Intune App Wrapping Mobile Application Management Windows Windows 7 Windows 8 Windows 10 Azure AD AADConnect AADSync MDT Guides Tools Hyper-V Blog Roll André Picker error during connection to sms_site 67 David O'brien Henk Hoogendoorn Jan Ketil Skanke Jörgen Nilsson Niall
Error During Connection To Sms_site 5
Brady Ronni Pedersen Stefan Schörling Simon Dettling About me Contact There is no existing connection, Win32
There Is No Existing Connection, Win32 Error = 53
error = 53 System Center ConfigMgr > ConfigMgr > There is no existing connection, Win32 error = 53 Nickolaj November 28, 2012 0 Comments ConfigMgr, ConfigMgr
There Is No Existing Connection, Win32 Error = 21
2007, ConfigMgr 2012 A few weeks ago I saw that applications and packages was intermittently not being pushed over to our Secondary sites. When I looked in the sender.log I found the following:
There is no existing connection, Win32 error = 53
There is no existing connection, Win32 error = 53
there is no existing connection win32 error = 67 Error during connection to \\
Could not establish connection.
Attempt to connect failed. Every time I saw the problem, I tried to restart the SMS_Executive service on the Primary site. Suddenly all queued up sending packages started to go out to the Secondary sites. Okey, problem solved? No, it would after a random time stop to work again, and the same error appeared. My first suspicion was that the Primary site account was not added to the local group SMS_SiteToSiteConnection_
We have tier 3 structure as below CentralSite (CTS) - SCCM SP1 Primary Site 1 (PS1) Primary Site 2 (PS2) Primary Site 3 (PS3) 60 Secondary Site (S01-S60) 60 Secondary Site (T01-T60) 60Secondary Site (U01-U60) All sitestatus were not updating and showing critical. I have checked sender log at Central Site and it is not communicating to any other Primary Tiers. We rebooted all Central and Primary Site servers but no success. Error is as below: Sender.log (SERVER-CTS) Error during connection to \\SERVER-PS1\SMS_Site (1384). 18/04/2010 3:04:19 PM 7356 (0x1CBC) Operation is retryable. 18/04/2010 3:04:19 PM 7356 (0x1CBC) Sleeping http://www.scconfigmgr.com/2012/11/28/there-is-no-existing-connection-win32-error-53/ for 1 minutes before retrying 18/04/2010 3:04:19 PM 7356 (0x1CBC) There is no existing connection, Win32 error = 1384 18/04/2010 3:04:29 PM 7460 (0x1D24) There is no existing connection, Win32 error = 1384 18/04/2010 3:04:29 PM 7460 (0x1D24) Error during connection to \\SERVER-PS3.domain.net\SMS_Site (1384). 18/04/2010 3:04:29 PM 7460 (0x1D24) Operation is retryable. 18/04/2010 3:04:29 PM 7460 (0x1D24) Cannot connect to server SERVER-PS3.domain.net at remote site PS3, won't try http://www.networksteve.com/enterprise/topic.php/SCCM_Central_Site_not_communicating_to_Primary_Sites./?TopicId=13982&Posts=6 send requests going to site PS3 for an hour or until there are no active send requests. 18/04/2010 3:04:29 PM 7460 (0x1D24) There is no existing connection, Win32 error = 1384 18/04/2010 3:04:29 PM 7460 (0x1D24) There is no existing connection, Win32 error = 1384 18/04/2010 3:04:29 PM 7460 (0x1D24) Error during connection to \\SERVER-PS3\SMS_Site (1384). 18/04/2010 3:04:29 PM 7460 (0x1D24) Operation is retryable. 18/04/2010 3:04:29 PM 7460 (0x1D24) Sleeping for 1 minutes before retrying 18/04/2010 3:04:29 PM 7460 (0x1D24) There is no existing connection, Win32 error = 1384 18/04/2010 3:05:07 PM 6080 (0x17C0) There is no existing connection, Win32 error = 1384 18/04/2010 3:05:07 PM 6080 (0x17C0) Error during connection to \\SERVER-PS3\SMS_Site (1384). 18/04/2010 3:05:07 PM 6080 (0x17C0) Operation is retryable. 18/04/2010 3:05:07 PM 6080 (0x17C0) Cannot connect to server SERVER-PS3 at remote site PS3, won't try send requests going to site PS3 for an hour or until there are no active send requests. 18/04/2010 3:05:07 PM 6080 (0x17C0) Could not establish connection. 18/04/2010 3:05:07 PM 6080 (0x17C0) Attempt to connect failed. 18/04/2010 3:05:07 PM 6080 (0x17C0) Restart time = 18/04/2010 3:10:07 PM AUS Central Standard Time 18/04/2010 3:05:07 PM 6080 (0x17C0) We have 4 active connections 18/04/2010 3:05:07 PM
upgraded it a couple of months ago to SP2. I have http://www.networksteve.com/enterprise/topic.php/SCCM_Central_site_not_sending_information_to_Child_Primary/?TopicId=13014&Posts=3 been working on it again and found that changes made at the Central or Child sites are not replicating to each other, including package updates. http://www.verycomputer.com/46_0f397717e01294cf_1.htm I have found an error in the senders.log, but can't find anyone else that's really been experiencing this issue in the forums. The errors error during in this log state "There is no existing connection, Win32 error = 1326" & "Error during connection to \\child primary\sms_site (1326). Both server are on the same subnet. The Schedule.box inbox is full af files waiting to be replicated. Any help would be appreciated, thanks. July 28th, 2010 7:12pm Is error during connection the sms_site share present? John Marcum | http://myitforum.com/cs2/blogs/jmarcum | Free Windows Admin Tool Kit Click here and download it now July 28th, 2010 8:06pm Check the Site Address Account, Looks an account problem. what are you using computer account or domain account. July 28th, 2010 8:14pm Yep, that did it, thanks Kent. Once I removed and readded the Addresses for each site, they have started communicating again. Free Windows Admin Tool Kit Click here and download it now July 28th, 2010 9:24pm This topic is archived. No further replies will be accepted. Other recent topics Remote Administration For Windows. Easy remote access of Windows 10, 7, 8, XP, 2008, 2000, and Vista Computers Click here to find out more Reboot Hundreds of computers, disable flash drives, deploy power managements settings. Click here to get your free copy of Network Administrator. Over 25 plugins to make your life easier
component on my primary site server. This guy always lags behind with others when it comes to distributing the package. When I went thru the log I see the following messages: 1.There is no existing connection, Win32 error = 53 Error during WNetAddConnection2 to \\XXX_XXXX\SMS_SITE (53). Error is considered fatal. 2.There is no existing connection, Win32 error = 240 Heartbeat is expired. 3.There is no existing connection, Win32 error = 67 I installed hotfix(q330791) for SP4.Installation went successfully.I checked the logs & registry for HKLM\SOFTWARE\MICROSOFT\UPDATES.The following log tells post-hot fix errors on sender component. 1.Error during WNetAddConnection2 to \\FLFC6-ALLS01 \SMS_SITE (53). Error is considered fatal. This is the staus that I picked from the inboxes from the problem server & the good one. replmgr.box schedule.box schedule.box\outboxes\LAN schedule.box\requests schedule.box\tosend ready Good server 360 376 625 30 756 Bad Server 3761 3763 4073 567 7625 Basically what I see is sender lagging behind with the rest of the Primary Site Server's senders! any help in this direction would be greatly appreciated. thanks Top sender problems by Wally Mead [MS » Tue, 04 Feb 2003 08:56:37 Error 53 is network path not found. Either we couldn't resolve the computer name to an address to access, or the server was not available. Error 240 is the session was cancelled. I'm not familiar with that one, don't ever recall seeing it before. Error 67 is the network name cannot be found. That means we found the target computer on the network, but couldn't find the target share (in this case, I'm guessing it would be SMS_SITE). For each error, I'd manually try to do a "dir \\server\sms_site" to see if you can see the resource. There may not be any files, but at least see if you can see a connection established. -- This posting is provided "AS IS" with no warranties, and confers no rights. Quote:> The Server in question is running on Windows NT 4.0 with > SMS 2.0 sp4. I have been having issues with the sender > component on my primary site server. This guy always lags > behind with others when it comes to distributing the > package. When I went thru the log I see the following > messages: > 1.There is no existing connection, Win32 error = 53 > Error during WNetAddConnection2 to \\XXX_XXXX\SMS_SITE > (53). > Error is considered fatal. > 2.There is no exist