Due To System Error Code 5
Contents |
'System error 5' 'System error 1114' IIS Technote (troubleshooting) Problem(Abstract) C# (or OLE DB, or ODBC) application is failing with could not be loaded due to system error code 193 either 'Specified driver could not be loaded due to system error 5' or
Driver Could Not Be Loaded Due To System Error Code 193
'Specified driver could not be loaded due to system error 1114' Cause 'System error 5' is a Windows driver could not be loaded due to system error code 126 permission issue, while 'System error 1114' is a DLL initialization error. In both cases, referring to db2cli.dll and db2odbc.dll. Either error means that the ID that the application is running under
Jandy Salt System Error Codes
does not have Read & Execute List Folder Contents Read permissions on SQLLIB and it's subdirectories. Diagnosing the problem C# (or OLE DB, or ODBC) application is failing with either 'Specified driver could not be loaded due to system error 5' or 'Specified driver could not be loaded due to system error 1114' This problem can also arise with the Microsoft system error codes linux Internet Information Server (IIS). Resolving the problem Grant the application UserID Read & Execute List Folder Contents Read permissions on SQLLIB and it's subdirectories. The UserID also needs the above permissions on all of the parent directories. Note that the permissions do not have to be inherited by the Child Objects. For example, if DB2 is installed to C:\Program Files\IBM\SQLLIB then the above permissions must be granted on C:\ C:\Program Files C:\Program Files\IBM C:\Program Files\IBM\SQLLIB The permissions do not need to be inherited to the Child Objects except for the SQLLIB directory. The permissions need to be granted on 'C;\Program Files\IBM', but not on any other sub-directory of 'C;\Program Files'. If Microsoft Internet Information Service (IIS) is the application, then the UserIDs include IUS* ASP* IWAM* If IIS is using dedicated application pools, then setting them to run as 'Local System" should grant the required permissions. Document information More support for: DB2 for Linux, UNIX and Windows 3rd Party Tools - Microsoft Products (Access/VB/VC++) Software version: 9.1, 9.5, 9.7 Operating system(s): Windows Software edition: Enterprise Server, Express, Personal, Personal Developer's, Workgroup Server Referenc
& Site Management Integration Options Developers eMail Components CloudLinux Extensions Extension Catalog Submit your Extension Plans & Pricing Support Resources FAQs Forums Knowledge Base Documentation Downloads Plesk University Release notes Blog Become
System Error 123
a Partner Russian German French Spanish Chinese Japanese Italian Language English Russian
Windows Error Code 126
German French Spanish Chinese Japanese Italian any Search Connection to MySQL database fails: "Specified driver could not be odbc driver could not be loaded due to system error code 126 loaded due to system error 5: Access is denied. (MySQL ODBC 5.1 Driver)" Article ID: 116136, created on May 21, 2013, last review on Apr 28, 2015 Applies to: http://www-01.ibm.com/support/docview.wss?uid=swg21403672 Plesk 12.0 for Windows Plesk 11.5 for Windows Plesk 10.4 for Windows Symptoms An attempt to connect to the MySQL database from ASP/ASP.NET/PHP scripts fails: Microsoft OLE DB Provider for ODBC Drivers error '80004005' Specified driver could not be loaded due to system error 5: Access is denied. (MySQL ODBC 5.1 Driver, C:\Program Files (x86)\MySQL\Connector ODBC 5.1\myodbc5.dll). Cause The problem https://kb.plesk.com/en/116136 is caused by an error in the product that leads to incorrect permissions being set on the MySQL ODBC driver, denying all access to the psacln group. Resolution The problem will be fixed in a future release of Parallels Plesk Panel. As Workaround: Manually adjust permissions on the C:\Program Files (x86)\MySQL\Connector ODBC 5.1 folder directory: - Remove "Deny all" for the psacln group. - Allow "Read & Execute" access for the psacln group. Search Words odbc windows plesk permission issue plesk windows backup Schemas validity error : Element 'sites' ODBC error 56797cefb1efc9130f7c48a7d1db0f0c a914db3fdc7a53ddcfd1b2db8f5a1b9c 85a92ca67f2200d36506862eaa6ed6b8 bd7fc88cf1b01f097749ae6f87272128 ed7be2b984f9c27de1d2dc349dc19c6d a766cea0c28e23e978fa78ef81918ab8 ff5a00b8ead2e480367b019417a04207 c796c01d6951fa24ed54c7f1111667c6 46a8e394d6fa13134808921036a34da8 Email subscription for changes to this article RSS subscription for changes to this article Save as PDF Was this article helpful? Tell us how we may improve it. No Yes University Training & Certification Product Expert Program Partners Become a Partner Company About Us Leadership Team Press Room Contact Us Keep in touch © 2016 Parallels IP Holdings GmbH. All rights reserved. Plesk and the Plesk logo are trademarks of Parallels IP Holdings GmbH. Terms and Conditions Privacy Policy Impressum Sitemap
have a legacy application that needs to use 32 ODBC. When I click on any demo System Data Source supplied in the http://sqlanywhere-forum.sap.com/questions/12403/odbc-driver-could-not-be-loaded-due-to-system-error-code-126 install I get the following error: Microsoft ODBC Administrator The setup routines for the SQL Anywhere 11 ODBC driver could not be loaded due to system error code 126: The specified http://community.teradata.com/t5/Connectivity/ODBC-Connection-Error-Specified-driver-could-not-be-loaded/m-p/48945 module could not be found. (D:\PROGRA~2\SQLANY~1\BIN32\dbodbc11.dll) It also seems to post a version of this message when I cancel the first but this seems to originate from Driver's ConfigDSN, or system error ConfigTranslator failed as this the message header. I have verified that this file does exist in the Bin32 directory. I have also verfied that the directory is in the system PATH. I can successfully do this from the 64Bit ODBC administrator however this does me no good. I have successfully started my database using "D:\Program Files\SQL Anywhere 11\Bin32\dbeng11.exe" 32-bit odbc system error code asked 26 Jun '12, 13:09 Joe Snyder 36●1●1●5 accept rate: 0% edited 27 Jun '12, 05:39 Breck Carter 26.2k●411●566●815 do you get the same error when you use c:\windows\syswow64\odbcad32.exe to set up the odbc connection. (27 Jun '12, 05:22) Tom Mangano flat view 2 Answers: active answersoldest answersnewest answerspopular answers 3 Try to insert the full path in the reg key HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ODBC\ODBCINST.INI\SQL Anywhere 11 Maybe the short filenames are disabled on your machine. permanent link answered 27 Jun '12, 05:23 Martin 8.5k●112●148●235 accept rate: 14% Thanks, that did the trick. How do you enable short filenames? (27 Jun '12, 09:58) Joe Snyder Replies hidden 1 By default your NTFS drives creates an 8.3 (8-character for the name and 3 for the extension) filename each time a long filename is created. This feature can be disable, to increase disk speed: •Click on Start, type cmd in the Search Bar> right click "Run as admininstrator". •Once the commnand prompt is opened type the command below: •fsutil behavior set disable8dot3 1 •Restart your PC (27 Jun '12, 12:19) Martin 1 @Martin: Just out
All communityThis categoryThis boardKnowledge baseUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. Showing results for Search instead for Did you mean: Teradata : Product Forums : Connectivity : ODBC Connection Error - Specified driver could not... Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Subscribe Printer Friendly Page Highlighted brydgesk Enthusiast Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Friend Report Inappropriate Content 04-03-2012 03:00 PM 04-03-2012 03:00 PM ODBC Connection Error - Specified driver could not be loaded I installed the most recent ODBC driver earlier today (Windows XP 32-bit, ODBC version 14.00.00.04), and immediately lost the ability to connect via ODBC, in Teradata SQL Assistant. The error I receive is: 160: Specified driver could not be loaded due to system error 126 (Teradata) I gave up on trying to troubleshoot this error, and uninstalled that ODBC driver, but still receive the error. Since then I have done many things, but still receive the error: Uninstalled all programs relating to teradata (utilities, ODBC driver, ICU, GSS, SQL Assistant, etc) Deleted Tdata32.dll, Tdatas32.dll, tdprsr32.dll, and terasso.dll in the WINDOWS\system32 folder Did a registry search for 'Teradata' and removed all references to Driver Version 14 Restarted Installed complete Teradata 13 TTU, including all utilities, ODBC driver, ICU, and GSS Created new ODBC entries using newly installed Teradata driver Copied dll's from "C:\Program Files\Teradata\Client\13.10\ODBC Driver for Teradata\Lib" to "C:\WINDOWS\system32" Restarted After all those steps, I still receive the same "driver could not be loaded" error. I've spent hours on this now and am getting frustrated. Any suggestions? Everyone's Tags (1): odbc 0 Kudos Reply All Forum Topics Previous Topic Next Topic 13 REPLIES brydgesk Enthusiast Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Friend Report Inappropriate Content 04-04-2012 06:51 AM 04-04-2012 06:51 AM Re: ODBC Connection Error - Specified driver could not be loaded UPDATE: I found the issue. The system PATH variable still had references to the Teradata/Client/14.00 ODBC driver, even after complete uninstallation. Perhaps the uninstallers need to be a bit more robust... 0 Kudos Reply trekker Fan Options Mark as New Bookmark Subscribe Subscribe to RS