Error Loading S8p File
it enabled. Please turn JavaScript back on and reload this page.More Discussions in 8-bit Microcontrollers Where is this place located?NXP CommunityAll Places8-bit MicrocontrollersLog in to create and rate content, and to follow, bookmark, and share content with other members.Prgarmming error of MC9S08GT60Discussion created by Praveen Devabattula on Jan 4, 2007Latest reply on Jan 5, 2007 by Michael Rhoades Like • Show 0 Likes0 Comment • 2 Hi,please find attachment freescale.bmpI am trying to program the MC9S08GT60 IC with cyclone pro withBDM connecter but the following error is shown while programming.Iused 9S08GT60.S8P and 9S08GT60A.S8Palgorithm file which I used for my programming. I tried with both of them.Message Edited by praveen on 2007-01-0404:28 AMMessage Edited by praveen on 2007-01-0404:30 AMOutcomesVisibility: 8-bit Microcontrollers1940 ViewsLast modified on Jan 4, 2007 5:27 AMThis content has been marked as final. Show 2 comments2 RepliesNameEmail AddressWebsite AddressName(Required)Email Address(Required, will not be published)Website AddressDavid Payne Jan 4, 2007 7:00 AMHi praveen,Firstly, there is no difference between the algorithm files for the GT60 and GT60A!Error 14 is described simply as Error Loading .S8P file. Which you already know.I think the problem is shown a few lines further up. The recommended trim is calculated as zero.This should not happen and the trim should be calculated even though the device is secure.Is it really secured?What is your clock source?RegardsPegLike • Show 0 Likes0 Actions Michael Rhoades Jan 5, 2007 4:01 PMpraveen -I'm trying to work through a similar problem here. I haven't been able to spend the time to completely investigate my problem, but here are some observations that might help you.Peg's hint about the trim value is helpful. Thetrim value of $00 that the P&E tool is calculating is really wrong. It is likely that the internal oscillator will not actually run with the $00 loaded into the TRIM register. This is why you get the error 14. When the S8P stuffs the the TRIM register with zeroes, the oscillator quits and the rest of the file can't run.This error in calculating the trim has to be due to the tool not reading the sync pulse properly. In my case, I have found that adding 10K external pull-ups to the BKGD pin and the reset pin solve my problem. (You are not supposed to have to use external pull-ups. I'm working on debugging a new S08 and this is probably only a workaround for some
application note describes how to perform a "Factory 2nd-tier calibration". Users who wish to perform regular (e.g. annual) in-house calibration of their SPARQ should use this procedure to generate a "factory" calibration file that is applied "on-top" of the automatic internal calibration. With the factory 2nd-tier calibration, users can perform a periodic calibration of their SPARQ that is a true calibration, as opposed to a typical "performance verification procedure", which is often performed on other test instruments but which only verifies performance. Additional FormatsPDF OverviewThe following procedure describes how to perform a Factory Second-tier Calibration. https://community.nxp.com/thread/22543 All SPARQ models that include the internal calibration capability (“E” Series SPARQs) are shipped with a factory 2nd -tier calibration, and the default SPARQ configuration enables the application of this calibration via a checkbox in the Calibration tab.Factory 2nd -tier calibrations are nominally performed on all SPARQ returned for an annual calibration, and on repairs that affect the signal path, including http://teledynelecroy.com/doc/docview.aspx?id=5815 internal switch matrix, pulser/sampler, sampler and/or cable. With the 2nd -tier calibration, the annual calibration is not simply a “performance verification”, but is instead a real calibration that corrects for any drift that may have occurred in the SPARQ’s signal paths prior to the last factory 2nd -tier calibration.End-users can also perform a factory 2nd -tier calibration at their discretion, and the scripts described in this document are available via download from the LeCroy website. By performing a factory 2nd -tier calibration, users have the ability to achieve the best performance possible short of a full recalibration of the SPARQ, which can only be done at the factory. A full recalibration includes re-measurement of the internal switch matrix on “E” Series SPARQ models.The goal of the factory 2nd -Tier calibration is to generate a calibration file that is applied “on top” of the automatic calibration performed by the internal OSLT calibration. The action of the 2nd -tier calibration should be small; the error corrections that applied should act as a fine-tuning of the measurement.Note: The Factory 2nd -tier c
This tool uses JavaScript and much of it will not work correctly without it enabled. Please turn JavaScript back on and reload this page. All Places > PCB Systems Design > HyperLynx - Simulation and High-Speed Design > SI, PI, Thermal, EMI/EMC, and DRC > Discussions Please enter a title. You can not post a blank message. Please type your message and try again. 4 Replies Latest reply on Dec 2, 2013 10:10 AM by patrick_carrier Query regarding conversion of 8-port single-ended S parameter model to 4-port mixed(or differential) mode S-parameter model adityanc Jul 5, 2013 5:53 AM HiI am using Hyperlynx line sim 8.2.1 version.In my cross talk simulation of two differential signals, I am able to export 8 x 8 single ended S-parameter model to a *.s8p file. After that when I load the file in touchstone, I am not able to convert the 8x8 Single ended model into a 4x4 differential mode S-parameter matrix.I tried converting a 4x4 single-ended S parameter model to a 2x2 mixed mode S-parameter model. For that it worked. The options got diaabled for 8x8 single ended S-parameter model.Why are the options disabled??regardsAditya.N.C I have the same question Show 0 Likes(0) 6279Views Tags: none (add) This content has been marked as final. Show 4 replies 1. Re: Query regarding conversion of 8-port single-ended S parameter model to 4-port mixed(or differential) mode S-parameter model cristian.filip Jul 5, 2013 6:04 AM (in response to adityanc) Hi Aditya,HyperLynx 8.2.1 does not support mode conversion for more than four SE ports. However you can do this in HSpice. For details and example netlist see the following link:http://communities.mentor.com/thread/10260?tstart=60Cheers,Cristian Like Show 0 Likes(0) Actions 2. Re: Query regarding conversion of 8-port single-ended S parameter model to 4-port mixed(or differential) mode S-parameter model patrick_carrier Jul 9, 2013 12:15 PM (in response to adityanc) We realize this is a useful feature and have it planned for an upcoming release.In the meantime, there is a workaround using Modua from HyperLynx 3D (which is part of the HyperLynx SI install). It does take some time to do the conversion, but it works.1. 1. Open Modua.exe from your HyperLynx install at …\SDD_HOME\IE3D\exe\ and then click Yes and OK.2. 2. Load in the S-parameter by Selecting File -> Open (and select All Files *.*).3. 3. Once loaded, select Process -> Differential Conversion. Wait for the next dialog to pop up.4. 4. Cl