Respironics Bipap Autosv Error Codes
Workings of a CPAP machine Author Message SuperSleeper Posts: 9,839 Joined: Feb respironics bipap pro 2 error codes 2012 Machine: PR System One REMstar Auto (DS560) Mask Type: Nasal pillows Mask Make & Model: ResMed Mirage Swift II Humidifier: none
Respironics Cpap Error Codes
CPAP Pressure: 12.5 - 18.5 cmH20 (auto range) CPAP Software: SleepyHead Other Comments: Have diabetes Type II Sex: Male Location: Illinois, USA Post: #1 Service Required Error Codes - Inner Workings of a CPAP machine [note: respironics bipap error codes some parts of this thread were copied from our old forum] dunhamg Wrote:Is there something that I can do to reset something, I am leaving for vacation first thing in the morning to Mexico for the week. Last night my Remstar Pro M with AFlex gave me this message. I checked the clinician menu and didn't see anything there. Thanks for any help. Grady 02-25-2012 07:16 PM Donate to Apnea Board SuperSleeper remstar pro error codes Posts: 9,839 Joined: Feb 2012 Machine: PR System One REMstar Auto (DS560) Mask Type: Nasal pillows Mask Make & Model: ResMed Mirage Swift II Humidifier: none CPAP Pressure: 12.5 - 18.5 cmH20 (auto range) CPAP Software: SleepyHead Other Comments: Have diabetes Type II Sex: Male Location: Illinois, USA Post: #2 RE: Service Required Error Codes - Inner Workings of a CPAP machine [copied] Hi Grady, welcome to Apnea Board! To help diagnose the issue, it should give you an error code of some type... Is there a specific error code or does it simply say "Service Required"? Also, does your machine have a smart card? If so, try removing the card and seeing if that solves the problem. Here are the Error Codes for REMstar Machines: Error Code - Description - Probable Cause - Corrective Action E-0 NO_ERROR •Reserved •N/A E-1 ERR_SOFTWARE •Reserved •Replace Main PCA E-2 ERR_PROGRAM_CRC_FAILURE •Defective FLASH chip •Replace Main PCA E-3 ERR_EXTERNAL_RAM_FAILURE •Defective RAM chip •Replace Main PCA E-4 ERR_FIQ_STACK_OVERFLOW •Defective RAM chip •Replace Main PCA E-5 ERR_FIQ_STACK_UNDERFLOW •Defective RAM chip •Replace Main PCA E-6 ERR_NEST_STACK_OVERFLOW •Defective RAM chip •Replace Main PCA E-7 ERR_NEST_STACK_UNDERFLOW •Defective RAM chip •Replace Main PCA E-8 ERR_IRQ_STACK_OVERFLOW •Defective RAM chip •Replace Main PCA E-9 ERR_IRQ_STACK_UNDERFLOW •Defective RAM chip •Replace Main PCA E-10 ERR_TMR_STACK_OVERFLOW •Defective RAM chip
Refer to the "see also" section of this page for more information regarding the tones. If the machine only says "Service Required", it is usually a
Philips Respironics System One Error Codes
fatal error. This will happen with water damage that has caused a remstar shuttle error codes short circuit. Below are the error codes for the REMstar xPAP machines. Please note: these codes are for older pre-2007
Respironics Bipap St
REMstar machines. For the newer PR System One machines, go to Philips-Respironics error codes. Contents 1 E-0 - E-20 2 E-21 - E-40 3 E-41 - E-60 4 E-61 - E-80 5 http://www.apneaboard.com/forums/Thread-CPAP-Service-Required-Error-Codes-Inner-Workings-of-a-CPAP-machine E-80 - E-86 6 See Also E-0 - E-20 Error Code Description Probable Cause Corrective Action E-0 NO_ERROR Reserved N/A E-1 ERR_SOFTWARE Reserved Replace Main PCA E-2 ERR_PROGRAM_CRC_FAILURE Defective FLASH chip Replace Main PCA E-3 ERR_EXTERNAL_RAM_FAILURE Defective RAM chip Replace Main PCA E-4 ERR_FIQ_STACK_OVERFLOW Defective RAM chip Replace Main PCA E-5 ERR_FIQ_STACK_UNDERFLOW Defective RAM chip Replace Main PCA E-6 ERR_NEST_STACK_OVERFLOW Defective RAM chip Replace Main http://www.apneaboard.com/wiki/index.php?title=REMstar_error_codes PCA E-7 ERR_NEST_STACK_UNDERFLOW Defective RAM chip Replace Main PCA E-8 ERR_IRQ_STACK_OVERFLOW Defective RAM chip Replace Main PCA E-9 ERR_IRQ_STACK_UNDERFLOW Defective RAM chip Replace Main PCA E-10 ERR_TMR_STACK_OVERFLOW Defective RAM chip Replace Main PCA Error Code Description Probable Cause Corrective Action E-11 ERR_TMR_STACK_UNDERFLOW Defective RAM chip Replace Main PCA E-12 ERR_SVC_STACK_OVERFLOW Defective RAM chip Replace Main PCA E-13 ERR_SVC_STACK_UNDERFLOW Defective RAM chip Replace Main PCA E-14 ERR_THREAD_STACK_OVERFLOW Defective RAM chip Replace Main PCA E-15 ERR_ARM_UNDEFINED_INSTRUCTION_EXCEPTION Defective FLASH chip Replace Main PCA E-16 ERR_ARM_SWI_EXCEPTION Defective FLASH chip Replace Main PCA E-17 ERR_ARM_PREFETCH_EXCEPTION Defective FLASH chip Replace Main PCA E-18 ERR_ARM_ABORT_EXCEPTION Defective RAM chip Replace Main PCA E-19 ERR_ARM_RESERVED_EXCEPTION Defective FLASH chipDefective microprocessor Replace Main PCA E-20 ERR_AIC_DEFAULT_HANDLER Defective FLASH chip Replace Main PCA E-21 - E-40 Error Code Description Probable Cause Corrective Action E-21 ERR_AIC_SPURIOUS_HANDLER Defective FLASH or RAM chip Replace Main PCA E-22 ERR_CAL_DATA_CRC_FAILURE Improper calibrationDefective FLASH chip RecalibrateReplace Main PCA E-23 ERR_INVALID_DRIFT_INDEX_AT_CAL Improper calibrationOccluded or restricted pressure tubeDefective flow sensor RecalibrateReplace pressure tubeReplace Main PCA E-24 ERR_UNRECOGNIZED_CAL_VERSION_BY_SW Improper calibrationDefective FLASH chip RecalibrateReplace Main PCA E-25 ERR_DRIFT_FLOW_TOO_HIGH Occluded or restricted pressure tubeDefective flow sensor Replace Flow TubeReplace Main PCA E-26 ERR_UI_DISPLAY_FAILURE Defective LC
from CPAP users that have a malfunctioning CPAP or BiPAP machine that needs repaired or serviced. It sounds to me that some of the home health care companies are dropping the ball when http://cpap.1800cpap.com/blog/tag/cpap-machine-errors/ it comes to explaining how CPAP warranty and repair should be handled if their patient ever finds themselves in this predicament. Know your rights as the user and consumer of these CPAP products Service and Repair Finding a CPAP repair shop can be as difficult as locating a watery oasis in the desert. These devices are such a specialty that most people don’t know where to turn to. The average life error codes span of a CPAP or BiPAP machine will vary from usually 5-7 years. We do hear of stories of machines lasting 12-13 years but come on, Bigfoot is real too, huh? For repair or service, you should contact the place or company that set you up with the equipment. From there, if it’s not covered under warranty, they will send it to the CPAP manufacturer for a repair estimate. Once a bipap error codes repair cost estimate has been established, it is then up to you to decide if you wish to have it repaired or purchase a new one. From what we have seen, it can be a better cost savings to you to purchase new then to have a defective unit repaired for hundreds of dollars. If you choose the process to have it repaired you need to ask your home healthcare equipment provider if they will be willing to let you use a “loaner” in the interim. It varies from manufacturer to manufacturer as to the time frame of a CPAP repair. Warranty Did you know your CPAP and/or BiPAP machine comes with a manufacturer warranty. For most manufacturers like ResMed and Philips Respironics, the CPAP machine warranty is valid for 2 years; with Fisher and Paykel it’s 2.5 years. With these CPAP warranties, the machine is typically replaced, not repaired, so you get a new one! How about the humidifier? Sometime the machine works fine but you get that error code message on the CPAP machine that states something is wrong with the humidifier. Good news; the CPAP humidifier is covered under that warranty too! The next obvious question is “What do I do next?”. You need to contact the provi