Out Of Memory Error In Vbscript
here for a quick overview of the site Help Center Detailed answers to any questions you might have Meta Discuss the workings and microsoft vbscript runtime error '800a0007' out of memory policies of this site About Us Learn more about Stack Overflow the microsoft vbscript compilation error '800a03e9' out of memory company Business Learn more about hiring developers or posting ads with us Stack Overflow Questions Jobs Documentation Tags wmi repository Users Badges Ask Question x Dismiss Join the Stack Overflow Community Stack Overflow is a community of 6.2 million programmers, just like you, helping each other. Join them; it only takes a minute: Sign up Large VBScript array yields 'Out of Memory' error up vote 2 down vote favorite In Classic ASP (VBScript), if I try to create a large 2-dimensinal array, I get an "Out of Memory" error. For example, this DIM xxx : xxx = 10000 DIM yyy : yyy = 10000 REDIM aaa(xxx, yyy) Response.End yeilds this Microsoft VBScript runtime error '800a0007' Out of memory Is their another data structure I can use that will work, or some other workaround? (2010-01-27) UPDATE: Upon further investigation of this legacy code I'm working on, the array is sparse. In other words, only a portion of the array place holders are needed. Like this: aaa(0, 0) = 1.23 aaa(101,12) = 1.57 aaa(3020,1200) = 2.58 etc. I thought about changing things to store the values like this: aaa(count) = "xxx,yyy,val" and then using Split() to get val given x and y, but that requires a time-consuming loop through the array each time I know x and y. Is there a better solution? arrays asp-classic vbscript multidimensional-array out-of-memory share|improve this question edited Jan 27 '10 at 21:28 AnthonyWJones 145k22195274 asked Jan 26 '10 at 19:13 twh 52311 2 You'll need to give at least an example of what you want to do with this memory. Data structure depends on usage... –Dan McGrath Jan 26 '10 at 19:15 1 Are you expecting all elements to have some significant value or would the p
here for a quick overview of the site Help Center Detailed answers to any questions you might have Meta Discuss the workings and policies of this site About Us Learn more about Stack Overflow the company Business Learn more about hiring developers or posting ads with us Stack Overflow Questions Jobs Documentation Tags Users Badges Ask Question x Dismiss Join the Stack Overflow Community Stack Overflow is a community of 6.2 million programmers, just like you, helping each other. Join http://stackoverflow.com/questions/2141904/large-vbscript-array-yields-out-of-memory-error them; it only takes a minute: Sign up Out of memory error in vbs scripts up vote 1 down vote favorite I've been facing this dialogue box just after I start my script Script: C:\konica.vbs Line: 14 Char: 1 Error: Out of Memory: 'GetObject' Code: 800A0007 Source: Microsoft VBScript runtime error This is my script: Set wshShell = CreateObject("WScript.Shell") strCurrDir http://stackoverflow.com/questions/34040581/out-of-memory-error-in-vbs-scripts = Replace(WScript.ScriptFullName, WScript.ScriptName, "") '### Konica ### strIPAddress = "192.168.110.168" strComputer = "." strPrinterName = "Konica" strDriverName = "KONICA MINOLTA C353 Series PS" strLocation = "Konica" strInfFile = "\\stp\HHard\Printers\KONICA MINOLTA\XP(x86)\BHC353PSWinx86_6500RU\BHC353PSWinx86_6500RU\KOAZXA__.INF" Set objWMIService = GetObject("winmgmts:{impersonationLevel=impersonate,(LoadDriver)}!\\" & strComputer & "\root\cimv2") Set colPrinters = objWMIService.ExecQuery("Select * From Win32_Printer Where PortName = 'IP_" & strIPAddress & "' ") For Each objPrinter in colPrinters MsgBox "Unable to install printer, printer already found on port 'IP_" & strIPAddress & "'." & VbCrlf & VbCrlf & "Found: " & objPrinter.DeviceID, vbExclamation + vbSystemModal, "Printer Port already assigned" WSCript.Quit 114001 Next 'MsgBox(strIPAddress) Set objNewPort = objWMIService.Get("Win32_TCPIPPrinterPort").SpawnInstance_ objNewPort.Name = "IP_" & strIPAddress objNewPort.Protocol = 1 objNewPort.HostAddress = strIPAddress objNewPort.PortNumber = "9100" objNewPort.SNMPEnabled = False objNewPort.Put_ wshShell.Run "rundll32 printui.dll,PrintUIEntry /if /b """ & strPrinterName & """ /f """ & strInfFile & """ /r ""IP_" & strIPAddress & """ /m """ & strDriverName & """", 1, True Set colPrinters = objWMIService.ExecQuery("Select * From Win32_Printer Where DeviceID = '" & strPrinterName & "' ") For Each objPrinter in colPrinters objPrinter.Location = strLocation objPrinter.Put_ Next You can see, tha
OnyxPhoenix99 Total Posts : 3 Scores: 0 Reward points : 0 Joined: 12/18/2013 Status: offline VBScript Runtime Error, Out of Memory: " " Code: 800A0007 Monday, December 30, 2013 http://www.visualbasicscript.com/VBScript-Runtime-Error-Out-of-Memory-quot-quot-Code-800A0007-m103863.aspx 2:29 AM (permalink) 0 Hello Superior Scriptors, We have been experiencing the following runtime error: Error: Out of Memory: ‘GetObject’ Code: 800A0007 Source: Microsoft VBScript runtime error I have searched Visualbasicscript.com and quite a http://www.vbforums.com/showthread.php?734969-Code-800A0007-Out-of-Memory-Error few other forums looking for an explanation and solution to the above runtime error. I reviewed “VBScript SubFolder "Out of Memory" 800A0007 when running against large…” thread suggesting that the error could be out of related to an infinite loop. This seems consistent with a thread in another forum about frame building; however, the initiator of the post never posted whether the suggested fixes to his script resolved the problem. For the sake of simplicity, I have found a short script that produces the same error we have been encountering on machines. It appears that the error is produced anytime a script attempts out of memory to connect to the wmimgmts console. Below is a script I found to produce the same error. The script is entitled “DisplayProcessInformation.vbs” I have run it in Wscript and Cscript using the CMDlet with the same results. I have also placed it on my desktop and in the Documents directory with the same results. Another observation that I have noticed is that I can restart the machine and run the script successfully within the first ten minutes of reboot. After ten or so minutes the script will give the error. I have checked Processes for multiple instances of wscript.exe or any other WSH process that may be running and nothing jumps out at me off hand. I see no apparent memory leaks and have almost seven of eight gigs of memory after the machines has completely loaded. The script: Option Explicit 'On Error Resume Next Dim objWMIService, WshShell Dim objItem Dim i Const MAX_LOOPS = 2, QUARTER_HOUR = 900000 For i = 1 To MAX_LOOPS Set objWMIService = GetObject("winmgmts:").ExecQuery _ ("SELECT * FROM Win32_Process where processID <> 0") Set WshShell = CreateObject("WScript.Shell") WScript.Echo "There are " & objWMIService.count &_ " processes runni
is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. Results 1 to 2 of 2 Thread: Code 800A0007 Out of Memory Error Tweet Thread Tools Show Printable Version Subscribe to this Thread… Display Linear Mode Switch to Hybrid Mode Switch to Threaded Mode Sep 18th, 2013,04:05 PM #1 excelnewbie View Profile View Forum Posts Thread Starter New Member Join Date Sep 2013 Posts 1 Code 800A0007 Out of Memory Error Hello everyone, as I'm new to this forum and can not seem to find a response which helps me in answering my question. I"ve created a VB Script (.vbs file) code per below to read a text file and write/modify any specific word from this text file to another word then save and close. I've tested in a small set of data (around 20 rows of records and the code works) but when I implemented to the actual text file which is around 400,000 KB, I receive the following error message. Script: W:\Processing\Batch\HIRVABDetailCW.vbs LIne: 9 Char: 1 Error: OUt of memory Code: 800A0007 Source: Microsoft VBScript runtime error Code: Const ForReading = 1 Const ForWriting = 2 Const FileIn = "C:\Documents and Settings\NAME\AB_Current_Week.txt" Const FileOut = "C:\Documents and Settings\NAME\AB_Current_Week.txt" '<== Change to prevent overwrite of original file Set objFSO = CreateObject("Scripting.FileSystemObject") Set objFile = objFSO.OpenTextFile(FileIn, ForReading) strText = objFile.ReadAll objFile.Close strNewText = Replace(strText, "HIRV 13", "HIRV 14") Set objFile = objFSO.OpenTextFile(FileOut, ForWriting) objFile.WriteLine strNewText objFile.Close Any help you can provide will be much appreciated. Thank you. Reply With Quote Sep 18th, 2013,10:29 PM #2 Bonnie West View Profile View Forum Posts Visit Homepage Default Member Join Date Jun 2012 Location InIDE Posts 4,057 Re: Code 800A0007 Out of Memory Error Originally Posted by excelnewbie ... but when I implemented to the actual text file which is around 400,000 KB, I receive the following error message. Error: OUt of memory You're attempting to read about 390 MB of text into RAM all at once? If your system doesn't have enough memory to satisfy such request, you'll definitely be getting that error. However, even if your system is capable of such feat, it still isn't a recommended way of reading files. I suggest that you read and write the text line by line like this: Code: Option Explicit Const FileIn = "C: