I/o Error Abend B37-04
Contents |
Tech - Conferences [ September 22, 2016 ] GSE Management Summit in Lisbon, Portugal (26 – 27 Sep) Tech iec030i b37-04 - Conferences [ September 13, 2016 ] Using CLIST with RACF system abend code = b37, reason code = 00000004 SEARCH command JCL [ September 5, 2016 ] Useful Operator Commands to Manage a Parallel Sysplex Environment e37-04 JES Search for: HomeTech - MainframeMVSMost Common Out-Of-Space Abends and Error Codes Most Common Out-Of-Space Abends and Error Codes October 2, 2013 Rui Miguel Feio MVS, Storage, Tech
Ifg0554a
- Mainframe Although many other space related abends and error codes may occur, the truth is that some are more common than others. The following table lists the ones that fall under the most common out-of-space abends and error codes: Abend / Error Explanation B37-04 Insufficient space/extents on current volume and no additional volumes available B37-08 iec028i 837-08 VTOC (Volume Table Of Contents) conversion routine failed B37-0C Too many open datasets on device D37-04 No secondary space specified E37-04 No more volumes specified E37-08 No space available on new volume E37-0C DADSM (Direct Access Device Space Management) exit rejected extend IEC028I 837-08 Dataset allocation requires more than 5 volumes IEC070I 203-204 No secondary space specified IEC070I 104-034 Max extents or max RBA (Relative Byte Address) limit reached IEC070I 104-204 VSAM – Insufficient space on current volume and no additional volumes available or max extents reached IEC217I B14-0C There is no space left in the dataset directory, or there is no space left in the dataset for writing an EOF (End Of File) record Click to share on Facebook (Opens in new window)Click to share on LinkedIn (Opens in new window)Click to share on Twitter (Opens in new window)Click to share on Google+ (Opens in new window)Click to share on Reddit (Opens in new window)Click to email this to a friend (Opens in new window)Click
Disk space problem Below is a summary of the common messages that could occur. Each message is identified by a message number, and is formatted as: NNNNNNN ccc-rr jjj sss ddname where NNNNNNN is iec070i 209-220 the error message number ccc is the system completion code associated with the message
B37 Error
rr is the return code associated with the message jjj is the job name sss is the step name ddname is the
Iec032i
file associated with the problem Message Number Parameters/Description IEA702I 80A-1 There is not enough storage to run the request program IEA703I 806-x x=4 The requested program could not be found. Check the JCL STEPLIB http://ruifeio.com/2013/10/02/most-common-out-of-space-abends-and-error-codes/ or JOBLIB statements to be sure they define the library containing the requested program. x=8 An uncorrectable input-output error has occurred. Try to run the job again. If the error reoccurs, consult your technical support staff IEC015I A34-04 An attempt was made to read an unopened file. IEC020I 001-x x=1, 3, or 4 The dataset characteristics don't match the specified file. Check your FD, JCL and data set information x=2 An http://faculty.madisoncollege.edu/schmidt/mainframe/abendcodes.html error occurred when the program tried to close the file x=5 The program tried to read the file after end of file had been reached. IEC030I B37-04 There is no space left on the disk volume The data set has reached it's limit of space The disk volume table of contents is full IEC031I D37-04 The file has used up all of its space IEC032I E37-x x=04 All available disk space is used up IEC141I 013-x x=10, 34 The block size and record length are both 0 or the block size is not a multiple of the record length. x=20 The record format indicates that the file is a blocked file, but the block size is not a multiple of the record size. x=60 The record format indicates that the file is an unblocked file, but the block size does not equal the record length x=68 The block size exceeds the maximum allowable IEC143I 213-x x=04 1) An incorrect volume or data set name parameter 2) Data set not found on disk 3) The data set has been deleted x=08 Password violation x=18, 1C I/O error Common Completion Codes - Details Code Probable Cause 001 I/O Error Attempt to read after AT END Referring to an I/O area before opening and rea
productResults.length + resourceResults.length > 0 ? 'See all Search Results' : 'Full site search'}} > > CA Support Online > Support by Product > Support by Product Receiving a B37-04 error abend for ddname PRUWF2 when running the Prefix Resolution&Update Utility (PRU) with http://www.ca.com/us/support/ca-support-online/product-content/knowledgebase-articles/tec606714.aspx Logical Related Databases. Document ID:TEC606714 Last Modified Date:02/26/2014 {{active ? 'Hide' : http://mainframegeek.me/abend-codes-and-explanation/ 'Show'}} Technical Document Details Products CA Database Analyzer for IMS for z/OS CA Database Management Solutions for IMS for z/OS CA Database Organizer for IMS for z/OS Components CA Database Organizer for IMS:DBO Description: When executing PRU a B37-04 abend is being issued for DDNAME PRUWF2: i/o error IEC030I B37-04,IFG0554A,jobname,stepname,PRUWF2,VIO , ,dsname What is DD PRUWF2 and how do we resolve this B37 failure? Solution: The PRUWF2 file is a temporary work file allocated by PRU when we are not using a Dataspace. The file space allocation is based on the size of the SORTIN/DFSURWF1 input file. In the job control cards SMDSPACE=NO is specified. To resolve i/o error abend this error you have two options: Use a Dataspace by either specifying SMDSPACE=YES or by allowing PRU to default to SMDSPACE=YES by removing SMDSPACE=NO. Hard-code a PRUWF2 DD in the JCL (see sample JCL member JCLPRU5). Sample PRU JCL is provided in the highlevel.CIMTSAMP library. Members JCLPRU1-5 provide examples of using a DATASPACE and alternatively using a PRUWF2 DD; either by hard-coding in the JCL or through dynamic allocation. Please help us improve! Will this information enable you to resolve your issue? Yes No Please tell us what we can do better. {{feedbackText.length ? feedbackText.length : '0'}}/255 {{status}} Not what you were looking for? Search Again> Product Information Support by Product> Product Documentation> Communities Join a Community> Education Find training by product> SHARE THIS {{link.title}} Copyright © 2016 CA. All rights reserved. {{link.title}} North America (English) Chat with CA Just give us some brief information and we'll connect you to the right CA Expert. Our hours of availability are 8AM - 5PM CST. All Fields Required First Name Last Name Email Address
or worth reading for someone please like mainframegeek facebook page. Abend Codes Abend happens during the execution of a program in a step(JCL). Generally it can be categorized into system abend and user abend. System Abend - It will occurs when the system is not able to execute a statement which is coded in a program. This abend code will be thrown by OS. User Abend - This is due to unexpected condition occurs in data passed; this abend will be thrown by application based on the requirement. Condition Code Abends CC=0001 - (1016) PIE JOBS - BAD PART NUMBER - FOLLOW PACBOOK VERY CAREFULLY CC=001 - I/O ERROR CC=002 - I/O INVALID RECORD CC=0004 - DATASET NOT FOUND, TABLESPACE IN COPY PENDING, ETC MAY BE OK(CHECK COND STATEMENTS OR CALL ADM TO VERIFY) CC=0008 - EQUIP CHECK, UNABLE TO DBR DB RLAO00, RC-08 SQL ERROR, EMPTY DATASET CC=0010 - (CC=0016 IN HEX) BAD DATA CC=0012 - I/O ERROR TAPE, VSAM DATASETS CLOSED, INVALID DATA, EMPTY TABLE, COULD BE ANYTHING CC=0014 - CC=0016 - COULD BE ANYTHING, CONTENTION ,INVALID DATA, EMPTY TABLE, # OF FILES EXPECTED NOT EQUAL TO # OF FILES RECEIVED CC=0020 - COULD BE ANYTHING (CATCHALL) CC=0030 - DB2 TABLES WRONG DATES CC=0152 - ERROR ATTEMPTING TO TRANSLATE NEXT TRANSACTION CC=0696 - FTP LINE DOWN CC=804 OR 80A - REGION SIZE TOO SMALL - SPECIFY REGION=0M CC=1000 - BAD DATA, CONTENTION(-911) CC=1008 - TOTALS OUT OF BALANCE CC=1016 - NUMBER OF FILES EXPECTED DOES NOT EQUAL NUMBER RECEIVED, BAD DATA, CONTENTION CC=1999 - DATA EXCEPTION, BAD DATA CC=2000 - RESOURCE NOT FOUND (07D0), PROGRAMMING ERROR WAITING FOR FILE, RACF (-922), REBIND (-805) CC=2004 - CYCLE OUT OF SEQUENCE CC=2016 - TOO MUCH DATA FOR ARRAY SIZE, TABLE UPDATE INCORRECT, NULL DATA CC=2444 - INVALID RECORD LENGTH CC=8000 DATASET ALREADY IN USE, I/O ERROR, FILES NOT SENT RESOURCE NOT AVAILABLE CC=FFF - FATAL INTER ADDRESS COMMUNICATION ERROR User Abends U046 - NOT ENOUGH OR NO SORT WORK SPACE ALLOCATED. U048 - USER DOES NOT HAVE ACCESS AUTHORIZATION FOR THE DATASET U061 - REORDER DATASETS, CHECK BLOCKSIZES. LARGEST BLOCKSIZE FIRST U063 - CHECK SPELLING OF DD STATEMENTS U099 - DATASET NOT FOUND U0000 - DB2 STOPPED UTILID, TABLESPACE U0007/U0240 - VSAM I/O ERROR ON ACKS DATASET(WIDEBAND PROBLEM) U0100 - USER ERROR U0102 - PROBLEM WITH CHECKPOINT - MAY NOT HAVE BEEN ANY CHE