Ftp Error Code 10054
Contents |
» Socket Error 10054 Socket Error 10054 Last Year GlobalSCAPE Support 1 CuteFTP for Windows THE INFORMATION IN THIS ARTICLE APPLIES TO: CuteFTP® Home (All Versions) CuteFTP Pro® (All Versions) SYMPTOMS During an FTP session, the following error is encountered: ERROR:> Can't read from control socket. windows socket error 10054 Socket error = #10054. CAUSE & RESOLUTION A socket error 10054 may be the
Socket Error 10054 Connection Reset By Peer
result of the remote server or some other piece of network equipment forcibly closing or resetting the connection. In some other situations socket error 10054 ftp a change to the default CuteFTP connection settings may be needed for connections to this particular remote FTP server. The most common cause for a socket error 10054 is the use of an invalid FTP socket error attempting to send 10054 host address. Double-check to make sure that you are using the correct FTP host address. Before making any changes to the default configuration for CuteFTP, wait and retry your connection later. A socket error 10054 can also be caused by any of the following reasons: The remote server was stopped or restarted. The remote network interface is disabled for some reason. There are too many users logged on to the server. Your
Error 10054 Sql Server
account on the remote server is restricted for some reason. If this error started happening after a recent upgrade to your Web browser, (for example, after upgrading to Internet Explorer 7.0) please browse to KB Article ID 10294 for instructions. If you are satisfied that the remote server or user account is not at fault, and you encountered this error either when first establishing the connection or when starting a file transfer, then it may be necessary to change the data connection type. CuteFTP uses passive (PASV) mode by default but for this remote server you may need to use active (PORT) mode instead. To make the switch from PASV mode to PORT mode in CuteFTP Home, open the Site Manager and click once on the the name of the problem site on the left side of the window. On the Type tab change the Data Connection Type to Use Port. If you are using CuteFTP Professional, in the Site Manager, right-click on the name of the problem site and click Site Properties. On the Type tab, change the Data Connection Type to Use Port. Note: If changing the data connection type has no effect then you should return this setting to the default of Use global settings. In some other situations,
360 games PC games error code 10054 logmein Windows games Windows phone games Entertainment All Entertainment error code 10054 connection reset by server Movies & TV Music Business & Education Business Students & educators
Socket Error 10054 Connection Reset By Peer Delphi
Developers Sale Sale Find a store Gift cards Products Software & services Windows Office Free downloads & security Internet https://kb.globalscape.com/KnowledgebaseArticle10235.aspx Explorer Microsoft Edge Skype OneNote OneDrive Microsoft Health MSN Bing Microsoft Groove Microsoft Movies & TV Devices & Xbox All Microsoft devices Microsoft Surface All Windows PCs & tablets PC accessories Xbox & games Microsoft Lumia All https://support.microsoft.com/en-us/kb/981344 Windows phones Microsoft HoloLens For business Cloud Platform Microsoft Azure Microsoft Dynamics Windows for business Office for business Skype for business Surface for business Enterprise solutions Small business solutions Find a solutions provider Volume Licensing For developers & IT pros Develop Windows apps Microsoft Azure MSDN TechNet Visual Studio For students & educators Office for students OneNote in classroom Shop PCs & tablets perfect for students Microsoft in Education Support Sign in Cart Cart Javascript is disabled Please enable javascript and refresh the page Cookies are disabled Please enable cookies and refresh the page CV: {{ getCv() }} English (United States) Terms of use Privacy & cookies Trademarks © 2016 Microsoft
AutoMate 6, AutoMate 5 Published: 6/23/06 , modified June 23, 2006 IntroductionA socket is defined as one endpoint of a two-way communication link between two programs running on the network. A socket is bound to a port number so that the TCP layer can identify the application that data is destined to be http://www.networkautomation.com/urc/knowledgebase/common-ftp-socket-errors/02899795-9874-19FA-89D9FA88304286FA/ sent.Normally an FTP server runs on a specific machine and has a socket that https://en.wikipedia.org/wiki/List_of_FTP_server_return_codes is set to a specific port number. The server mainly waits and listens to the socket for a client to make a connection request. The client makes a connection request by trying to meet with the server on the server's machine and port. If everything goes well, the server accepts the connection. Upon acceptance, the server gets a new socket error socket bound to the same port. It needs a new socket so that it can continue to listen to the original socket for connection requests from other clients while tending to the needs of the currently connected client. On the client side, if the connection is accepted, a socket is successfully created and the client can use the socket to communicate with the server. The client and server can now communicate by writing to socket error 10054 or reading from their sockets. A socket error can occur if one or more of the above conditions are not met or something is blocking communication between the client and server (e.g. firewall, anti-virus). Additionally, a client connection can already be established with a server when a socket error occurs such as in cases when the network connection goes down or the host that the client connected to suddenly crashed and/or rebooted. Common FTP Socket Error Codes 11001 - Host not found. Check that the hostname or IP address has been entered correctly. 11004 - Valid name, no data record of requested type.This error generally indicates that the specified FTP server name is incorrect or not specified. Try entering the hostname or IP address, not a URL (e.g. if ftp://server.domain.com/ is entered, then change it to server.domain.com). Another possibility is that connection is blocked by a firewall. Try temporarily turning off the Windows firewall or any other software firewall you are running.10061 - Connection refused. The hostname is correct, but the FTP server is not listening on the port, there is no FTP server running, or a firewall is blocking the connection.10093 - Connection failed. This can happen when the network connection goes down, e.g. the FTP server is no longer connected to the network.10039 - Destination address required. Ther
good, bad or incomplete: Range Purpose 1xx Positive Preliminary reply The requested action is being initiated; expect another reply before proceeding with a new command. (The user-process sending another command before the completion reply would be in violation of protocol; but server-FTP processes should queue any commands that arrive while a preceding command is in progress.) This type of reply can be used to indicate that the command was accepted and the user-process may now pay attention to the data connections, for implementations where simultaneous monitoring is difficult. The server-FTP process may send at most, one 1xx reply per command. 2xx Positive Completion reply The requested action has been successfully completed. A new request may be initiated. 3xx Positive Intermediate reply The command has been accepted, but the requested action is being held in abeyance, pending receipt of further information. The user should send another command specifying this information. This reply is used in command sequence groups. 4xx Transient Negative Completion reply The command was not accepted and the requested action did not take place, but the error condition is temporary and the action may be requested again. The user should return to the beginning of the command sequence, if any. It is difficult to assign a meaning to "transient", particularly when two distinct sites (Server- and User-processes) have to agree on the interpretation. Each reply in the 4xx category might have a slightly different time value, but the intent is that the user-process is encouraged to try again. A rule of thumb in determining if a reply fits into the 4xx or the 5xx (Permanent Negative) category is that replies are 4xx if the commands can be repeated without any change in command form or in properties of the User or Server (e.g., the command is spelled the same with the same arguments used; the user does not change his file access or user name; the server does not put up a new implementation.) 5xx Permanent Negative Completion reply The command was not accepted and the requested action did not take place. The User-process is discouraged from repeating the exact request (in the same sequence). Even some "permanent" error conditions can be corrected, so the human user may want to direct his User-process to reinitiate the command sequence by direct action at some point in the future (e.g., after the spelling has been changed, or the