Input Lost Join Sign in Poweredge 2900 III - Input Lost Servers Information and ideas on Dell PowerEdge rack, tower and blade server solutions. Get dell poweredge 2900 error codes this RSS feed Home Forums Server Media Gallery 7 Replies 1 Subscriber Postedover dell poweredge 2900 manual 8 years ago Poweredge 2900 III - Input Lost Posted by itssm on 26 Mar 2008 9:19 HiCan anyone dell poweredge 2900 drivers advise what the following messages mean please? I've just had a call to say there are some messages on the LCD display of the server. PS1 Input Lost E1624 PS Redundancy dell poweredge 2900 hard drive Power Edge 2900 E1614 PS 1 Status E161C PS1 Input Lost. I'm guessing it means the 1st power supply has gone down. I'm not sure if it was giving out this message before we installed a UPS the other day. Could the installation of the UPS cause this message to show? I'm thinking the system is thinking there is no power to it. Like 0 Reply
Dell Poweredge 2900 Price
You have posted to a forum that requires a moderator to approve posts before they are publicly available. Posted by pcmeiners on 26 Mar 2008 13:21 "Could the installation of the UPS cause this message to show?"It could if the UPS is not working correctly, or more likely, if a power fault occurred before the UPS batteries were fully charged. Another possibility, the particular power supply is very sensitive to power fluctuations when the BBU goes to battery; on the units I have used, the line voltage is generally slightly higher then the output of the BBUs when running on battery. A normal power supply (within specifications) should be able to handle normal power fluctuations without going into an error state. Like 0 Reply You have posted to a forum that requires a moderator to approve posts before they are publicly available. Posted by itssm on 26 Mar 2008 13:53 Thanks for your reply. What would you suggest I do? I guess the first test would be to shut the server down and remove the UPS. If the error message goes then that would suggest it's the UPS that is faulty (or
Favorite Rating: Interpreting the error codes displayed on the system LCD screen
Dell Poweredge 2900 Weight
of the Forge applianceThis document (7921054) is provided subject to dell poweredge 2900 release date the disclaimer at the end of this document. Environment Forge 1.0 and higher Situation The following dell poweredge 2900 power supply articleprovides definitions of the error codes displayed on PlateSpin Forge appliance system LCD screen. The error codes and their definitions are separated into categoriesdepending on the http://en.community.dell.com/support-forums/servers/f/956/t/18940287 source of the error.Cable and Board Presence - Message Code: "x1Axx" Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD System Phase When Event Can Occur? E1A10 PDBPwrCable High PDB power cable to the planar is missing or bad and system will not power on. https://www.novell.com/support/kb/doc.php?id=7921054 Failing device is reseated/replaced/repaired. Pre-Post E1A11 PCIRsrConfig High PCI risers are not configured correctly; some invalid configurations prevent system power on. Failing device is reseated/replaced/repaired. Pre-Post E1A12 PCIRsrMissing High One or all of the PCI risers is missing. This prevents system power on. Failing device is reseated/replaced/repaired. Pre-Post E1A14 SAS Cable A Low SAS cable A is missing or bad. Failing device is reseated/replaced/repaired. Any E1A15 SAS Cable B Low SAS cable B is missing or bad. Failing device is reseated/replaced/repaired. Any E1A16 SAS Cable FB Low Flex bay SAS cable is missing or bad. Failing device is reseated/replaced/repaired. Any E1A17 PwrCable FB Low Flex bay power cable is missing or bad. Failing device is reseated/replaced/repaired. Any E1A18 PDBCtrl Cable High PDB control cable to the planar is missing or bad and system will not power on. Failing device is reseated/replaced/repaired. Any Temperature - Message Code: "x11xx" Message Code Message String Message Priority Me
Indicator Codes NIC Indicator Codes LCD Status Messages System Messages Warning Messages Diagnostics Messages Alert Messages This section describes the physical, firmware, and http://www.serwerydell.eu/2950/it/about.htm software interface features that provide and ensure the essential functioning of your system. The physical connectors on your system's front and back panels provide convenient connectivity and https://www.manualowl.com/m/Dell/PowerEdge-2900/Manual/189132?page=21 system expansion capability. The system firmware, applications, and operating systems monitor the system and component status and alert you when a problem arises. System conditions can dell poweredge be reported by any of the following: Front or back panel indicatorsSystem messagesWarning messagesDiagnostics messagesAlert messages This section describes each type of message, lists the possible causes, and provides steps to resolve any problems indicated by a message. The system indicators and features are illustrated in this section. Other Information You May Need CAUTION: dell poweredge 2900 The Product Information Guide provides important safety and regulatory information. Warranty information may be included within this document or as a separate document. The Rack Installation Guide or Rack Installation Instructions included with your rack solution describes how to install your system into a rack.The Getting Started Guide provides an overview of system features, setting up your system, and technical specifications.CDs included with your system provide documentation and tools for configuring and managing your system.Systems management software documentation describes the features, requirements, installation, and basic operation of the software. Operating system documentation describes how to install (if necessary), configure, and use the operating system software.Documentation for any components you purchased separately provides information to configure and install these options.Updates are sometimes included with the system to describe changes to the system, software, and/or documentation. NOTE: Always check for updates on support.dell.com and read the updates first because they often supersede information in other documents. Release notes or readme files may
Add to My Manuals! Save this manual to your list of manuals Page 21 highlightsTable 1-6. Code E1422 E1610 LCD Status Messages (continued) Text CPU Machine Chk PS # Missing Causes The system BIOS has reported a machine check error. Corrective Actions See "Getting Help" on page 147. No power is available from the See "Troubleshooting Power specified power supply; specified Supplies" on page 122. power supply is improperly installed or faulty. No power is available from the See "Troubleshooting Power specified power supply; specified Supplies" on page 122. power supply is improperly installed or faulty. Power supply voltage is out of See "Troubleshooting Power acceptable range; specified power Supplies" on page 122. supply is improperly installed or faulty. Power source for specified power Check the AC power source for supply is unavailable, or out of the specified power supply. If acceptable range problem persists, see "Troubleshooting Power Supplies" on page 122. E1614 PS # Status E1618 PS # Predictive E161C PS # Input Lost E1620 PS # Input Range Power source for specified power Check the AC power source for supply is unavailable, or out of the specified power supply. If acceptable range problem persists, see "Troubleshooting Power Supplies" on page 122. PS Redundancy The power supply subsystem is no See "Troubleshooting Power Supplies" on page 122. longer redundant. If the last supply fails, the system will go down. The system BIOS has reported an See "Getting Help" on page 147. I/O channel check error. Remove and reseat the PCI expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 131. E1624 E1710 E1711 I/O Channel Chk PCI PERR B## D## The system BIOS has reported a F## PCI parity error on a component PCI PERR Slot # that resides in PCI configuration space at bus ##, device ##, function ##. If the problem persists, the The system BIOS has reported a system board is faulty. See PCI parity error on a component "Getting Help" on page 147. that resides in PCI slot #. About Your System 21 Type your new search above The manual viewer requires the flash plugin to be installed and enabled. To view this page ensure that Adobe Flash Player version 10 or greater is installed. Dell PowerEdge 2900 Manual All contents © copyright 2009 - 2016, ManualOwl.com Trademarks and brands are the prope