Group 1 Dimms Bus Uncorrectable Error
Contents |
Error Code = IMM events displayed by AMM (for example, Service Advisor, AMM web interface) Event ID = IMM events displayed by DSA diagnostic program (for a uncorrectable bus error has occurred on system example, in the Chassis Event Log section) Follow the suggested actions in system board (planar vbat) voltage under critical threshold the order in which they are listed in the Action column until the problem is solved. See Parts system board, voltage (planar fault) critical listing to determine which components are consumable, structural, or CRU parts. If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained technician. problem determination and service guide hs22 Error Code Event ID Type Error Message Action 0x80010000 80010002-0701ffff Warning System board (CMOS battery) voltage under warning threshold. with chassis Reading: X, Threshold: Y If the machine has been recently installed, moved, or serviced, ensure the system battery is properly seated, and the system battery polarity is correct. Replace the system battery (see Removing the battery and Installing the battery).
Fault In Slot All Pci Error On System
0x80010200 80010202-0701ffff Error System board (CMOS battery) voltage under critical threshold. Reading: X, Threshold: Y Remove all expansion cards from the blade server (see Removing an I/O expansion card). Remove all storage drives from the blade server (see Removing a hot-swap storage drive). If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly). 0x80010200 80010202-0701ffff Error System board (SysBrd 5V) voltage under critical threshold. with chassis Reading: X, Threshold: Y Remove all expansion cards from the blade server (see Removing an I/O expansion card). Remove all storage drives from the blade server (see Removing a hot-swap storage drive). If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly). 0x80010200 80010202-0701ffff Error System board (SysBrd 12V) voltage under critical threshold. with chassis Reading: X, Threshold: Y If the under voltage problem is occurring on all blade servers, look for other events in the log related to power and resolve those events (see Event logs). View the event log provided by the advanced management mo
the blade server and posts events in the IMM event log. In addition, most events are also sent to the advanced management module event log. The following table lists
Sensor "planar Fault" Has Transitioned To Critical From A Less Severe State
IMM error messages that are displayed in the advanced management module event scrub failure for memory device log and suggested actions to correct the detected problems. These events, in a slightly different format, are also displayed 816f01251001ffff in the IMM event log.Note: An updated list of IMM error messages and corrective actions are available on the IBM® website at http://www.ibm.com/systems/support/supportsite.wss/docdisplay?lndocid=MIGR-5079339&brandind=5000008. Follow the suggested actions in the order in which https://publib.boulder.ibm.com/infocenter/bladectr/documentation/topic/com.ibm.bladecenter.hs23.doc/IMM_error_messages.html they are listed in the Action column until the problem is solved. See Parts listing - BladeCenter HX5 to determine which components are CRUs and which components are FRUs. If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Type Error Message Action Error Code: 0x80010200 Note: Multiple events can be https://publib.boulder.ibm.com/infocenter/bladectr/documentation/topic/com.ibm.bladecenter.hx5.doc/dw1it_r_IMM_error_messages.html displayed for this error code. Be sure to read the message text to determine the appropriate recovery actions. Error System board (Planar 12V) voltage under critical threshold. Reading: X, Threshold: Y If the under voltage problem is occurring on all blade servers, look for other events in the log related to power and resolve those events (see Event logs). View the event log provided by the advanced management module for your BladeCenter® chassis and resolve any power related errors that might be displayed. If other modules or blade servers are logging the same issue, check the power supply for the BladeCenter chassis. (Trained service technician only) Replace the system-board assembly (see Removing the system-board assembly - BladeCenter HX5 and Installing the system-board assembly - BladeCenter HX5). Error System board (Planar 5V) voltage under critical threshold. Reading: X, Threshold: Y Remove all expansion cards from the blade server (see Removing an I/O expansion card). Remove all storage drives from the blade server (see Removing a solid state drive). (Trained service technician only) Replace the system-board assembly (see Removing the system-board assembly - BladeCenter HX5 and Installing the system-boa
Error Code = IMM events displayed by AMM (for example, Service Advisor, AMM web interface) Event ID = IMM events displayed by DSA diagnostic program (for example, in the https://publib.boulder.ibm.com/infocenter/bladectr/documentation/topic/com.ibm.bladecenter.hs23e.doc/IMM_error_messages.html Chassis Event Log section) Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. See Parts listing to determine which components https://community.spiceworks.com/topic/619346-vmware-esxi-5-5-cluster-hosts-keep-crashing are consumable, structural, or CRU parts. If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained technician. Error Code Event ID Type Error on system Message Action 0x80010200 80010202-0701ffff Error System board (SysBrd 3.3V) voltage (lower critical) has asserted. Remove all expansion cards from the blade server (see Removing an I/O expansion card). Remove all storage drives from the blade server (see Removing a hot-swap storage drive). If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly). 0x80010200 80010202-0701ffff Error System group 1 dimms board (SysBrd 5V) voltage (lower critical) has asserted. Remove all expansion cards from the blade server (see Removing an I/O expansion card). Remove all storage drives from the blade server (see Removing a hot-swap storage drive). If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly). 0x80010200 80010202-0701ffff Error System board (SysBrd 12V) voltage (lower critical) has asserted. If the under voltage problem is occurring on all blade servers, look for other events in the log related to power and resolve those events (see Event logs). View the event log provided by the advanced management module for your BladeCenter unit and resolve any power related errors that might be displayed. If other modules or blades are logging the same issue then check the power supply for the BladeCenter unit. If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly). 0x80010200 80010202-0701ffff Error System board (CMOS battery) voltage (lower critical) has asserted. Replace the system battery (see Removing the battery and Installing the battery). 0x80010700 80010701-1001ffff80010701-1002ffff80010701-1003ffff80010701-1004ffff Warning Expansion Module, (GPU_X TMP) temperature (upper non-crit
XenServer (Opensource) and deploy Virtualized systems, running development environments as well as a few Mission critical systems. New servers We are finally replacing our Server 2003 machines with nice, shiny, new Servers. Server Virtualization Migrated our physical SBS2003 and unified communications server to a virtual environment hosted on EXSI free. TECHNOLOGY IN THIS DISCUSSION VMware 396220 Followers Follow IBM Join the Community! Creating your account only takes a few minutes. Join Now We have a dual esxi 5.5 cluster with 2 IBM x3530 M4's ( 2x Xeon E5-2450 and 96 gig memory) connected to an IBM v3700 DAS. Both hosts are running esxi 5.5.0 2143827. They are in a fail over cluster with one server running all 13 VM's and the other just waiting. They run fine for about a month then start failing with errors "Memory, Group 4 CPUs: Bus Uncorrectable error, Group 1 One of the DIMMS 0: Uncorrectable ECC". IBM has been out to replace the system board, both CPU's, all the memory DIMMS and back plain. Also both servers are running esxi from an IBM commercial graded USB drive connected to hypervisor port on system board which has also been replaced. Since same error messages happen on both servers, I am starting to think it is a vmware issue? Has anyone ran into this kind of issue, and if so what was your fix? Tags: VMware396,220 FollowersFollow IBMReview it: (0) Reply Subscribe RELATED TOPICS: To Cluster or Not to Cluster? Vmware ESXi 5.5 Shutting down VMWare ESXi 5.5 cluster VMware ESXi 5.5 to 5.5 U1   2 Replies Jalapeno OP DominicV Oct 28, 2014 at 6:19 UTC Hi Simple question .. are all your firmware up to date ? I have had similar issues with IBM products and the solution was to update all the firmwares to the latest release. i do mean every firmware ... not just the computer bios. Thanks 0 Anaheim OP Jon5733 Oct 28, 2014 at 6:20 UTC We have upgraded all the firmwares using IBM bomc tool 9.61 0 This discussion has been inactive for over a year. You may get a better answer to your question by starting a new discussion. Text Quote Post |Replace Attachment Add link Te