the presence of firewall or anti-virus software on the local computer or network connection. Either can block the ports needed to make a successful FTP connection to the remote server. For a regular FTP session, either disable the firewall or anti-virus software
Socket Error 10061 Connection Refused
or configure them to allow CuteFTP to establish an FTP session over ports 20 and 21. 10060 socket error Consult the documentation or help file for your specific firewall or antivirus software product for instructions. Usually the manufacturer of the device or software
What Is A Socket Error
will also have specific instructions available on their Web site. If you continue to receive the same error after insuring ports 20 and 21 are open, contact the administrator of the site you are trying to connect to. For more how to fix socket error 10060 error code information, refer to Knowledge Base article 10140 at http://kb.globalscape.com. WSAETIMEDOUT (10060) 10060 is a connection-timeout error that usually appears when the client does not receive a response from the server for a specific command. This error often occurs when you try to connect in PASV mode to a server that prefers PORT for data connections. If you see an error log similar to the one below, in the Site Properties of the problem site, click the Type tab, then socket error 10060 connection timed out change the Data Connection Type to Use PORT. COMMAND:> PASV 227 Entering Passive Mode (xxx,xx,xxx,xx,x,xxx). COMMAND:> LIST STATUS:> Connecting ftp data socket xxx.xx.xxx.xx:xxxx... ERROR:> Can't connect to remote server. Socket error = #10060. ERROR:> Failed to establish data socket. If you still receive a 10060 error, the server may be trying to send a listing for a very large directory (with many thousands of files) causing the client to time-out while waiting. Try increasing the time-out value in the Global Options dialog box (Tools > Global Options > Transfer > Reconnect and resume in [ n ] seconds if nothing received ) to a higher value, such as 45 or 60 seconds. The connection fails due to an error or timeout. Verify that the destination IP address is correct. Increase the connection timeout threshold under Global Settings > Connection. Switch to the opposite data connection type (PASV or PORT) under Site Settings > Type tab. Verify that the problem is not local by trying to connect to an alternate server. If a server name was used, verify it resolves to the correct address. If using a local server table for server name resolution, check to see that it doesn't resolve to an obsolete address. Try pinging the address. (See Troubleshooting Tips for details.) If you are using a router, verify the router is up and running (check by pinging it and then ping an address outside of the router
number which the command needs to convey back to the 4D database. If a command is successful, a zero will be returned. The source of an error number
Winsock Error 10061
can usually be determined by the range of values which the error falls within. The error code 10060 socket connection failed following table provides an index to the most likely creator of an error in any given range: Error NumberGenerated by Error
Socket Error 10061 Connection Refused Windows 7
< ZeroOperating System Error or WinSock network layer ZeroNo Error Error 1 -> 61BSD network layer Error >= 100004D Internet Commands Error 4D Internet Commands Error Codes If an error occurs during any operation, a numeric http://help.globalscape.com/help/cuteftp8/Socket_errors_10060_10061_10064_10065.htm value from the following table will be returned: 10000user cancelled a dialog or progress. 10001unimplemented Internet command. 10002invalid array type. 10003no more (TCP,SMTP,POP3, etc. ) references available. 10004invalid reference. 10005need a "Host" for use in the "SMTP_Send" command. 10006need a "From" for use in the "SMTP_Send" command. 10007need a recipient for use in the "SMTP_Send" command. 10008already logged in. 10009error trying to make a POP3 connection. 10010error with POP3 USER. 10011error with POP3 http://www.4d.com/docs/CMU/CMU88906.HTM PASS. 10012error with POP3 QUIT. 10013error with POP3 STAT. 10014error with POP3 LIST. 10015error with POP3 UIDL. 10016error with POP3 DELE. 10017error with POP3 RSET. 10018invalid message number. 10019invalid character offset. 10020invalid character length. 10021error with POP3 RETR. 10022field was not found in mail Header. 10023no attachments found. 10024error in processing BinHex. 10025BinHex checksum error. 10026Internet commands unavailable. Probably because MacTCP is not installed 10027Connection no longer exists 10028Exceeded 32k limit 10029Error with POP3 NOOP 10030POP3 session was closed by the server 10031Error with POP3 APOP 10032Unknown or invalid response. 10033SMTP 421 - Service not available, closing transmission channel. 10034SMTP 450 - Requested mail action not taken: mailbox unavailable. 10035SMTP 451 - Requested action aborted: local error in processing. 10036SMTP 452 - Requested action not taken: insufficient system storage. 10037SMTP 500 - Syntax error, command unrecognized. 10038SMTP 501 - Syntax error in parameters or arguments. 10039SMTP 502 - Command not implemented. 10040SMTP 503 - Bad sequence of commands. 10041SMTP 504 - Command parameter not implemented. 10042SMTP 550 - Requested action not taken: mailbox unavailable. 10043SMTP 551 - User not local; please try
10064 Unable to contact host error (#ERRM1006401) Last updated: Applies to: In industries: Of http://my.storman.com/support/knowledgebase/errors/10064.php versions: Article notes: Special contents: 20120912 (Andy) Pro, MultiUser, MultiSite, MultiView 7.X (and higher) n/a n/a What is a "10064 Unable to contact host" error? This particular error generally appears when trying to send email from within StorMan and is caused by a 3rd-party application blocking StorMan traffic. The issue socket error may be caused by a virus scanner, port blocker or incorrect firewall configuration. On occasions, our Technical Support Agents have found a program called winagent.exe running on affected computers. This program is a remote spying application and you (or your I.T. provider) will need to disable or remove this program - or add an exception for StorMan socket error 10061 - to correct the issue. For more details, see our list of programs that interfere with StorMan (#HWSPIS01). Related articles: Article tags: How did we do? This article has no related articles at this time... 10064 error, unable to contact host error Did we miss a tag? Tags improve search results. If you think this article needs more tags to help index & identify it, please suggest some using the form to the right... If this article requires an update or needs more information, please contact support@storman.com.Thank you for your assistance! Latest News & Blogs Please wait while the satellite moves into position... {title} posted by {author} on {date} Key Links Home About myStorMan Contact Control Panel Knowledgebase Legal News Blogs Online Store Storman Training Contact Us View our full contact details, including postal addresses, map locations and fax numbers. Copyright © 1992 - 2016 StorMan Software|View our privacy policy or link to us|Find us on: Google+ & Twitter