Error 10048 In Function Bind
Contents |
ease planning, as well. Free PRTG Download >> What is this? This knowledgebase contains questions and answers about PRTG Network Monitor and network error 10048 in function bind address already in use monitoring in general. You are invited to get involved by asking and bind failed with error 10048 answering questions! Learn more Top Tags 5731× prtg 1832× snmp 1462× sensor 932× wmi 621× notifications 463× maps
Ipmsg Bind Error 10048
View all Tags How can I solve an error "10048 (Address already in use.)" in Webserver Stress Tool? Votes:0 Your Vote: Up Down In Webserver Stress Tool, I get an
Redis Bind Error 10048
error message # 10048 Address already in use. Where does it come from and how can I solve this issue? error networking registry webserver-stress-tool Created on Feb 24, 2010 9:05:50 AM by Daniel Zobel [Paessler Support] Last change on Jul 21, 2010 1:54:37 PM by Daniel Zobel [Paessler Support] Permalink 1 Reply Accepted Answer Votes:0 Your Vote: Up Down Avoiding "10048 (Address socket bind error 10048 already in use.)" Errors in Webserver Stress Tool For high traffic scenarios this message shows a problem on the workstation running Webserver Stress Tool. The IP stack can't create additional outgoing TCP/IP connections because it runs out of available socket numbers for the IP address(es) that you have configured in Webstress. This error occurs when your workstation cannot allocate new sockets. On Windows the default limitation is 5000 - 1024 open sockets (5000 is the default max user port setting and the first 1024 ports are reserved). You can increase the default maximum socket value in the registry: HKEY_LOCAL_MACHINE/SYSTEM/CurrentControlSet/Services/Tcpip/Parameters and add or modify the MaxUserPort value. See Also Microsoft article: "When you try to connect from TCP ports greater than 5000 you receive the error 'WSAENOBUFS (10055)'" The Cable Guy article: "Windows TCP/IP Ephemeral, Reserved, and Blocked Port Behavior" Add comment Created on Feb 24, 2010 9:10:15 AM by Daniel Zobel [Paessler Support] Last change on Sep 1, 2015 8:07:43 AM by Erhard Mikulik [Paessler Support] Permalink Please log in or register to enter your reply. Disclaimer: The information in the Paess
SQL Server 2014 Express resources Windows Server 2012 resources Programs MSDN subscriptions Overview Benefits Administrators Students Microsoft Imagine Microsoft Student Partners ISV Startups TechRewards Events Community Magazine Forums Blogs Channel 9 Documentation APIs and reference Dev centers Retired content Samples We’re sorry.
Bind Error 10048 In Ip Messenger
The content you requested has been removed. You’ll be auto redirected in 1 download a 10048 error repair tool second. Ask a question Quick access Forums home Browse forums users FAQ Search related threads Remove From My Forums Asked by: winsock error 10048 address already in use Error 10048 in bind() Archived Forums # > .NET Framework Networking and Communication Question 0 Sign in to vote Hello, My application a simple MDI application.Take data in serial port and send it to another https://kb.paessler.com/en/topic/1213-how-can-i-solve-an-error-10048-address-already-in-use-in-webserver-stress-tool computer using tcp/ip .In the first iterartion every thing is fine.Both server and client systems works well.Then if the server is turned of off(disconnect using socket.close() method) and then client is also closed .without closing the application if i start open the socket and execute socket.bind() method , the exception 10048thanks in advance.cheers,watashi Wednesday, September 05, 2007 8:12 AM All replies 0 Sign in to vote It means that yProxy https://social.msdn.microsoft.com/Forums/en-US/77af3fe1-b322-4bf3-9aad-ce4da62d7457/error-10048-in-bind?forum=netfxnetcom is unable to bind to the Local (Proxy) Port that you have configured. That port is probably already in use. Wednesday, September 05, 2007 11:54 AM 0 Sign in to vote Hello, Thnks for u r reply.but as i hv stated the same application was using that ip and port and are closed using close() method.And then when try to open the same ip and port which was closed then i m getting the above error. Thursday, September 06, 2007 6:27 AM 0 Sign in to vote The problem is that binding and unbinding to endpoints is a costly operation for the Operating System.. And it takes a while before it is performed... If you want to speed up this process you'll have to find a way to pass in the option SO_REUSEADDR (i can't remember the .net equivalent right now) to notify the OS that the resource has to be cleaned up faster (and thus make it available faster)...serverSocket.SetSocketOption(SocketOptionLevel.IP, SocketOptionName.ReuseAddress, true);(Another interesting setting could be HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters\TcpTimedWaitDelay) Thursday, September 06, 2007 7:15 AM 0 Sign in to vote thnks a lot But i didnt get that interesting setting " HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters\TcpTimedWaitDelay)" Thursday, September 06, 2007 8:09 AM 0 Sign in to vote You can read about the setting in http://technet
Studio 2015 products Visual Studio Team Services Visual Studio Code Visual Studio Dev Essentials Office Office Word/Excel/PowerPoint Microsoft Graph Outlook https://msdn.microsoft.com/en-us/library/windows/desktop/ms737550(v=vs.85).aspx OneDrive/Sharepoint Skype Services Store Cortana Bing Application Insights Languages & platforms Xamarin ASP.NET C++ TypeScript .NET - VB, C#, F# Server Windows Server SQL Server BizTalk Server SharePoint Dynamics Programs & communities Students Startups Forums MSDN Subscriber downloads Sign in Search Microsoft Search Windows Dev Center Windows Dev Center Explore What’s new for error 10048 Windows 10 Intro to Universal Windows Platform Coding challenges Develop for accessibility Build for enterprise Windows Store opportunities Docs Windows apps Get started Design and UI Develop API reference Publish Monetize Promote Games Get started UI design Develop Publish Desktop Get started Design Develop API reference Test and deploy Compatibility Windows IoT Microsoft bind error 10048 Edge Windows Holographic Downloads Samples Support Why Windows Dashboard Explore What’s new for Windows 10 Intro to Universal Windows Platform Coding challenges Develop for accessibility Build for enterprise Windows Store opportunities Docs Windows apps Get started Design and UI Develop API reference Publish Monetize Promote Games Get started UI design Develop Publish Desktop Get started Design Develop API reference Test and deploy Compatibility Windows IoT Microsoft Edge Windows Holographic Downloads Samples Support Why Windows Dashboard Windows Sockets 2 Winsock Reference Winsock Functions Winsock Functions bind bind bind accept AcceptEx bind closesocket connect ConnectEx DisconnectEx EnumProtocols freeaddrinfo FreeAddrInfoEx FreeAddrInfoW gai_strerror GetAcceptExSockaddrs GetAddressByName getaddrinfo GetAddrInfoEx GetAddrInfoExCancel GetAddrInfoExOverlappedResult GetAddrInfoW gethostbyaddr gethostbyname gethostname GetHostNameW GetNameByType getnameinfo getipv4sourcefilter GetNameInfoW getpeername getprotobyname getprotobynumber getservbyname getservbyport GetService getsockname getsockopt getsourcefilter GetTypeByName htond htonf htonl htonll htons inet_addr inet_ntoa InetNtop InetPton ioctlsocket listen ntohd ntohf ntohl ntohll ntohs recv recvfrom RIOCloseCompletionQueue RIOCreateCompletionQueue RIOCreateRequestQueue RIODequeueCompletion RIODeregisterBuffer RIONotify RIOReceive RIOReceiveEx RIORegisterBuffer RIOResizeCompletionQueue RIOResizeRequestQueue RIOSend RIOSendEx select send