Error 87 Parameter Incorrect Iis
Contents |
Start here for a quick overview of the site Help Center Detailed answers to any questions you might error 87 the parameter is incorrect delayed start have Meta Discuss the workings and policies of this site About Us
Error 87 The Parameter Is Incorrect Windows 7
Learn more about Stack Overflow the company Business Learn more about hiring developers or posting ads with error 87 the parameter is incorrect robocopy us Server Fault Questions Tags Users Badges Unanswered Ask Question _ Server Fault is a question and answer site for system and network administrators. Join them; it only
Error 87 The Parameter Is Incorrect Windows 8
takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the top IIS Admin Service won't start - error 87: The parameter is incorrect up vote 1 down vote favorite Windows Server 2012. IIS admin service stopped - when try error 87 the parameter is incorrect windows server 2008 to start from Services.msc get the following error. Event log show two errors event 1000 and event 7023 (see below for details). Any suggestions would be greatly appreciated! World wide publishing service (w3svc) is running fine. "Windows could not start the IIS Admin Service on local computer. Error 87: The parameter is incorrect". Tried below without any luck: Rebooting server IISRESETs net start iisadmin PS> Start-Service iisadmin produces below error PS C:\Windows\system32> Start-Service iisadmin Start-Service : Failed to start service 'IIS Admin Service (iisadmin)'. At line:1 char:1 + Start-Service iisadmin + ~~~~~~~~~~~~~~~~~~~~~~ + CategoryInfo : OpenError: (System.ServiceProcess.ServiceController:ServiceController) [Start-Service], ServiceCommandException + FullyQualifiedErrorId : StartServiceFailed,Microsoft.PowerShell.Commands.StartServiceCommand Windows Event Viewer Errors: Log Name: Application Source: Application Error Date: 7/25/2015 5:38:51 PM Event ID: 1000 Task Category: (100) Level: Error Keywords: Classic User: N/A Computer: Web03.magna.global Description: Faulting application name: mmc.exe, version: 6.2.9200.16496, time stamp: 0x50ece2e8 Faulting module name: DUser.dll, version: 6.2.9200.16518, time stamp: 0x510ca23f Exception code: 0xc000041d Fault offset: 0x000000000000166d Faulting process id: 0xbfc Faulting application start time: 0x01d0c714b8ffc77f Faulting application
platform and distributed applications Fail to start W3SVC: The parameter is incorrect ★★★★★★★★★★★★★★★
Error 87 The Parameter Is Incorrect Starting Service
APGC DSI TeamNovember 26, 20093 0 0 0 Symptom
Windows Api Error 87 The Parameter Is Incorrect
When start World Wide Web Publishing dism error 87 the parameter is incorrect Service service, the following Service error message popup Could not start the World Wide Web Publishing Service service on Local Computer. Error 87: http://serverfault.com/questions/708525/iis-admin-service-wont-start-error-87-the-parameter-is-incorrect The parameter is incorrect. In the system log, Event 7000 was logged: Event Type: Error Event Source: Service Control Manager Event Category: None Event ID: 7000 Date: 11/26/2009 Time: 3:49:37 PM User: N/A Computer: XXXXX Description: The World Wide Web Publishing Service service failed to start due https://blogs.msdn.microsoft.com/asiatech/2009/11/26/fail-to-start-w3svc-the-parameter-is-incorrect/ to the following error: The parameter is incorrect. Troubleshooting Run net start command, still get the same issue: net start w3svc Run the Process Monitor log, we found there is no service command to start executing the World Wide Web Publishing Service (i.e. C:\WINDOWS\System32\svchost.exe -k iissvcs) Events should be similar with below when starting W3SVC on good IIS box. 12:26:26.6020853 PM 1040 services.exe 400 Process Create C:\WINDOWS\System32\svchost.exe SUCCESS PID: 10692, Command line: C:\WINDOWS\System32\svchost.exe -k iissvcs 12:26:26.6020970 PM 1041 svchost.exe 10692 Process Start SUCCESS Parent PID: 400 12:26:26.6021233 PM 1042 svchost.exe 10692 Thread Create SUCCESS Thread ID: 11680 Hence, the issue can be caused by register key since the system service needs to get related information from service register value first. Root Cause We found extra Environment value under the HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W3SVC\, as below: Windows Registry
360 games PC games https://support.microsoft.com/en-us/kb/242211 Windows games Windows phone games Entertainment All Entertainment Movies & TV Music Business & Education Business Students & educators https://community.flexerasoftware.com/showthread.php?153893-Starting-a-IIS-website-and-quot-the-parameter-is-incorrect-quot Developers Sale Sale Find a store Gift cards Products Software & services Windows Office Free downloads & security Internet error 87 Explorer Microsoft Edge Skype OneNote OneDrive Microsoft Health MSN Bing Microsoft Groove Microsoft Movies & TV Devices & Xbox All Microsoft devices Microsoft Surface All Windows PCs & tablets PC accessories Xbox & games Microsoft Lumia All error 87 the Windows phones Microsoft HoloLens For business Cloud Platform Microsoft Azure Microsoft Dynamics Windows for business Office for business Skype for business Surface for business Enterprise solutions Small business solutions Find a solutions provider Volume Licensing For developers & IT pros Develop Windows apps Microsoft Azure MSDN TechNet Visual Studio For students & educators Office for students OneNote in classroom Shop PCs & tablets perfect for students Microsoft in Education Support Sign in Cart Cart Javascript is disabled Please enable javascript and refresh the page Cookies are disabled Please enable cookies and refresh the page CV: {{ getCv() }} English (United States) Terms of use Privacy & cookies Trademarks © 2016 Microsoft
InstallShield InstallShield 11 Express Starting a IIS-website and "the parameter is incorrect" If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. Page 1 of 2 12 Last Jump to page: Results 1 to 5 of 6 Thread: Starting a IIS-website and "the parameter is incorrect" Thread Tools Show Printable Version Subscribe to this Thread… Display Linear Mode Switch to Hybrid Mode Switch to Threaded Mode 11-11-2005,09:26 AM #1 EspenS View Profile View Forum Posts New User (0 Posts) Join Date Nov 2005 Posts 3 Starting a IIS-website and "the parameter is incorrect" I'm using Installshield 11 Express, and have created a setup-project which installs a new website (on port 8030), with one virtual directory. The installation seems to run nicely, but when I try to start the newly installed website, I get the error "The parameter is incorrect". Google-searches on this issue reveals that this issue might be related to the associated application pool, but the default application pool is associated with the website, and even creating a new application pool and associating this doesn't help. If I create the website manually, with the same settings, it works fine. Hence, it seems as if the installshield-setup creates a corrupted website under IIS. I'd really apprechiate some suggestions on this! EspenS Reply With Quote 11-11-2005,10:54 AM #2 EspenS View Profile View Forum Posts New User (0 Posts) Join Date Nov 2005 Posts 3 Update on the last posting: I discovered that, after all, the problem is the appPoolId after all. It turns out, when I created an xml config file from the web site, that the parameter "AppPoolId" is empty after all. In the properties-window in iis manager, the web site is associated with the default app pool. But, as you can see from the snippet below, the parameter is not really set. InstallShield developers, this must be due to a InstallShield bug! Is there a software patch which corrects this problem, or is there at least a workaround?? EspenS Snippet from the xml config file: