50.5 Fuser Error
Contents |
Account Login Shopping Cart My Account Checkout Home Troubleshooting 50.5 Fuser Error on LaserJet 4200 4240 4250 4300 4350 Email 50.5 Fuser Error on LaserJet 4200 4240 4250 4300 4350 If you see this error code 50.5 on an HP LaserJet 4200, 4240, 50.5 fuser error hp 4015 4250, 4300, or 4350 series printer, the fuser installed in the printer is 50.5 fuser error 4250 registering as an incorrect fuser for that model printer. The problem is HP makes 3 different fusers which look identical, 50.5 fuser error 4350 but the 3 fusers are not interchangeable between printer models. The outside plastic and metal frame look the same, but the inner wiring is different. If the incorrect fuser goes in, you can get 50.5 fuser error hp laserjet 4250 a 50.5 error (or a 13.20 error in some cases) when you power on the printer. The best way to determine which fuser you have is to pull the fuser out of your printer and check the barcode label on the fuser. If you don't know how to remove the fuser from your printer,it's not difficult -- see the removal instructions farther down the page. Once you have
50.5 Fuser Error 4300
the fuser out, check the fuser's barcode label for the part # and see if the part # matches with your model printer. On the barcode you will find an HP part #, check the part# on your fuser to see if it matches in the list below. If you have any questions give us a call toll-free 866-352-7108 or local 608-831-2396, we can help you get the right fuser for your specific model. part# RM1-0013 purchase HP 4200 fuser/maintenance kit here for use in HP LaserJet 4200, HP LaserJet 4200N, HP LaserJet 4200TN, HP LaserJet 4200DTN, HP LaserJet 4200DTNs, HP LaserJet 4200DTNsl part# RM1-1082 purchase HP 4240, 4250, 4350 fuser/maintenance kit here for use in HP LaserJet 4240, HP LaserJet 4240N, HP LaserJet 4250, HP LaserJet 4250N, HP LaserJet 4250DN, HP LaserJet 4250TN, HP LaserJet 4250DTN, HP LaserJet 4250DTNsl part# RM1-0101 purchase HP 4300 fuser/maintenance kit here for use in HP LaserJet 4300, HP LaserJet 4300N, HP LaserJet 4300DN, HP LaserJet 4300TN, HP LaserJet 4300DTN, HP LaserJet 4300DTNs, HP LaserJet 4300DTNsl Removal instructions: How to remove the fuser: Turn the printer off and unplug the power cord. The fuser might be hot if you have been using the pri
Printer Error inconsistent fuser Codes and Support Error: 50.5 FUSER ERROR Error Description: The fuser has experienced http://www.printertechs.com/printer-troubleshooting/367-50-5-error-on-laserjet-4200-4240-4250-4300-4350 a type-mismatch error. Solution: 1. Reinstall the fuser. Check the connector (J1901) between the fuser and the product. Replace the cable or fuser if the connector is https://www.orionmarket.com/product_error/13786/HP/HP-CP6015/50.5-fuser-error/ damaged. 2. Reconnect the connectors of the fuser control PCA (J303, J305), low-voltage power-supply unit (J6), and the DC controller PCA (J102, J207). 3. Replace the fuser. See Fuser on page 191. Call for Assistance 877-755-5300 Home About Us Contact Us Search Site Map Printers Supplies Accessories Parts Error Codes Login Shopping Cart Return Policy Privacy Policy Orion Printers and Parts 6030 Marshalee Dr. #257 Elkridge, Maryland 21075 (410) 540-9090 (877) 755-5300 © 2016 Orion Contracting Services. All Rights Reserved.
MFP Printer Error Codes and Support Error: 50.5 Fuser error Error Description: The fuser experienced a type-mismatch error. fuser error Solution: 1. Ensure that the fuser is the correct voltage. 2. Reinstall the fuser. Check the connector (J1901) between the fuser and the product. Replace the cable or fuser 50.5 fuser error if the connector is damaged. 3. Reconnect the connectors of the fuser control PCA (J303, J305), low-voltage power supply unit (J6), and the DC controller PCA (J102, J207). 4. Replace the fuser. See Fuser on page 233. Call for Assistance 877-755-5300 Home About Us Contact Us Search Site Map Printers Supplies Accessories Parts Error Codes Login Shopping Cart Return Policy Privacy Policy Orion Printers and Parts 6030 Marshalee Dr. #257 Elkridge, Maryland 21075 (410) 540-9090 (877) 755-5300 © 2016 Orion Contracting Services. All Rights Reserved.
Next → Fuser Error 50.xx HP Laserjet 4200, 4240, 4250, 4300, 4350, 4345MFP Posted on November 29, 2014 by HP Service Center Fuser Error 50.xx HP Laserjet 4200, 4240, 4250, 4300, 4350, 4345MFP 50.1 Fuser Error Description: Low temperature reading from Fusing Assembly. Solution: 1. Turn Printer off ans wait 2 minutes, restart printer. 2. Replace Fusing Assembly 3. Replace DC Controller 4. Replace power supply 50.2 Fuser Error Description: fuser warm up service,- Fusing Assembly is taking too long to reach proper temperature. Solution: 1. Turn Printer off and then turn back on.. 2. Replace Fusing Assembly 3. Replace DC Controller 4. Replace power supply 50.3 Fuser Error Description: Fuser over temperature - Fusing Assembly is exceeding proper temperature. (Too Hot) Solution: 1. Turn Printer off and wait 5 minutes letting fuser assembly too cool, then turn back on.. 2. Replace Fusing Assembly 3. Replace DC Controller 4. Replace power supply 50.4 Fuser Error Description: faulty fuser - fuser assembly is experiencing a defect withing the assembly circuits. Solution: 1. Turn Printer off then turn back on.. 2. Replace Fusing Assembly 3. Replace DC Controller 4. Replace power supply 50.5 Fuser Error Description: incorrect fuser is installe Solution: 1. Turn Printer off then turn back on.. 2. Verify fuser part number with proper HP Printer model. 3. Verify that the correct voltage fuser is installed.. 4. Replace Fusing Assembly with correct fuser assembly. 50.6 Fuser Error Description: open fuser circuit Solution: 1. Turn Printer off ans wait 2 minutes, restart printer. 2. Replace Fusing Assembly 3. Replace DC Controller 4. Replace power supply To schedule a service appointment: Titanium Print Solutions Customer Care (888) 380-8847 To schedule a service appointment online. Online service request This entry was posted in Uncategorized by HP Service Center. Bookmark the permalink. Leave a Reply Cancel reply Your email address will not be published. Required fields are marked *Comment Name * Email * Website Current ye@r * Leave this field empty Proudly powered by WordPress