Correctable Memory Error Logging Limit Reached On Dimm 3
Contents |
limit reached Join Sign in PowerEdge R720 memory error limit reached Servers Information and ideas on Dell PowerEdge rack, tower and blade server solutions. Get
Correctable Ecc Memory Error Logging Limit Reached
this RSS feed Home Forums Server Media Gallery 8 Replies 3 Subscribers Postedover vmware memory correctable ecc logging limit reached 2 years ago PowerEdge R720 memory error limit reached This question has been answered by Dell-Chris H Posted by memory device correctable ecc logging limit reached weadonj on 7 Apr 2014 8:07 I have a PowerEdge R720 running XenServer 6.2. We have received this error for the second time in the last 3 weeks: "MEM0005 Persistent correctable memory
Assert + Memory Correctable Ecc Logging Limit Reached
error limit reached for DIMM1,DIMM2,DIMM3,DIMM4,DIMM5,DIMM6,DIMM7,DIMM8 reseat memory". Two weeks ago when we got this error the first time, We powered off the server and made sure all the memory was properly seated (it was). We powered the server back on and the error was gone. Since this is a production box requiring HA, we did not take a bunch of time to run
Correctable Memory Error Rate Exceeded For Dimm
extra diagnostic tests. The error came back this morning. Does anyone have an idea of how we can resolve this issue? Thanks Like 0 Reply You have posted to a forum that requires a moderator to approve posts before they are publicly available. Verified Answer Posted by Dell-Chris H on 7 Apr 2014 11:50 Verified Answer Verified by weadonj WeadonJ, The error you are receiving is stating that the memory is operational, but is at an early indicator of a possible future uncorrectable error. My suggestion would be to reseat the dimms, then run diagnostics on them to see if there is anything that shows up. I would suggest booting to this diagnostic for the memory test. -http://www.dell.com/support/home/us/en/555/Drivers/DriversDetails?driverId=TRWYD&fileId=3332974416&osCode=CXS03&productCode=poweredge-r720&languageCode=EN&categoryId=DI Also, what revision is the BIOS and ESM/Drac sitting at? Are either up to date? Let me know what you find out. Chris Hawk Dell | Social Outreach Services - Enterprise Get Support on Twitter @DellCaresPro Download the Dell Quick Resource Locator app today to access PowerEdge support content on your mobile device! (iOS,Android,Windows) Like 0 Reply You have posted to a forum that requires a moderator to approve posts be
are available on the IBM Web site at http://www.ibm.com/systems/support/supportsite.wss/docdisplay?lndocid=MIGR-5079338&brandind=5000008. Follow the suggested actions in the order in which they are listed correctable memory error rate exceeded for dimm b2 in the Action column until the problem is solved. See Parts
Correctable Memory Error Rate Exceeded For Dimm Dell
listing to determine which components are CRUs and which components are FRUs. If an action step is correctable memory error rate exceeded for dimm a2 preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Error Code Event ID Type Error Message Action 0x80010200 80010202-1002xxxx Error Expansion http://en.community.dell.com/support-forums/servers/f/956/t/19577325 Module 1 (BPE3 12V Sense) voltage under critical threshold. Reading: X, Threshold: Y If the under voltage problem is occurring on all blade servers, look for other events in the IMM event log related to power and resolve those events (see Error logs). View the event log provided by the advanced management module for your BladeCenter unit https://publib.boulder.ibm.com/infocenter/bladectr/documentation/topic/com.ibm.bladecenter.hs22.doc/dw1iv_r_IMM_error_messages.html and resolve any power related errors that might be displayed. If other modules or blades are logging the same issue then check the system power supply, otherwise replace the Blade PCI Express I/O expansion unit. See Removing an optional expansion unit and Installing an optional expansion unit. 0x80010200 80010202-1002xxxx Error Expansion Module 1 (BPE3 12VSB Sense) voltage under critical threshold. Reading: X, Threshold: Y If the under voltage problem is occurring on all blade servers, look for other events in the log related to power and resolve those events (see Error logs). View the event log provided by the advanced management module for your BladeCenter unit and resolve any power related errors that might be displayed. If other modules or blades are logging the same issue; then, check the power supply for the BladeCenter unit. If the base blade is not logging a power issue; then, replace the Blade PCI Express I/O expansion unit. See Removing an optional expansion unit and Installing an optional expansion unit. 0x80010200 80010202-1002xxxx Err