Hamilton Validator Error Codes
Contents |
try the following: Load the page again by clicking the Refresh button
Hamilton Coin Changer Error Codes
in your web browser. Open the www.autocareforum.com home page, then try to open another page. Click the Back button to try another link. The www.autocareforum.com forum technical staff have been notified of the error, though you may contact them if the problem persists. We apologise for any inconvenience.
the validator. The sticker has the serial number, model, version, and date of manufacture of your validator. In case the eprom has
Hamilton Bill Changer
been changed in the validator and the sticker wasn’t updated, on an XE validator; with the power ON, turn all of the dip switches to the OFF position, then turn ON switches (in this order) 9 and 1. The display will flash 3 numbers; this is the version installed in the validator. My validator rejects too many bills, how can I http://www.autocareforum.com/showthread.php?7448-Hamilton-XE-Validator improve the acceptance rate? Setting up a regular maintenance schedule is recommended. Depending on use, the validator should be cleaned and calibrated every 2-4 months. What should I use to clean my validator? Use rubbing alcohol and cotton balls or Q-tips. How often should I clean my validator? Depending on use, the validator should be cleaned every 2-4 months. How do I http://www.hamiltonservices.org/Documents/shopframes/faq.php clean my validator? ** Always turn the power OFF when disconnecting and reconnecting the validator ** The XE series: There are (2) nickel-sized latch studs on the validator, (1) on each side. Loosen those screws and the bill path will hinge open. Using rubbing alcohol and cotton balls/Q-tips, clean the entire bill path, including the (2) silver heads, white nylon rollers, and the sensors. DO NOT CLEAN THE BELTS!! After cleaning, close the bill path and tighten the latch studs back up. (XE 101-0079 page 9) STA series: There are (2) slides on the validator, (1) on each side, sliding those back together the bill path will hinge open. Using rubbing alcohol and cotton balls/Q-tips, clean the entire bill path, including the (2) silver heads, white nylon rollers, belts, and the sensors. It’s ok to clean the belts on the STA validator. After cleaning, close the bill path, making sure the slides lock back into place (you will hear them snap when locked in place). How do I calibrate my validator? XE validator (2132) STA (2131) My validator flashes 1/2 of a o
be down. Please try the request again. Your cache administrator is webmaster. Generated Mon, 17 Oct 2016 12:25:44 GMT by s_wx1131 (squid/3.5.20)