26 ???? PCSControls (Mechanical) (OP) 24 Sep 08 10:22 Trying to startup up ProE on a machine that is requesting a floating license from the FlexLM http://www.eng-tips.com/viewthread.cfm?qid=227010 server. I get the error "License Request Failed for Function: 26" and ProE closes.Anyon ehave any clues how to troubleshoot this ? Are there any "FlexLM CLIENT" utilities to help with this ? RE: License Request Failed for Function: 26 ???? dgallup (Automotive) 24 Sep 08 10:56 I would first make sure you can ping the license server.If not you have basic networking problems you need to fix first.If you can ping then I would try running ptcstatus to see the license availability. RE: License Request Failed for Function: 26 ???? PCSControls (Mechanical) (OP) 24 Sep 08 11:34 I can ping without problem. I look on the license server and everything looks OK, Is there any cliient side utils that I can run?I did re-do the PTCSetup and all seems to go OK. But when I start up I still get the same error. RE: License Request Failed for Function: 26 ???? robertib (Mechanical) 25 Sep 08 02:41 If you go through the setup process to the 3rd or 4th tab, there is a checkbox for Additional license configutations.Check that box and the next tab has the startup settings.Click on the 1st (probably only) license type, and click Edit.This will show you all availabl
starting at -1. FLEXnet Licensing Error Text-short sentence (< 80 characters) summarizing problem. FLEXnet Licensing Error Explanation (optional)-short paragraph (3-5 lines) explaining problem and possible solutions or workarounds. FLEXnet Licensing Minor Error Number-a positive number starting at 1. http://media.3ds.com/support/simulia/public/flexlm108/EndUser/chap13.htm These numbers are unique error identifiers and are used by FLEXnet Licensing vendors http://helpproe.blogspot.com/2011/05/7-reasons-why-this-happens-license-not.html for more advanced support assistance. Their meaning is not documented. System Error Number (optional)-a UNIX or Windows OS error code last set by the operating system. System Error Explanation (optional)-a short sentence (< 80 characters) explaining the system error. Other supporting information (optional) Error messages were improved in v6. FLEXnet Licensing Error Explanation, license error and supporting information are only available in applications using v6.0+. These error messages may occur in two formats available with FLEXnet Licensing or may appear in a format customized by the application. Format 1 (short): FLEXlm error text (-lm_errno, minor_num[:sys_errno]) [sys_error_text] The system error information may be missing. Example: Can't connect to license server system (-15,12:61) Connection refused Format 2 (long-version 6.0+): FLEXlm error textFLEXlm error license error 26 explanation[Optional Supporting information]FLEXlm error: -lm_errno, minor_num. [System Error: sys_errno] ["system_error_text"] Example: Cannot connect to license server systemThe server (lmgrd) has not been started yet, orthe wrong port@host or license file is being used, or theport or hostname in the license file has been changed.Feature: f1Server name: localhostLicense path: @localhost:license.dat:./*.licFLEXlm error: -15,12. System Error: 61 "Connection refused" Error Code Descriptions The following table lists the most common errors produced by FLEXenabled products. Table E-1: FLEXnet Licensing Error Codes Error Code Description -1 Cannot find license file. -2 Invalid license file syntax. -3 No license server system for this feature. -4 Licensed number of users already reached. -5 No such feature exists. -6 No TCP/IP port number in license file and FLEXnet Licensing service does not exist. (pre-v6 only) -7 No socket connection to license server manager service. -8 Invalid (inconsistent) license key or signature. The license key/signature and data for the feature do not match. This usually happens when a license file has been altered. -9 Invalid host. The hostid of this system does not match the hostid specified in the license file. -10 Feature has expired. -11 Invalid date format in license file. -12
Start->CMD->ping "hostname" or "IP-addresse" 2)Is there any firewall running that blocks the flexnet port? If yes disable it or open the port 3)Open the license file and check if the hostname is correct check: start->cmd->hostname and enter the shown hostname into the license file you'll find the file here: flexnet\licensing\license.dat 4)Is the MAC Addresse in the license file the same as the MAC that the ptc setup asks you for? If not you'll probably have to change the rank of your network cards. You can do that here: start->regedit-> HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion \NetworkCards Simply change the rank of the network card that has got the asked MAC to NR1 and restart the Computer. 5)If the problem occurs after a system/server crash check if any network card is deactivated! 6)After a Creo Pro Engineer crash it might happen that the license is still in use: Start->cmd->services.msc and restart the service flexlm server for ptc or flexnet server for ptc 7)If don't have permission to access the license server you can release a license from your client too. 1) start->cmd->ptcflush 2) the order will ask for the following syntax: ptcflush [feature] [license server] [port][handle] you can explore the syntax easily by typing ptcstatus Was this Post helpful for you? With engineered regards Posted by proeconsult at 6:15 AM Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest Newer Post Older Post Home Popular Posts 7 Reasons why this happens: License not found /license error/ license request failed/ Pro Engineer and its cure. 1)client has connection to the license server? Ping the server Start->CMD->ping "hostname" or "IP-addresse" 2)Is there any fi... How to disable tolerances in Creo/Pro Engineer If you don't want the tolerances to appear during your work with Creo/Pro Engineer do the following things: 1) In drawing mode: righ... How to insert a jpeg/bmp/tif/gif to a ProEngineer Drawing? WF5 Step by step guide: Go to Layout->insert object->new->paintbrush picture Just copy the picture you wish into paintbrush, s... Subscribe my Blog Follow by Email Posts ▼ 2011 (10) ► December (2) ▼ May (3) How to insert a jpeg/bmp/tif/gif to a ProEngineer ... 7 Reasons why this happens: License not found /lic... How to convert from mm to inch in ProEngineer? ► April (5) Pages home about me Simple template. Powered by Blogger.