Error Cpu Slave 3 Timeout
Contents |
Enterprise 420R CPU Slave timeout Sun workstations/servers and operating systems (SunOS, Solaris and OpenSolaris) Forum rules Any posts concerning pirated software or offering to buy/sell/trade commercial software are subject to removal. Post Reply Print view Search Advanced search First unread post • 4 posts •
Connection Refused Error In Jmeter
Page 1 of 1 injection Posts: 9 Joined: Thu Jun 02, 2011 6:52 pm Location: Atlanta, jmeter memory settings Georgia Contact: Contact injection AOL Sun Enterprise 420R CPU Slave timeout Quote Unread postby injection » Sat Apr 09, 2016 8:42 pm Last jmeter connection refused to host weekend I bought a Sun E420R that had maxed out RAM and CPU but once brought it home and powered it on everything was fine until slave CPUs 1-3 started timing out. I have already replaced the motherboard and tested
Jmeter Hangs Up
each CPU in slot 0 to make sure that they all work and I still have the same problem. Could this be because the NVRAM is dead or is it another problem?I have tried looking in the Sun manual and I couldn't find much to guide me to fixing this issue. Any help would be helpful. Top escimo Posts: 35 Joined: Sat Mar 22, 2008 4:07 am Location: Frankfurt/Main, Germany Contact: Contact escimo YouTube Re: Sun Enterprise 420R CPU
Jmeter Thread Hangs
Slave timeout Quote Unread postby escimo » Sun Apr 10, 2016 7:16 am So the NVRAM is dead? What do you mean with timeout?Is it possible to get more input?- console output and/or messages- PROM version- board part# and revision (type is the same used for Ultra 80 workstations)- CPU part#' SPARC: Sun SPARCstation 2 (V7, 1990), Sun Blade 2000 (V9, 2002)x86: Siemens Nixdorf PCD-4H/33 (i486, 1993), Siemens Nixdorf Scenic Pro C5 (i586, 1996) Top injection Posts: 9 Joined: Thu Jun 02, 2011 6:52 pm Location: Atlanta, Georgia Contact: Contact injection AOL Re: Sun Enterprise 420R CPU Slave timeout Quote Unread postby injection » Sun Apr 10, 2016 7:47 am After the RAM test the 420R will display CPU Slave #3 timeout for slot 3 and the same applies for slots 1 & 2. It seems like only slot 0 is populated will the machine pass POST. I'm not at home right now but when I get back I'll post the CPU and MB part numbers. Top escimo Posts: 35 Joined: Sat Mar 22, 2008 4:07 am Location: Frankfurt/Main, Germany Contact: Contact escimo YouTube Re: Sun Enterprise 420R CPU Slave timeout Quote Unread postby escimo » Sun Apr 10, 2016 9:41 am Once before, in the first days I had also serveral problems with my Ultra 80 It's because somtimes CPU modules and memory riser board are not installed properly.A non-dead NVRAM (battery) also woul
Skip over Search Skip over Site Explorer Site ExplorerSite Explorer Search Product Support Services Forum mySupport Navigation CP341 ModBus errors ? Created by: Glenn@CNCDesign at: 1/14/2015 4:08 AM (3 Replies) Rating (0) Thanks 0 Actions New post 4 Entries java.net.connectexception connection refused connect in jmeter 1/14/2015 4:08 AM Rate (0) Glenn@CNCDesign Regular Member Joined: 9/29/2005 Last visit: 10/10/2016
Jmeter Issues
Posts: 38 Rating: (0) I am getting the following errors from my CP341Where can I find the cause or explanation of jmeter remote testing these ?Diagnostic buffer of module CP 341-RS422/485 Order No./ Description Component Version 6ES7 341-1CH02-0AE0 Hardware 2 - - - Firmware V 2.1.6 Rack: 0Slot: 4 Serial number: S C-EOTP58172014 Event 1 of 9: Event ID http://forums.nekochan.net/viewtopic.php?t=16730588 16# F1C8:0E30IF 1: Internal error during data transfer to CPU: Unexpected acknowledgment Passive.Incoming event (Coding: 16# F1C8 0E30 0100 0000 0000 0000) Event 2 of 9: Event ID 16# F1C8:0E31IF 1: Timeout during data transfer to CPU.Incoming event (Coding: 16# F1C8 0E31 0100 0000 0000 0000) Event 3 of 9: Event ID 16# F1C8:0E30IF 1: Internal error during data transfer to CPU: Unexpected acknowledgment Passive.Incoming event (Coding: 16# F1C8 0E30 0100 https://support.industry.siemens.com/tf/ww/en/posts/cp341-modbus-errors/120312/?page=0&pageSize=10 0000 0000 0000) Event 4 of 9: Event ID 16# F1C8:0E31IF 1: Timeout during data transfer to CPU.Incoming event (Coding: 16# F1C8 0E31 0100 0000 0000 0000) Suggestion To thank Quote Answer 1/14/2015 12:45 PM Rate (0) Arno81 Experienced Member Joined: 9/20/2013 Last visit: 9/14/2016 Posts: 98 Rating: (9) Hello Glenn,it´s recommended to call the rcv-FB withe EN_R = true every cycle! Is it so in your plc-programm? Suggestion To thank Quote Answer 1/15/2015 4:59 AM Rate (0) Glenn@CNCDesign Regular Member Joined: 9/29/2005 Last visit: 10/10/2016 Posts: 38 Rating: (0) Arno81Hello Glenn,it´s recommended to call the rcv-FB withe EN_R = true every cycle! Is it so in your plc-programm?Arno81, I now have this bit EN_R SET True all the timeIssue now is for 3 devices (Altivar 61 drives) I get this message at the CPHow to determine what this means ? this error is not in the CP341 ManualEvent 1 of 9: Event ID 16# F1C8:0830IF 1: MODBUS receive errorMaster: Timeout waiting for response frameSlave: Broadcast not permitted with this function code.Incoming event(Coding: 16# F1C8 0830 0100 0000 0000 0000)settings on the drive seem correct, (Address, Baudrate and Format)Function code = #03On this same Network are 6x MicroDrive ELite drives that are communicating OKPLC code for
Skip over Search Skip over Site Explorer Site ExplorerSite Explorer Search Product Support Services Forum mySupport Navigation CPU1214 & CB1241. Does not answer from modbus question Created by: wolka at: 5/24/2016 12:43 PM (5 Replies) Rating (0) Thanks 0 Actions New post 6 Entries 5/24/2016 https://support.industry.siemens.com/tf/ww/en/posts/cpu1214-cb1241-does-not-answer-from-modbus-question/149511?page=0&pageSize=10 12:43 PM Rate (0) wolka Experienced Member Joined: 3/26/2009 Last visit: 8/25/2016 Posts: 73 Rating: http://unix.derkeiler.com/Mailing-Lists/SunManagers/2007-01/msg00123.html (0) I have Modbus RTU network with CPU 224 master and some CPU 224 and CPU 1214 as slaves. One of CPU 1214 doesn't answer from master questions. MBUS_MSG Master-command for this slave CPU produces an error, "3" - timeout.All CPU 1214 slaves have tha same CB1214 communication plate and use the same command - MB_SLAVE.On the problematic node MB_SLAVE commands connection refused DR regularly turn ON - it means that PLC receives query and understands it.The RX TX indicators analysis show that the one of CPU does not respond to a modbus request.I changed on the problematic node the CB1241 board - did not help, so I changed (as experiment) dimension addresses - nothing has changed. AttachmentMB 224--1214.jpg (18 Downloads) Last edited by: wolka at: 5/24/2016 12:48:24 PM Suggestion To thank Quote Answer 5/24/2016 2:38 PM Rate (0) Duris_I error cpu slave Platinum Member Joined: 4/28/2015 Last visit: 10/10/2016 Posts: 1902 Rating: (127) Hello,but what about ERROR and STATUS values? With kind regards...Duris_I Suggestion To thank Quote Answer 5/24/2016 4:10 PM Rate (0) wolka Experienced Member Joined: 3/26/2009 Last visit: 8/25/2016 Posts: 73 Rating: (0) Duris_IHello, but what about ERROR and STATUS values?#ER there is always FALSE and #STATUS is #00, #DR after a request from the master for one cycle becomes to TRUE.If the master CPU224 by MBUS_MSG command call another plc with a different MB address, the answer comes normally Last edited by: wolka at: 5/24/2016 4:11:03 PM Suggestion To thank Quote Answer 5/25/2016 7:46 AM Rate (0) Duris_I Platinum Member Joined: 4/28/2015 Last visit: 10/10/2016 Posts: 1902 Rating: (127) Hello,can you post info about wiring that stations? The problematic PLC is at end of line or somewhere in middle? I point to propper termination if it's needed. With kind regards...Duris_I Suggestion To thank Quote Answer 5/25/2016 8:00 AM Rate (0) wolka Experienced Member Joined: 3/26/2009 Last visit: 8/25/2016 Posts: 73 Rating: (0) Duris_IHello. The problematic PLC is at end of line or somewhere in middle? I point to propper termination if it's needed.The problematic PLC is in midle of the line. Terminator in ends of line is turn on. Suggestion To thank Quote Answer 5/25/2016 8:19 AM Rate (0) Duris_I Plat
power spikes. Then i managed to record the follwoing error: ERROR: System "FATAL RESET" from DAR/DCS/MDR System State (CPU7 reporting) CPU0 Config/Control/Status registers: CPUVersion: 003e.0015.b100.0507 SafConfig: 0caa.01bc.2000.0002 ... Finaly the server stoped rebooting with report from the POST for failed tests for Motherboard/Centerplan and advice the same to be replaced. We then decided to order a new server base for V880 and today we have managed to replace the old Motherboard/Centerplan board and old IO board with the new ones. When we powered on the server, today, the POST has stopped with the following errors: 3>Halting all other processors. 3>ERROR: Unexpected Trap! 3>H/W under test = Safari bus CPU 3, Motherboard/Centerplane 3>END_ERROR and after soft reset: 3>Start selftest... 3>Waiting for slave CPU=0, timeout in 3 seconds... 3>Waiting for slave CPU=0, timeout in 2 seconds... 3>Waiting for slave CPU=0, timeout in 1 seconds... 3>ERROR: TEST = Power on Reset Initialization 3>H/W under test = CPU, Motherboard/Centerplan, I/O board, (system init) 3>MSG = ERROR: Slave timeout waiting for 0 to finish, offlining cpu! 3>END_ERROR 3>INFO: Reset Module with CPUs 0 2, both have been offlined. 3>ERROR: TEST = Power on Reset Initialization 3>H/W under test = CPU, Motherboard/Centerplan, I/O board, (system init) 3>MSG = ERROR: Slave timeout waiting for 1 to finish, offlining cpu! 3>END_ERROR 3>INFO: Reset Module with CPUs 1 3, both have been offlined. and the server got frozen completely. I had to reset it from the power switch and for my pleasure it passed all tests and booted the OS. After 5-6 mins of work the 2 months old problem raised again -- the kernel paniced itself and machine rebooted ... Could someone lead me to the possible roots of the real problem? Thanks in advance! Vladimir ________________________