Ftp Winsock Error 10061
Contents |
an alternate FTP address. If you ftp socket error can connect to other FTP addresses, it is likely the site generating the error 10061 is how to fix socket error 10060 refusing to accept your connection because of security privileges or because it is not an FTP server.If you are unable to connect to any address, it is likely an issue with the
10061 Error
network or computer configuration. Ensure that the network configuration settings are properly setup as well as FTP rights. Verify that the computer and router firewall is properly setup to allow FTP access. Additional information See FTP definition for additional information and related links. Was this page useful? YesNo Feedback E-mail Share Print Search Recently added pages View all recent updates Useful links About Computer Hope Site Map Forum Contact Us How to Help Top 10 pages Follow us Facebook Twitter Google+ Pinterest YouTube RSS © 2016 Computer Hope Legal Disclaimer - Privacy Statement
the presence of firewall or anti-virus software on the local computer or network connection. Either can block the ports needed to make a successful FTP connection to the remote server. For a regular FTP session, either disable the firewall or
Socket Error 10061 Connection Refused
anti-virus software or configure them to allow CuteFTP to establish an FTP session over ports 20 socket error 10061 connection refused windows 7 and 21. Consult the documentation or help file for your specific firewall or antivirus software product for instructions. Usually the manufacturer of the tftpd error 10061 device or software will also have specific instructions available on their Web site. If you continue to receive the same error after insuring ports 20 and 21 are open, contact the administrator of the site you are trying to http://www.computerhope.com/issues/ch001248.htm connect to. For more error code information, refer to Knowledge Base article 10140 at http://kb.globalscape.com. WSAETIMEDOUT (10060) 10060 is a connection-timeout error that usually appears when the client does not receive a response from the server for a specific command. This error often occurs when you try to connect in PASV mode to a server that prefers PORT for data connections. If you see an error log similar to the one below, in the Site Properties of the problem http://help.globalscape.com/help/cuteftp8/Socket_errors_10060_10061_10064_10065.htm site, click the Type tab, then change the Data Connection Type to Use PORT. COMMAND:> PASV 227 Entering Passive Mode (xxx,xx,xxx,xx,x,xxx). COMMAND:> LIST STATUS:> Connecting ftp data socket xxx.xx.xxx.xx:xxxx... ERROR:> Can't connect to remote server. Socket error = #10060. ERROR:> Failed to establish data socket. If you still receive a 10060 error, the server may be trying to send a listing for a very large directory (with many thousands of files) causing the client to time-out while waiting. Try increasing the time-out value in the Global Options dialog box (Tools > Global Options > Transfer > Reconnect and resume in [ n ] seconds if nothing received ) to a higher value, such as 45 or 60 seconds. The connection fails due to an error or timeout. Verify that the destination IP address is correct. Increase the connection timeout threshold under Global Settings > Connection. Switch to the opposite data connection type (PASV or PORT) under Site Settings > Type tab. Verify that the problem is not local by trying to connect to an alternate server. If a server name was used, verify it resolves to the correct address. If using a local server table for server name resolution, check to see that it doesn't resolve to an obsolete address. Try pinging the address. (See Troubleshooting Tips for details.) If you are using a router, verify the router is up and running (
Studio 2015 products Visual Studio Team Services Visual Studio Code Visual Studio Dev Essentials Office Office Word/Excel/PowerPoint Microsoft Graph Outlook OneDrive/Sharepoint Skype Services Store Cortana Bing Application Insights Languages & platforms Xamarin https://msdn.microsoft.com/en-us/library/windows/desktop/ms740668(v=vs.85).aspx ASP.NET C++ TypeScript .NET - VB, C#, F# Server Windows Server SQL Server BizTalk Server SharePoint Dynamics Programs & communities Students Startups Forums MSDN Subscriber downloads Sign in Search Microsoft Search Windows https://kb.paessler.com/en/topic/333-how-do-i-solve-a-connection-refused-socket-error-10061-in-enterprise-console Dev Center Windows Dev Center Explore What’s new for Windows 10 Intro to Universal Windows Platform Coding challenges Develop for accessibility Build for enterprise Windows Store opportunities Docs Windows apps Get started error 10061 Design and UI Develop API reference Publish Monetize Promote Games Get started UI design Develop Publish Desktop Get started Design Develop API reference Test and deploy Compatibility Windows IoT Microsoft Edge Windows Holographic Downloads Samples Support Why Windows Dashboard Explore What’s new for Windows 10 Intro to Universal Windows Platform Coding challenges Develop for accessibility Build for enterprise Windows Store opportunities Docs Windows apps Get error 10061 connection started Design and UI Develop API reference Publish Monetize Promote Games Get started UI design Develop Publish Desktop Get started Design Develop API reference Test and deploy Compatibility Windows IoT Microsoft Edge Windows Holographic Downloads Samples Support Why Windows Dashboard Networking and Internet Windows Sockets 2 Winsock Reference Winsock Reference Windows Sockets Error Codes Windows Sockets Error Codes Windows Sockets Error Codes Socket Options Winsock IOCTLs Winsock Annexes Winsock Enumerations Winsock Functions Winsock Structures and Typedefs Winsock Tracing Events Winsock SPI Windows Sockets Error Codes TOC Collapse the table of content Expand the table of content This documentation is archived and is not being maintained. This documentation is archived and is not being maintained. Windows Sockets Error Codes Most Windows Sockets 2 functions do not return the specific cause of an error when the function returns. For information, see the Handling Winsock Errors topic. The WSAGetLastError function returns the last error that occurred for the calling thread. When a particular Windows Sockets function indicates an error has occurred, this function should be called immediately to retrieve the extended error code for the failing function call. These error codes and a short text desc
ease planning, as well. Free PRTG Download >> What is this? This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general. You are invited to get involved by asking and answering questions! Learn more Top Tags 5749× prtg 1842× snmp 1468× sensor 938× wmi 622× notifications 468× maps View all Tags How do I solve a Connection Refused Socket Error # 10061 in Enterprise Console? Votes:0 Your Vote: Up Down When I try to connect to PRTG via the Enterprise Console, the software displays a socket error number 10061 and I cannot connect. However, I can still login to the PRTG web interface. What settings do I have to change to solve this? Why does the connection not work? enterprise-console error gui login prtg server-administrator windows Created on Feb 3, 2010 9:00:13 AM by Daniel Zobel [Paessler Support] Last change on Dec 7, 2012 3:15:58 PM by Gerald Schoch [Paessler Support] Permalink 1 Reply Accepted Answer Votes:0 Your Vote: Up Down This article applies to PRTG Network Monitor 14 or later Solving Connection Refused Socket Error # 10061 in the Enterprise Console The Enterprise Console is a native Windows application and one of the interfaces that you can use to change settings and review monitoring data of your PRTG setup. In order to retrieve this data, the Enterprise Console must establish a connection to the PRTG Web Server. If you open the PRTG Enterprise Console and see a "socket error number 10061", this means that your Enterprise Console was not able to connect to the PRTG Web Server running on the PRTG Core Server. There can be several reasons for this. If you can still log into the PRTG Web Interface but get this error message using the Enterprise Console, the most common matter is non-matching settings of Web Server and Enterprise Console. Step 1: Viewing the Enterprise Console Settings From the Windows Start Menu, open the PRTG Enterprise Console application. From the menu, select File | Manage PRTG Server Connections. The Devices overview appears. On the left side, click on PRTG Server Connections. On the right side, select a server entry and click on the edit Edit button (the wrench symbol). You see the settings the Enterprise Console uses to connect to the PRTG Web