Error - Sv-uip Unconnected Interface Port
issue. The spec, and VCS, say it's illegal to haveunconnected ports of type interface. Normally, this isn't a problem.I'd either have a higher-level RTL module that connects the ports, ora testbench above the module that connects them. The problem is when Iwant to do a quick compile on just that module while developing it tocheck syntax, etc. I can't do this because VCS, and presumably othercompilers, error out on the unconnected interface ports.Does anyone have an easy solution to this? I could write a dummywrapper module, but I do this on dozens of different files, and thatstarts becoming a lot of work. I thought of some PERL script toautomatically create this wrapper, but I'm not the best PERLprogrammer, so it would take me a long time to get it working.Thanks for any solutions / suggestions,David Jonathan Bromley 2009-04-05 09:05:46 UTC PermalinkRaw Message Post by unfrostedpoptartThis has been giving me headaches as I start using SV Interfaces.Here's the issue. The spec, and VCS, say it's illegal to haveunconnected ports of type interface. Normally, this isn't a problem.I'd either have a higher-level RTL module that connects the ports, ora testbench above the module that connects them. The problem is when Iwant to do a quick compile on just that module while developing it tocheck syntax, etc. I can't do this because VCS, and presumably othercompilers, error out on the unconnected interface ports.Does anyone have an easy solution to this?By default, VCS does compilation and elaboration in asingle step (the "vcs" command). In Cadence and Mentorsimulators, you can run an independent compilation step(ncvlog, vlog) that syntax-checks the module(s) but doesnot attempt to do elaboration. I believe the same thingcan be done in VCS, and I *think* the command is "vlogan",but you'll need to check the docs yourself.Beware that thi
Error Parsing not working (Read 491 times) warnerrs Senior Community Member Posts: 107 Hero Points: 4 V20: User Defined Error Parsing not working « on: November 11, 2015, 05:23:35 pm » The following pattern and example work just fine in the error parsing Edit Expression dialog when I click Validate, but no messages are extracted from the build window.Code: [Select]^Error-\[?+\](:b)@{#3:?@}\n{#0:p},:b{#1:i}Code: [Select] sender_cov_bind
system
Error-[SV-UIP] Unconnected interface port
/rtl/common/ahb_matrix.sv, 43
"ahb_mstr_0_if"
The port 'ahb_mstr_0_if' of top-level module 'ahb_matrix' whose http://comp.lang.verilog.narkive.com/NOogXzXV/issue-compiling-modules-with-sv-interface-ports type is
interface 'ahb_lt_if' is left unconnected. It is illegal to leave the
interface ports unconnected.
Please make sure that all the interface ports are connected.
Error-[SV-UIP] Unconnected interface port
/rtl/common/ahb_matrix.sv, 44
"ahb_mstr_1_if"
The port 'ahb_mstr_1_if' of top-level module 'ahb_matrix' whose type is
interface 'ahb_lt_if' is left unconnected. It https://community.slickedit.com/index.php?topic=11775.0 is illegal to leave the
interface ports unconnected.
Please make sure that all the interface ports are connected.
Logged Clark SlickEdit Team Member Senior Community Member Posts: 3381 Hero Points: 201 Re: V20: User Defined Error Parsing not working « Reply #1 on: November 11, 2015, 11:01:29 pm » The regex you posted isn't valid.{#3:?@} isn't valid. I think you wanted {#3?@} Logged warnerrs Senior Community Member Posts: 107 Hero Points: 4 Re: V20: User Defined Error Parsing not working « Reply #2 on: November 13, 2015, 04:06:05 pm » Yes that is what I wanted, but it still doesn't work. I've attached screen caps of my settings. "VCS Error 4" is the pattern that should be getting matched. Screen Shot 2015-11-13 at 10.01.39 AM.png (177.35 kB, 600x563 - viewed 50 times.) Screen Shot 2015-11-13 at 10.02.13 AM.png (227.72 kB, 693x763 - viewed 44 times.) Logged Clark SlickEdit Team Member Senior Community Member Posts: 3381 Hero Points: 201 Re: V20: User Defined Error Parsing not working « Reply #3 on: November 13, 2
System Development Suite Related Products A-Z Tools Categories Debug Analysis Tools Indago Debug Platform https://community.cadence.com/cadence_technology_forums/f/30/t/9200 Indago Debug Analyzer App Indago Embedded Software Debug App Indago Protocol Debug App Indago Portable Stimulus Debug App SimVision Debug Emulation Tools Palladium Z1 Enterprise Emulation System Palladium XP Series Palladium Dynamic Power Analysis Palladium Hybrid SpeedBridge Adapters Emulation Development Kit Virtual error - JTAG Debug Interface Accelerated VIP QuickCycles Services Formal and Static Verification Tools JasperGold Formal Verification Platform (Apps) Assertion-Based Verification IP Incisive Formal Verification Platform FPGA-Based Prototyping Tools Protium Rapid Prototyping SpeedBridge Adapters Planning and Management Tools Incisive vManager Solution Simulation and Testbench Tools error - sv-uip Incisive Enterprise Simulator Cadence RocketSim Parallel Simulation Engine Incisive Functional Safety Simulator Incisive Specman Elite Software-Driven Verification Tools Perspec System Verifier Indago Portable Stimulus Debug App Indago Embedded Software Debug App Virtual System Platform Verification IP Tools Accelerated Verification IP Assertion-Based VIP Verification IP Flows Flows Verification Solution for ARM-Based Designs Automotive Functional Safety Metric-Driven Verification Signoff Mixed-Signal Verification Power-Aware Verification Methodology Digital Design and Signoff Digital Design and Signoff Overview CadenceĀ® digital design and signoff solutions provide a fast path to design closure and better predictability, helping you meet your power, performance, and area (PPA) targets. Full-Flow Digital Solution Related Products A-Z Tools Categories Block Implementation Tools Innovus Implementation System First Encounter Design Exploration and Prototyping Equivalence Checking Tools Conformal Equivalence Checker Functional ECO T