Connection Failed. Error The Remote Client/server Handshake Failed
NSXVirtual SAN vCenterFusionWorkstationvExpertVMware {code} CloudCredSubmit a Link Home > VMTN > VMware vCenter™ > Site Recovery Manager > Discussions Please enter a title. You can not post a blank message. Please type your message and try again. 1 2 Previous Next 18 Replies Latest reply: Dec 12, 2012 4:26 AM by kastlr SRM 5 + EMC VNX 5300 - Setup Array Manager IanTech Nov 17, 2011 3:38 AM Hi All,I have two VNX 5300 at each. I have managed to install SRM and paired the sites. I have setup everything else aside from the Array Manager. I have installed the SRA's on both SRM servers and the status is OK. I have downloaded the Virtual Appliance of the Solutions Enabler (7.2.1 and 7.3) from EMC Powerlink. I have also tried installing the windows version on the SRM server (7.3 and 7.2.1 both x64 and x86 versions). I have installed the VSI plugin for vSphere. The closest I get is when I click on the VSI plugin and select Solutions Enabler under Storage Viewer, I get the error " Connection failed. Error: The remote client/server handshake failed. The error I get when trying to add the Array Manager is " SRA command 'discoverArrays' failed. Unable to locate enabler for input connection information. Verify the Management IP/Hostname and credentials.Any idea'sThanks, 7943Views Tags: none (add) vnxContent tagged with vnx, srm5Content tagged with srm5 This content has been marked as final. Show 18 replies 1. Re: SRM 5 + EMC VNX 5300 - Setup Array Manager msatya Nov 22, 2011 3:11 AM (in response to IanTech) You do not have the options httpd.admin.access or httpd.admin.enable set appropriatly.-------------------------please award points if you see fit.Thanks Like Show 0 Likes (0) Actions 2. Re: SRM 5 + EMC VNX 5300 - Setup Array Manager IanTech Nov 24, 2011 1:57 AM (in response to msatya) Hi,Where would I f
UIM/P - Symmetrix VMAX Discovery (Verify SYMAPICertificates) December 18, 2013June 10, 2015 David Ring VblockCertificates, DISCOVERY, EMC UIM/P, SYMAPI, Symmetrix, UIM, Vblock, VMAX During a UIM discovery of an ‘EMC VMAX' you may encounter the following error: UIM/P - VMAX DISCOVERY ERROR MESSAGE: ================================================================= ================================================================= Action completed successfully… 10.X.X.X: found 1 reachable IP address out of 1 ping request Discovering device type and communication protocols for device (10.X.X.X) Device did not respond to authentication, please https://communities.vmware.com/thread/336690?tstart=0 check the supplied credentials and/or port(s). ---> Refer additional details below. ---> ---> ADDITIONAL DETAILS ---> SYM command ‘/opt/emc/SYMCLI/bin/symcfg list' failed with exit status: 1 [ERRORCODE 3 (Permission Denied)] ---> *** Verify SYMAPI client certificates are correct. *** ---> Command output: ---> > ---> > The remote client/server handshake failed. Please consult symapi and storsrvd https://davidring.ie/2013/12/18/emc-uimp-symmetrix-discovery-verify-symapi-certificates/ log files ---> > ---> ERR:Unable to get a session to Symmetrix 10.X.X.X using devicenative mechanism !!! Could not discover credentials for device ===================================================================== ===================================================================== If you experience the above error a common fix is to regenerate the certificate on the VMAX Agent server (SMI-S Provider) and to also regenerate the certificate on the UIM Host as per the following instructions: Firstly before proceeding with Cert regeneration check the following: 1. Date&Time Ensure the date and time is in sync between the UIM and VMAX Agent server. 2. Host File Entries Ensure the VMAX Agent server host file has an entry for the UIM Server; else you will receive the following error: 3. Support Matrix Search support.emc.com for: Unified Infrastructure Manager/Provisioning Support Matrix Ensure the SE version listed is the version installed. 4. ECOM Service Also check that the ECOM service is running on the VMAX Agent server and the correct ECOM credentials are being used. Validate the credentials by logging in
- Notes for day to day operation by sanaswati on 13/05/2013 in EMC DISCLAIMER:Information mentioned below as been compiled from various sources such as first hand experience by myself and http://www.sanspire.com/emc-notes-for-day-to-day-operation/ my colleagues, from webpages searched via google etc. I do not take credit for https://kb.netapp.com/support/s/article/how-to-configure-dmx-v-max-symmetrix-in-oncommand-balance the tips mentioned below. If a linux host using QLogic card is seeing 18 paths per disk instead of 2, chances are you might need to Enable SPC2 version for that host's wwn on a particular dir/port # symmask -sid 1234 -wwn 1000000000000000 set hba_flags on SPC2 -enable -dir 08C -p 1 # symmaskdb -sid 1234 connection failed. list database -v -dir 08C -p 1 Originator Port wwn: 1000000000000000 Type : Fibre User-generated Name: hostA/qla1 Visibility : No FCID Lockdown: No Lun Offset : No Heterogeneous Host : No Port Flag Overrides: Yes Enabled: SPC2_Protocol_Version(SPC2) Disabled : N/A Dynamic Addressing : No Authentication State : N/AG Devices: 1003 1007 100B How do you import connection failed. error BCV devices in Veritas? Steps to import the clone disk (including EMC BCVs) using VxVM 5.0 : 1) Before we split the BCV device from testdg (as in example below), "vxdisk list" shows the clone disk in an error udid_mismatch status DEVICETYPEDISKGROUP STATUS EMC0_1auto:cdsdiskEMC0_1testdgonline EMC0_2auto:cdsdisk- - errorudid_mismatch 2) Split the BCV device # symmir -g testdg split DEV001 3) After we split the BCV device DEV001 from testdg, we need to issue "vxdctl enable" or "vxdisk scandisks" to update the configuration in order to seee clone disk is in "online udid_mismatch" state issuing "vxdctl enable" ( or "vxdisk scandisks"). DEVICETYPEDISKGROUP STATUS EMC0_1auto:cdsdiskEMC0_1testdgonline EMC0_2auto:cdsdisk- - onlineudid_mismatch 4) Use the following command to import the clone disk # vxdg -n newdg -o useclonedev=on -o updateid import testdg 5) Issue "vxdisk list" to see the clone disk is imported DEVICETYPEDISKGROUP STATUS EMC0_1auto:cdsdiskEMC0_1testdgonline EMC0_2auto:cdsdiskEMC0_1newdg onlineclone_disk How to interpret inq/syminq output? When running inq or syminq, you'll see a column titled Ser Num. This column has quite a bit of information hiding in it. DeviceProduct Device ----------------------------------------- -------------------------------- NameTypeVendorIDRev Ser Num Cap(KB) --------------------- ------- --------- ------- --------- -------- /dev/dsk/c1t0d0 EMC SYMMETRIX 526573009150459840 /dev/dsk/c1t4d0 BCV EMC SYMMETRIX 526573010150459840 /dev/dsk/c1t5d0 GKEMC SYMMETRIX 5265730191502880 /dev/dsk/c2t6d0 GKEMC SYMMETRIX 52657301A2812880 Using the first and last serial numbers