Early Adopter Program ArcGIS Ideas Esri Support Services ArcGIS Blogs ArcGIS Code Sharing Product Life Cycles Manage Cases Request Case Start Chat Back to results Print Share Is This Content error 1904 module failed to register crystal reports Helpful? Search on GeoNet Submit to ArcGIS Ideas Error: Error 1904: failed error 1904 module failed to register quickbooks to register C:\Program Files\ArcGIS\Bin\xmlsupportui.dll, 3dsymbolsui.dll, or GxRaster.dll Error Message Installing ArcGIS products on a machine with a processor lỗi error 1904 module that supports data execution prevention (DEP), and Windows XP Service Pack 2 (SP2) results in a failed installation. This includes the AMD Athlon 64 Family processors, as well as error 1904 module failed to register windows 7 newer Intel Xeon, Pentium 4, Pentium M or Centrino processors, and Celeron-D processors. The following error message or a similar error message is returned:For ArcGIS 8.x:"Error 1904. Module C:\arcgis\arcexe83\bin\AfuiCust.dll failed to register. HRESULT -2147023898. Contact your support personnel."For ArcGIS 9.x:"Error 1904: failed to register c:\Program Files\ArcGIS\Bin\xmlsupportui.dll" (or 3dsymbolsui.dll, GxRaster.dll). HRESULT -2147023898. Contact your support personnel."Various other DLLs may fail to
How To Fix Error 1904 Module Failed To Register
register during the process. Cause As of Windows XP SP2, Microsoft has enabled data execution prevention (DEP); a feature that is included in newer processor series from AMD and Intel. DEP is a set of hardware and software technologies that perform additional checks on memory to help protect against malicious code exploits. Intel refers to their version of DEP as XD or execution disabling bit. AMD refers to their version of DEP as the NX-bit or No Execute bit. Solution or Workaround Disable DEP in Windows XP SP2 using the steps below: Note: Users with Intel processors may also need to disable the XD or execution disabling bit in their computer's CMOS/BIOS. Since each computer's CMOS is different, reference the computer's manual or contact the manufacturer of the computer for assistance with this step. Warning: The instructions below include making changes to essential parts of your operating system. It is recommended that you backup your operating system and files, including the registry, before proceeding. Consult with a qualified computer systems professional, if necessary. Esri cannot guarantee results f
\ExportModeller.dll failed to register Symptoms: During the installation of
Error 1904 Windows 7
Andica Software, Windows Installer encounters an error: Error 1904.Module error 1904 crystal reports C:\Program Files(x86)\Common Files\Business Objects\2.7\bin\ExportModeller.dll failed to register. HRESULT -2147010895. Contact your support personnel." File error 1904 failed to register installshield name and HRESULT value may be random. Solution: To resolve this issue, download and install the Microsoft C++ Redistributable Package from Microsoft web http://support.esri.com/technical-article/000007439 site using one of the following links. To download Microsoft Visual C++ 2005 SP1 Redistributable Package (x86) - use this update as it seems to work for all Windows versions - click this link http://www.microsoft.com/downloads/details.aspx?familyid=200B2FD9-AE1A-4A14-984D-389C36F85647&displaylang=en If the update from the link above does not work, then you http://www.andica.com/faq_error1904.html can select an update suitable for your version of Windows OS. For Windows 7, Windows 8, Windows 8.1, Windows 10: 32-bit systems: http://www.microsoft.com/en-gb/download/details.aspx?id=5582 64-bit systems: http://www.microsoft.com/en-gb/download/details.aspx?id=2092 For Windows Vista, Windows XP: 32-bit systems: http://www.microsoft.com/download/en/details.aspx?id=5638 64-bit systems: http://www.microsoft.com/download/en/details.aspx?id=18471 Once you have done this, please restart your computer. You may need to reinstall the software. Disclaimer: Information provided here is given without any obligations and we will not accept any claims or liabilities for any damages as a result of you relying on the information given here, if in doubt you must consult a qualified system engineer. Any web links provided to third party website are for your reference, we do not have any control on the validity and content on those websites. We do not take any responsibility for you using or relying on them. Copyright to contents remains
PKI Service Identity Access Manager Shop Online Cyber Security Services Managed Security Services DeepSight Intelligence Incident Response Security Simulation Website Security https://support.symantec.com/en_US/article.TECH89897.html SSL Certificates Complete Website Security Code Signing Certificates Norton Shopping Guarantee Buy SSL Products A-Z Services Services Home Business Critical Services Consulting Services Customer http://www-01.ibm.com/support/docview.wss?uid=swg21279120 Success Services Cyber Security Services Education Services Solutions Solutions Home Topics Encryption Everywhere Internet of Things Next Generation Endpoint Office 365 Industries Automotive Cyber error 1904 Insurance Education Financial Services Global Service Providers Industrial Control Systems Healthcare Retail Government Federal Government State & Local Support Center Technical Support Symantec Connect Buying Programs Upgrades Maintenance & Renewals Training Security Center Security Center Home Blogs ISTR Threats Virus Definitions and Security Updates Removal Tools Partner Find a error 1904 module Partner Become a Partner Login Required Login into Partner Portal Partner Licensing Partner Renewals Partner Training Margin Builder Opportunity Registration Financial Benefits English 中文(简体) 中文(繁體) Česká English Français Deutsch Magyar Italiano 日本語 한국어 Polski Português Pусский Español Site: Symantec Enterprise Small Business Norton United States Search Support Home Support Home MySymantec Licensing Products A-Z SYM16-015 Security Advisory Login Profile Subscriptions Logout Login Forgot Password? Don't have a SymAccount? Create a SymAccount now!' Error Message After Installation: "Error 1904.Module C:\Program Files\Symantec\SMSMSE\\Server\SAVFMSELU.dll failed to register" TECH89897 June 2nd, 2014 http://www.symantec.com/docs/TECH89897 Support / Error Message After Installation: "Error 1904.Module C:\Program Files\Symantec\SMSMSE\
Windows; 2003.06.15; 2003.06.16; 1279120 Technote (troubleshooting) Problem(Abstract) This technote explains why the error Error 1904, Module failed to register. HRESULT 5 might occur when installing IBM Rational ClearCase version 2003.06.00 on Microsoft Windows. Symptom ClearCase installation fails with the following error: "Error 1904.module c:\\Program Files\Rational\ClearCase\bin\ccclientsnode.dll failed to register. HRESULT 5." Note: The .dll may vary from error to error. Cause This may be an operating system issue. A number of various Microsoft Knowledge Base articles include a list of causes including the following: *.dll not being correctly registered on the host system. *The file is not installed correctly. *The file is corrupted. Other programs, including memory-resident and anti-virus programs, are running may be using a version of the file. A dialog box may pop up with the options to click Cancel, Retry, or Ignore. The ClearCase install may also fail. If you click Cancel, a message appears asking whether you want to quit Setup. If you click Retry, the error message reappears. If you click Ignore, Setup continues but may not include all ClearCase components. The Microsoft C++ runtime library (msvcrt.dll) may be corrupted, or exist in multiple locations on the machine. The user performing the installation doesn't have the required administrative privileges to perform the installation. Resolving the problem Resolving Cause 1 above: Empty the Temp Directory. The Temp folder may contain files that are interfering with the installation of ClearCase. To remove these files, use the appropriate method for your operating system. Terminate any memory resident programs and Anti Virus software and attempt a reinstallation of ClearCase. Search the machine for all instances of msvcrt.dll. It should exist in