Fanuc Power Supply Error Codes
Contents |
Servo Fanuc Alpha Power Fanuc AC Spindle Unit Fanuc 10 & 11 Fanuc 6 Fanuc Component Fanuc Part Numbers Fanuc Services Fanuc Drives Fanuc α Servo Module Fanuc α Spindle SPM Fanuc α fanuc power supply alarm codes Power PSM Fanuc α Servo SVU Fanuc αiPS Power Supply Fanuc β Servo fanuc error codes pdf SVU Fanuc aiSP Spindle Fanuc aiSV Servo Fanuc Servo Amps Fanuc AC Spindle Fanuc Axis Drives Fanuc Transistors Fanuc Controls fanuc robot error codes Fanuc Control Series Fanuc Power Supply Units Fanuc Monitors Fanuc Mono CRT Exchange Fanuc Membranes Fanuc Memory Replacement Fanuc Motors Fanuc Alpha Servo Motors Fanuc AC Servo Motors Fanuc DC Axis Motors Fanuc
Fanuc Rj3 Error Codes
Spindle Motors Fanuc Encoders CNC Monitor Mazak Monitors Siemens Monitors Mitsubishi Monitors Hitachi Monitors Heidenhain Monitors Sharp Monitors, LCD Other CNC Parts CNC Machine Tools CNC Electronics Inc Fanuc Testing Fanuc Alarm Code Fanuc Alpha Power Supply Fanuc Alpha Power Supply Fanuc Alpha Power Supply Module Alarms CNC has put to together a simple alarm list. If an alarm / error occurred on your Fanuc alpha fanuc rj3ib error codes power module. Then check the front of the unit looking at its 2 digit 7-bit displays which should indicate an alarm number / code. Once you have these details look below, then contact us and we will see if we can assist you either with a testing, repair or exchange part if it seems the Fanuc alpha power supply module is faulty. Alarm Code Description 1 Overcurrent flowed into the input of the main circuit. 2 A cooling fan for the control circuit has stopped. 3 The temperature of the main circuit heat sink has risen abnormally. 4 In the main circuit the DC voltage (DC link) has dropped. 5 The main circuit capacitor was not charged with the specific time. 6 The control power supply voltage decreases. 7 In the main circuit the DC voltage at the DC link is abnormally high. 8 There is excessive short-term regenerative power A A cooling fan of external cooling has stopped. E The input power supply is abnormal (open phase) H The temperature of the regenerative resistor has risen abnormally. We do not offer the advice that an on site Fanuc trained maintenance engineer can. for Fanuc Parts Call:Telephone+1-434-9
Servo Fanuc Alpha Power Fanuc AC Spindle Unit Fanuc 10 & 11 Fanuc 6 Fanuc Component Fanuc Part Numbers Fanuc Services Fanuc Drives Fanuc α Servo Module Fanuc α Spindle SPM Fanuc α Power PSM Fanuc α fanuc error codes list Servo SVU Fanuc αiPS Power Supply Fanuc β Servo SVU Fanuc aiSP Spindle Fanuc
Fanuc 16i Error Codes
aiSV Servo Fanuc Servo Amps Fanuc AC Spindle Fanuc Axis Drives Fanuc Transistors Fanuc Controls Fanuc Control Series Fanuc Power Supply
Fanuc Power Supply Module
Units Fanuc Monitors Fanuc Mono CRT Exchange Fanuc Membranes Fanuc Memory Replacement Fanuc Motors Fanuc Alpha Servo Motors Fanuc AC Servo Motors Fanuc DC Axis Motors Fanuc Spindle Motors Fanuc Encoders CNC Monitor Mazak Monitors http://cnc-electronics.com/fanuc-testing/fanuc-alarm/fanuc-alpha-power-supply/ Siemens Monitors Mitsubishi Monitors Hitachi Monitors Heidenhain Monitors Sharp Monitors, LCD Other CNC Parts CNC Machine Tools CNC Electronics Inc Fanuc Testing Fanuc Alarm Code Fanuc Alpha Power Supply Fanuc Alpha Power Supply Fanuc Alpha Power Supply Module Alarms CNC has put to together a simple alarm list. If an alarm / error occurred on your Fanuc alpha power module. Then check the front of the unit looking at its http://cnc-electronics.com/fanuc-testing/fanuc-alarm/fanuc-alpha-power-supply/ 2 digit 7-bit displays which should indicate an alarm number / code. Once you have these details look below, then contact us and we will see if we can assist you either with a testing, repair or exchange part if it seems the Fanuc alpha power supply module is faulty. Alarm Code Description 1 Overcurrent flowed into the input of the main circuit. 2 A cooling fan for the control circuit has stopped. 3 The temperature of the main circuit heat sink has risen abnormally. 4 In the main circuit the DC voltage (DC link) has dropped. 5 The main circuit capacitor was not charged with the specific time. 6 The control power supply voltage decreases. 7 In the main circuit the DC voltage at the DC link is abnormally high. 8 There is excessive short-term regenerative power A A cooling fan of external cooling has stopped. E The input power supply is abnormal (open phase) H The temperature of the regenerative resistor has risen abnormally. We do not offer the advice that an on site Fanuc trained maintenance engineer can. for Fanuc Parts Call:Telephone+1-434-971-1394 (EST)+1-619-477-9011 (PST)Fanuc Parts & CNC PartsFanuc Alpha Module Fanuc Drives Fanuc Control Fanuc Motor Fanuc Monitor Fanuc Power Supply Unit CNC Monitors C
alpha series, fanuc, power supplyJoe Kaminski Recently we had a customer who was working on troubleshooting a Fanuc power supply alarm that he had on a machine. He was wondering what the different codes stood for, so we wanted https://www.mroelectric.com/blog/fanuc-power-supply-alarm/ to go ahead and list the different alarm codes for this series. These codes apply https://fanucrepairs.wordpress.com/tag/fanuc-alarms/ to power supplies that start with the following prefixes. The "X"s after the H will be numbers, so an example part number is A06B-6087-H130. A06B-6081-HXXX A06B-6083-HXXX A06B-6077-HXXX A06B-6091-HXXX A06B-6120-HXXX A06B-6140-HXXX A06B-6110-HXXX Here is a list of the alarm codes for these series of Power Supply Modules. AL01: The main circuit power module (IPM) has detected am Error (PSM-5.5,-11) Overcurrent error codes flows into the input of the main circuit (PSM-15 to –30). AL02: A cooling fan for the control circuit has stopped. AL03: The Temperature of the main circuit heat sink has risen abnormally. AL04: In the main circuit the DC voltage (DC Link) has dropped. AL05:The main circuit capacitor was not recharged within the specified time. AL06: The Input Power Supply is abnormal (open phase). AL07: In the main circuit the DC Voltage at the fanuc power supply DC link is abnormally high. A06B-6087-H130 alarm codes Post navigation ← Software for Programming Modicon Quantum PLCs Restoring Fanuc Beta Drive Parameters → 2 thoughts on “Fanuc Power Supply Alarm Codes - Alpha Series” Ignacio Castaneda says: March 1, 2016 at 8:31 pm Hello, I have a FANUC power supply model: A068-6077-H106. AlM: 02 "Cooling fan has stopped" I just replaced with after market, same specs, new fan it is working now. BUT, Alarm still is on display. How to reset it? Thank you for your assistance and your time. Reply Gowdam says: June 17, 2016 at 4:30 am me too having same problem 01 alarm Reply Leave a Reply Cancel reply Your email address will not be published. Required fields are marked *Comment Name * Email * Website Interested in purchasing a part? Request a Quote! (800) 691-8511 Search for: Recent Posts Yaskawa Motoman Swordfighter Human Machine Interface (HMI) Retrofitting Industrial Legacy Systems UNI3404: Beyond the User Manual A06B-6058-H005: Beyond the User Manual Archives September 2016 August 2016 July 2016 June 2016 May 2016 April 2016 March 2016 February 2016 January 2016 December 2015 November 2015 October 2015 September 2015 August 2015 July 2015 June 2015 May 2015 April 2015 March 2015 March 2014 February 2014 November 2013 October 2013 September 2013 Categories Commander SE Configuration Control Techniq
June 8, 2016July 6, 2016 fanucrepairs fanuc, Fanuc Repair, Uncategorized fanuc, fanuc alarms, fanuc fault finding, fanuc faults, fanuc part numbers, fanuc repairs, fanuc spares We are happy to take on repairs of your Fanuc Parts. To help us do this please fill in the contact form at the bottom of the page The details we would need are The part number of your Fanuc item The more fault details you could supply is with the better, For example if it is a Fanuc Alpha Drive it is good for us to know if you have a alarm code displayed on the 7 segment display of the drive, any alarm messages on your Fanuc CNC and a bit of history of regarding the fault would be of use. We have undertaken various repairs, From simple jobs like Fanuc Servo Drive's that required a quick change of a blown transistor which then was retested on our closed loop Fanuc Test Rig, To jobs like the Fanuc AC Spindle Drive below. This A06B-6055-H206 Fanuc AC Spindle Drive was sent to us for repair with a reported "Alarm 12 and or Alarm 03 problems" As we looked into the drive we found it was not just a case of one or two components causing the problem but a multitude of parts. The below photo contains all the components we found to be faulty. Components are from the base and the A20B-1001-0120 Top Card The components were replaced and the base and the top card checked. Once satisfied all the broken components had been changed and all circuits checked so no further damage would occur we then tested then drive and left it cycling our Fanuc Spindle Motor before returning to the customer. If you have need of a repair please contact us Name(required) Email(required) Company Comment(required) Leave a comment Fault Finding On Fanuc Alpha Spindle AmplifierModules July 9, 2015July 14, 2016 fanucrepairs Fanuc Alarms, Fanuc Spindle Drives fanuc, fanuc alarms, fanuc alpha spindle, fanuc spindle alarm, fanuc spindle drive, fanuc spindle module, fanuc spm How to test if a spindle drive is faulty? Firstly, the correct operation of the spindle