Error 500 System Notboundexception
startup; systemnotbound; page not found Technote (troubleshooting) Problem(Abstract) HTTP error - 500:system#not bound exception is error 500 psdi util mxsystemexception bmxaa4188e received when trying to bring up the login page Cause The maximo internal server error Maximo application has not started Diagnosing the problem Review the Maximo and application server logs for Maximo the configdb and restorefrombackup actions must complete before the maximo server can start startup error Resolving the problem The WebSphere or WebLogic console show that the Maximo Server is running and also the Maximo application is running. From the application bmxaa6454e server level everything starts fine. The issue is the Maximo application has not started/initialized successfully. If the Maximo root logger logging level is at INFO or above (INFO is the default) the Maximo startup will be logged. WebSphere Open the systemout.log file for the Maximo Application Server. For example ibm\websphere\appserver\profiles\ctpappsrv01\logs\mxserver\systemout.log Search for the text 'Maximo is ready for client connections'. This means the Maximo application has started successfully and you should be able to connect and login. If that text is not in the log, search for the text ' Maximo failed to start'. If Maximo failed to start there will probably also be an error message. That error is the root cause of the Maximo startup. Address the error and restart the Maximo Application Server. WebLogic If running from a command prompt, the startup will be in that command prompt window. If running from a service, open the maximo.log file for the Maximo Application Server. If the maximo.log is not configured to be created, start the Maximo Server from a command prompt so you can see the startup logging. Search for the text 'Maximo is ready for client connections'. This means the Maximo application has started successfully and you should be able to connect and login. If that text is not in the log, search for the text ' Maximo fail
completed with errors; system#notboundexception; MXServer must be up to run AddUser Technote (troubleshooting) Problem(Abstract) Unable to run AddUser.bat successfully to create bulk users. Symptom BMXAA68201 - Reading the properties file maximo.properties. MXServer must be up to run AddUser Wed May 11 14:56:54 EST 2011 system#notboundexception Wed May 11 14:56:54 EST 2011 BMXAA6819I - AddUser completed with errors. Wed May 11 14:56:54 EST 2011 Cause The cause of this error has to do with the MXServer not running while using this utility - as stated on the error message above - MXServer 'must' be up to run AddUser.bat Diagnosing the problem Simple test to http://www-01.ibm.com/support/docview.wss?uid=swg21433828 confirm why this error occurred - stop MXServer and run AddUser.bat - the error system#notboundexception shows up on the command line - start up MXServer and run this test and it should finish successfully. Resolving the problem Check and confirm that MXServer is up and running by logging into Maximo - if not - be sure to start it and confirm you are able to login - once confirm - http://www-01.ibm.com/support/docview.wss?uid=swg21499227 try running this utility again - this should work. Note: best practice is to run this utility from a command prompt to be sure it finished successfully and/or if it errors out - you will be able to observe what is required to correct the problem. Another cause of this error has to do with the MXserver being hardcoded prior to Maximo 7.5 - APAR IV00386 addressed this issue. Reference link to this APAR added below for your review. Related information AddUser utility is hardcoded for MXServer in the mxe.na Cross reference information Segment Product Component Platform Version Edition Systems and Asset Management Tivoli Change and Configuration Management Database Windows 6.2.7, 7.1, 7.1.1, 7.1.2, 7.2, 7.2.2, 7.5 Edition Independent Systems and Asset Management Tivoli Asset Management for IT Windows Version Independent Edition Independent Systems and Asset Management Tivoli Service Request Manager Windows 2003 server, Windows 2008 server 6.2.7, 7.1, 7.1.2, 7.2, 7.2.1, 7.5 Edition Independent Document information More support for: Maximo Asset Management Archive Application Software version: Version Independent Operating system(s): Platform Independent Software edition: Edition Independent Reference #: 1499227 Modified date: 2016-04-06 Site availability Site assistance Contact and feedback Need support? Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility
URL durch den Client (z.B. Ihr Webbrowser oder unser CheckUpDown-Roboter) zu erfüllen. Dies ist ein 'Catch-All (Sammel)'-Fehler, der vom Webserver erzeugt wird. Es ist grundlegend etwas falsch gelaufen, aber der http://www.checkupdown.com/status/E500.html Server kann nicht genauer zu der Fehlerbedingung in seiner Antwort auf den Client sein. Zusätzlich zu dem an den Client zurückgegebenen 500-Fehler, sollte der Webserver ein internes Fehlerprotokoll erzeugen, das mehr Einzelheiten zu dem was falsch gelaufen ist enthält. Es ist Aufgabe der Betreiber der Webserversite, diese Protokolle zu lokalisieren und analysieren. Beheben von 500-Fehlern - allgemein Diese Fehler können nur durch error 500 Reparaturen an der Webserver-Software behoben werden. Es es kein Problem auf der Client-Seite. Es ist Aufgabe der Betreiber des Webserversite, diese Protokolle zu lokalisieren und analysieren, die genauere Informationen zu dem Fehler geben sollten. Beheben von 500-Fehlern - CheckUpDown Wir überwachen Ihre Site auf Fehler wie 500. Bitte wenden Sie sich direkt (am besten per E-Mail) an uns, wenn Sie bei Ihrem CheckUpDown-Account error 500 system auf 500-Fehler stoßen. Wir müssen dann mit Ihrem ISP und dem Hersteller der Webserver-Software in Verbindung treten, so dass sie den genauen Grund für den Fehler nachverfolgen können. Das Beheben des Fehlers kann eine Aufzeichnung der Programmlogik für Ihre Webserver-Software erfordern, was einige Zeit dauern kann. 500-Fehler im HTTP-Ablauf Jeder Client (z.B. Ihr Webbrowser oder unser CheckUpDown-Roboter) durchläuft den folgenden Ablauf, wenn er mit dem Webserver kommuniziert: Eine IP-Adresse aus dem IP-Namen der Site zuweisen (die URL der Site ohne das vorangestellte 'http://'). Dieses Nachschlagen (Umwandlung des IP-Namens in die IP-Adresse) wird durch Domain-Namen-Server (DNS) geleistet. Öffnen einer IP-Socket-Verbindung zu dieser IP-Adresse. Schreiben eines HTTP-Datenstroms über diesen Socket. Rückempfangen eines HTTP-Datenstroms vom Webserver als Antwort. Dieser Datenstrom enthält Statuscodes, deren Werte durch das HTTP-Protokoll bestimmt werden. Parsen dieses Datenstroms auf Statuscodes und andere nützliche Informationen. Dieser Fehler tritt im obigen letzten Schritt auf, wenn der Client einen HTTP-Statuscode empfängt, den er als '500' erkennt. Unser Unternehmen betreibt auch die folgenden Websites: Ein einfacher Leitfaden zu Software-Escrow. www.softwareescrowguide.com Unser wirklich einfacher Leitfaden zum Web-Hosting (so bekommen Sie Ihre Website und E-Mail-Adresse mit Ihrem eigenen Domain-Namen ins Internet). www.simplewebhosting